EN50131-2-2:2008
EN50131-1:2006+A1:2009
Environmental Class (EC) II
Security Grade (SG) 2
DS-PD2-P10P-W
Wireless 10m Pet Immune PIR Detector
DS-PWA32-HR
Wireless Security Control Panel
A
B
C
CEILINGBRACKET
<24kg
2m
1m
3m 4m 5m 6m 7m 8m 9m
9m
8m
7m
6m
5m
4m
3m
2m
1m
10m
10m
8m 9m
10m
2.4m
2m
1m
3m 4m 5m 6m 7m
HORIZONTAL COVERAGE
VERTICAL COVERAGE
85
56 ZONES
6 PLANES
°
Diagram References
The batteries supplied have been chosen to provide long service life
whilst, for safety reasons, having limited output current.The battery is
protected on purchase by a piece of plastic that must be removed for
operation. When disposing of the product, the battery must be removed
and disposed of separately in accordance with the local regulations.
Specification
Battery Information
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
This
product
and -
if
applicable
- the
supplied
accessories too are
marked with "CE" and c
omply
t
herefore w
ith th
e applicable h
armonized
Eu
ropean s
tandards listed und
er the RE Directive 2014/53/EU,
the RoHS Directive 2011/65/
E
U.
For electrical products sold within the European
Community. At the end of the electrical products
lif
e
, it should not be disposed of with household
waste. Please recycle where facilities exist. Check
with your local Authority or retailer for recycling
advice in your country.
+
-
>5s
+
-
REGISTRATION
+
-
<24kg
>24kg
5s
+
-
LED ON
LED OFF
LOW
HIGH
+
+
+
+
+
+
+
+
CR123A
LITHIUM
-
HIGH
LOW
TAMPER
=
=
REGISTRATION
BRACKET TAMPER
SEE SECTION4
A
B
E
C
D
WALLBRACKET
Add Locally
1. Make the security control panel enter the registration mode.
2.Add the detector: Hold the registration key until the three LEDs flash
alternately.The green LED will flash 8 times if the registration is finished.
3. Communication Test: Release the TAMPER spring to trigger the alarm.
Note:
The di
stance between the security control panel and the detector
should be less than 50 cm.
Initialize the Detector
1.Remove the battery to power the detector off.
2. 5s later,hold the registration key and reinstall the battery to power the
detector on at the same time to make the three LEDs start flashing alternately.
Release the registration key while the three LEDs flash once together.
REAR TAMPER
BREAK-OUT
1
3
4
2
1
3
4
Diagnostics
(Check Signal Strength
Before
Mounting)
Bracket Wiring
Wireless device control
Please register the detector within 90 seconds after it being powered on.
3
4
1
2
Registration
E N G L I S H
Diagram References
E N G L I S H
23
24
25
26
Tear off
Cable Pipe
Cable Pipe
Cable Pipe
Cable Pipe
2
2
2
7
Detec
ti
on Range
10m
Detec
ti
on Angle
85°
Detec
ti
on Zones
56 zones and 6
p
lanes
Detec
ti
on S
p
eed
0.3–3.0 m
/
s
M
oun
ti
ng Height
1.8-2.4m
Animal Immunity
24kg
Blue Wave Technology
Su
pp
orted
Digital Tem
p
erature
Com
p
ensa
ti
on
Su
pp
orted
Tam
p
er Protec
ti
on
Front, rear, and bracket tam
p
er
signal in
p
ut
Signal Strength Indicators (SSI) Su
pp
orted
Frequency
433/
868
M
Hz
M
odula
ti
on
2GFSK
Range in o
p
en s
p
ace
800m
3V lithium ba
tt
ery included
1
x
CR123A
General ba
tt
ery li
f
e (years)
2
O
p
era
ti
ng | storage
-10°C to +40°C (Cer
tifi
ed)
Weight
125g
Dimensions(H
x
W
x
D)
117
x
69
x
50mm
Ceiling
M
ounted Bracket
Su
pp
orted
Wall
M
ounted Bracket
Su
pp
orted
Lens characteris
ti
cs
Key features
Other details
Accessories
Electrical speci
fi
ca
ti
ons
Wireless
Make sure the LED keeps green at the installation position when the detector is in
the signal strength mode before mounting.
2
21
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
2
10
2
11
2
12
22
Appearance
Installation
Set up via APP
Log Into the Web Client
Set Up
1
2
3
Set up via Web Client
AC Power
Power On
System Fault
No Fault
Panel is added to
Hik-connect account
Panel is not added to
Hik-connect account
Armed
Disarmed
Alarm Occurred
Device Tampered
No Alarm
Power Off
Fault
Link
Arm
/Disarm
Alarm
Note: Remove the rear cover, and some of the components and interfaces are on the rear panel.
2
1
2
2
2
3
2
5
2
4
1. Loosen the screw on the rear cover. Slide down the rear cover and remove it from the
control panel.
2. Insert a SIM card into the SIM card slot.
3. Connect the battery to the control panel.
4. Connect the power adapter to the control panel and a power outlet. The power indicator
turns green about 30s later, which means that the device is powered on.
Note: The condition of no SIM card, no battery, AC power off, or network disconnected, will cause Control Panel Fault.
5. Connect the Ethernet cable to an internet outlet. While the device is added to a Hik-Connect
account, the link indicator turns green.
6. Secure the rear cover in the installation position with the supplied screws. Attach the
control panel on the rear cover, and tighten the rear cover screw to complete the installation.
Side Opening
If you need to route the cable though the botton of the panel, remove the sheet of the side
opening.
1.
Log into the App Store or Google Play and input Hik-Connect to search and install the
mobile client.
2. Log into the APP with Hi-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).
4. Tap Connect to a Network. Select Wireless Connection (AP) as the connection mode.
5. Push the AP/STA mode switch to the AP position, tab Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and
click Next.
7. Create a password to activate the device.
8. Push the AP/STA mode switch to the STA position.
Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before
activation if you add the device by entering the device serial No.(SN).
SIM Card Slot
Battery Connector
Network Interface
Power Interface
Reset Button
AP&STA Switch
Tamper Spring
2
12
2
11
2
10
2
9
2
8
2
7
2
6
Note: The function of GPRS or 3/4G(implemented with build-in SIM card slot) depends on the model of the device.
TAMPER Screw
It is compulsory to secure the TAMPER screw.
Specification
Alarm In
p
ut
32
Alarm Out
p
ut
32
Siren
2
Key
f
ob
8
Par
titi
on
1
Interac
ti
on
Audio Out
p
ut
1, 1.5W
RF Frequency
433
/
868
M
Hz
RF
M
odula
ti
on
2GFSK
RF Distance
800m
(
O
p
en Area
)
Wired Network
Ethernet
10
M/
100
M
Sel
f
-ada
pti
ve
Cellular Network
GPRS, 3
/
4G
Su
pp
orts re
p
ort
p
ush-no
tifi
ca
ti
on to ARC & Cloud, te
x
t
no
tifi
ca
ti
on via S
M
S, and audio no
tifi
ca
ti
on via
p
hone call
Standard
802.11b
/
g
/
n
Encry
pti
on
Su
pp
orted
Channel
2.4G
A
pp
lica
ti
on
iV
M
S-4200, and mobile APP
Protocol
SIA - Contact ID
IC Card
12
U
ser
13 (1 Installer, 1 Administrator, and 11 General
U
ser)
Power
5 VDC
,
10W
Consum
pti
on (without HDD) <5.6W
O
p
era
ti
on Tem
p
erature
–10
℃
to 55
℃
O
p
era
ti
on Humidity
10% to 90%
Shell
M
aterial
PC+ABS
Dimension(W
x
H
x
D)
155
x
155
x
35mm
Wireless Device
Connec
ti
on
Applica
ti
on &
Protocol
User
RF
Others
Wi-Fi
Add Peripheral Device
While the control panel is not in the configuration mode, press the function button on the
side of the control panel once and trigger a peripheral device.
Check RF Signal
While the control panel is not in the configuration mode, double press the function button,
and you can check the RF signal strength on the peripheral device .
Set up via 4200 Client
Add a Camera for the Zone
Configure Video-Push
1. Download and install the iVMS-4200 client.
Note: Get the client software from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Settings, change the port as 80, and click Add to Client.
Note: You should activate the device for the first usage.
1. Click System-Network Camera, and you can add two cameras for the control panel.
2. Click Wireless Device-Zone, select a zone, click the Settings icon, and select a camera to link
with the zone.
You can also link a camera with the zone via APP, refer to the Wireless Security Control Panel
User Manual for details.
Function Button Operation
Input the device IP address in the address bar of the web browser. Create a password to
activate the device and log into the web client.
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connectiing the network cable with computer directly :192.0.0.64
Note: Keyfobs cannot be added by function button operation.
You can view the alarm video via APP and email.
For detailed settings, refer to Security
Control Panel User Manual.
4
For multi-language switch , refer to Security Control Panel User Manual (scan the QR code) for details.
Note: Add card or keyfob via the web client before adding peripheral device for clearing tampering alarm
.
This product and - if applicable - the supplied accessories too
are marked with "CE" and comply therefore with the
applicable harmonized European standards listed under the RE
Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD
Directive 2014/35/EU, the RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points. For
more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a
battery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentation
for specific battery information. The battery is marked with
this symbol, which may include lettering to indicate cadmium
(Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the battery to your supplier or to a designated collection
point. For more information see:www.recyclethis.info
CAUTION
RISK OF EXPLOSION IF BATTERY IS
REPLACED BY AN INCORRECT TYPE
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUCTIONS
Recommended Power Adaper
Manufactory: Shenzhen HONOR Electronic Co., Ltd
Model: ADS-12B-06 05010E
Input rating: 100-240V~50/60Hz Max. 0.3A
Output rating: 5V 2.0A
UD13152B-A