SENSOR BULB FOR HOT GAS
DEFROST TERMINATION
CONTROL
3
20
DEFROST
AND
TEMP CONTROL
It is important to consult the control
setting guidelines shown on page 19 before
setting defrost times. Further adjustments
may be required depending on store condi-
tions.
This case is equipped with either
electric or hot gas defrost at the owners option.
The temperature control and defrost termination
control thermostats are located in the electrical
raceway as shown in diagram
1
below. The
temperature control and the electric defrost ter-
mination control sensor bulbs are located in
the rear wall behind the 3 1/2” plug button as
shown in diagram
2
. The hot gas defrost termi-
nation control sensor bulb is attached to the
dump line, diagram
3
, which is located inside
the tank.
TEMPERATURE CONTROL AND
DEFROST TERMINATION CONTROL
THERMOSTATS
SENSOR BULB FOR TEMPERATURE
CONTROL AND ELECTRIC DEFROST
TERMINATION CONTROL THERMOSTATS