Normal Operation:
The pump will run when the trigger is pulled and stop when it is released.
The newly designed CC17 gun dispenses water from the left nozzle tip and soap from the right. To dispense soap, release
trigger, tilt gun to the left and squeeze the trigger. At this point, you can freely move the gun any way you choose as long
as the trigger is still depressed and only dispense soap from the right nozzle. The pressure of the application holds the
ball valve in place.
To switch to water, release the trigger, tilt the gun to the right and squeeze the trigger again. Now you are dispensing
only fresh water through the left nozzle tip.
The CC17 is designed to apply soap at low pressure from the #10 tip. High pressure rinse comes from the #3.5 tip.
Before putting the unit away after use, dispense fresh water through the gun one to two minutes to purge all chemical
from the lines and nozzle tips.
The pump will run approximately three hours on a fully charged battery.
Charging your Trident CC17XP:
The charger will recharge a fully discharged battery overnight (10-12 hours).
To charge, plug the power cord extending from the lower rear of the machine to a wall outlet. The charger is built in to
the unit and permanently housed in the chassis.
The battery charge indicator on the dashboard will complete a half circle when fully charged.
Always keeps the unit plugged in when not in use. You can not overcharge the battery and this practice will extend the
life of the battery.
Maintenance:
Daily:
1)
Run one to two gallons of fresh water through the unit after use. This will purge the lines and gun of any residual
chemical.
2)
Flip the power switch to the off position. Relieve the pressure in the discharge hose by pulling the trigger on the
application gun, once the machine is switched off.
3)
Check the unit for any visible damage or leaking.
4)
Charge when not in use.
5)
If the unit is stored where there is a possibility of freezing temperatures, drain the water reservoir and run the
pump until all water is purged from the system. Allow the unit to thaw before engaging the pump again.
Содержание TRIDENT CC17XP
Страница 1: ...Use and Maintenance manual CC17XP...