Hilmerson Safety Safety Rail System Скачать руководство пользователя страница 11

11 

*Approved fall protection must be utilized while installing bases and guardrails where fall hazards exist. 

Installing Guardrail Panels 

   

 

 

 
 

 

 
 

 
 

 

 

 

 

3.

 

Install a gravity-locking pin 
through the base plate post 

and guardrail panel, making 
sure that the loop on the pin 

falls into the locked position. 

 
 
 
 
 
 
 
 

4.

 

When installing guardrail 
panels on bases at corners, 

situate bases at 45 degree 
angles to allow full pin 

engagement and secure 
locking.  

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

   

 

 

 

   

 

 

 

Содержание Safety Rail System

Страница 1: ...merson Safety Rail System poses a threat to safety and health and may result in death or serious injury to installers users and or third parties Hilmerson Safety and our manufacturer expressly disclai...

Страница 2: ...deck that changes location as additional floor roof or deck or formwork sections are placed or constructed A leading edge is considered an unprotected side and edge OUTRIGGER RETURN A 5 ft or 10 ft gu...

Страница 3: ...nstalled on is capable of supporting the product and personnel installing it A complete assessment of the entire surrounding areas should be made to determine if the walking and working surfaces have...

Страница 4: ...nel 5 5 ft 9ft Adjustable 1 O D x Galvanized 13 gage tube Warning It is recommended that a competent person approve and oversee the installation of this system The Hilmerson Safety Rail System is an e...

Страница 5: ...ade 50 Steel Galvanized E HLM GRBPG Penetrating Anchored Base Plate ASTM A572 Grade 50 Steel Galvanized F HLM GRBPDL Weighted Base Dolly 1 O D x Galvanized 13 gage tube Powder Coated G HLM RS3G 22 34...

Страница 6: ...he desired protection layout before beginning the installation process 3 All guardrail layouts must be designed or approved by a competent person 4 When using penetrating anchored base plates anchor b...

Страница 7: ...gth of f c 3 000 psi normal weight cracked concrete Non penetrating weighted bases are recommended for use on post tension decks or other surfaces where you can t penetrate 2 Pre drill a diameter hole...

Страница 8: ...n 418072 through the top of the base plate and into the pre drilled hole according to Hilti p n 418072 x 3 KWIK HUS EZ KH EZ installation requirements 2 Tighten the anchor bolt until it is seated on...

Страница 9: ...to set up guardrail protection on a wide variety of surfaces but shall be no closer than 18 inches from the leading edge requiring protection unless there is an elevated parapet wall 2 Install only o...

Страница 10: ...hazards exist Installing Guardrail Panels 1 To install guardrail panels on either type of baseplate simply remove a guardrail panel from the mobile cart and seat on the base plate post 2 When seating...

Страница 11: ...stalling Guardrail Panels 3 Install a gravity locking pin through the base plate post and guardrail panel making sure that the loop on the pin falls into the locked position 4 When installing guardrai...

Страница 12: ...return guardrail panels and weighted bases are required to be installed perpendicular to the leading edge at the end of each protection run to provide required counterweight 2 Upon completion of insta...

Страница 13: ...re accurate to a degree consistent with current practice s Hilmerson Safety Services Inc and its affiliates do not assume responsibility for errors or oversights that may result from the use of the in...

Отзывы: