Post-Record
: The time you set to record after the event or the scheduled time. For example, when an
alarm triggered recording ends at 11:00, if you set the post-record time as 5 seconds, it records till
11:00:05.
•
Expired Time
: The expired time is the longest time for a record file to be kept in the HDD, if the
deadline is reached, the file will be deleted. You can set the expired time to 0, and then the file will not
be deleted. The actual keeping time for the file should be determined by the capacity of the HDD..
•
Record Audio
: Check the checkbox to enable or disable audio recording.
•
Video Stream
: Main stream and sub-stream are selectable for recording. When you select sub-stream,
you can record for a longer time with the same storage space.
•
Click
Apply
to save the settings.
You can enable the ANR (Automatic Network Replenishment) function via the Web browser
(
Configuration
>
Storage
>
Schedule Settings
>
Advanced
) to save the video files in the IP camera
when the network is disconnected, and synchronize the files to the DVR when the network is
resumed.
The parameters of Main Stream (Event) are read-only.
•
Parameter Settings for Sub-stream
•
Enter the Sub-stream tab page.
Sub-stream Parameters
•
Configure the camera parameters.
•
Click
Apply
to save the settings.