Hillstone SG-6000 Series Firewall Appliance Installation Manual
connector connected to a laser.
Connecting AC Power Cable
The AC power cable is shipped with the chassis. Prepare a single-phase three-terminal power
socket with a ground contact in advance. Normally, the ground contact of the power supply
system in a building was buried during construction and cabling. Before connecting the AC
input power cable, you must make sure that the power socket is well grounded.
To connect the AC power cable:
1.
Make sure the ground wire is reliably connected to the earth ground.
2.
Make sure the power switch of the appliance is in the OFF position.
3.
Connect the AC power socket of the power source using the AC power cable. To
connect more cables, repeat this step.
4.
Power on the switch of the appliance.
5.
Check PWR LED on the front panel. A shining LED indicates correct connection.
Note
: If a product does not have a power switch, you can skip Step2 and Step4.
Connecting DC Power Cable
To power the appliance with DC power source, use DC power cables to connect the appliance
and the external DC power source. Hillstone does not provide DC power cables.
Warning
: Before performing the procedure, ensure that the cable is not connected with any
power source and make sure the cables will not be powered on during the process.
To connect the DC power cable to the appliance:
1.
Ensure that the power source voltage is in accordance with required voltage specified
in
System Parameters
.
2.
Switch off the power source.
3.
If the terminal on the power supply module has a plastic cover, remove the cover and
keep it.
4.
Connect the grounding screw (labeled with “ ”) to the ground contact point using a
grounding wire.
- 33 -