HIKVISION DS-PWA32-HR Скачать руководство пользователя страница 1

EN50131-2-2:2008

EN50131-1:2006+A1:2009

Environmental Class (EC) II

Security Grade (SG) 2

DS-PD2-P10P-W

Wireless 10m Pet Immune PIR Detector

DS-PWA32-HR

Wireless Security Control Panel

A

B

C

CEILINGBRACKET

<24kg

2m

1m

3m         4m          5m         6m         7m          8m        9m                    

9m

8m

7m

6m

5m

4m

3m

2m

1m

10m

10m

8m        9m                    

10m

2.4m 

2m

1m

3m         4m          5m         6m         7m         

HORIZONTAL COVERAGE

VERTICAL COVERAGE

85

56 ZONES

6 PLANES

°

Diagram References

The batteries supplied have been chosen to provide long service life 

whilst, for safety reasons, having limited output current.The battery is 

protected on purchase by a piece of plastic that must be removed for 

operation. When disposing of the product, the battery must be removed  

and disposed of separately in accordance with the local regulations.

Specification

Battery Information

Hangzhou Hikvision Digital Technology CO.,Ltd.           No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

This 

product

 and - 

if

 

applicable

 - the 

supplied

 accessories too are 

marked with "CE" and c

omply 

t

herefore w

ith th

e applicable h

armonized 

Eu

ropean s

tandards listed und

er the RE Directive 2014/53/EU, 

the RoHS Directive 2011/65/

E

U.

For electrical products sold within the European 

Community. At the end of the electrical products 

lif

e

, it should not be disposed of with household 

waste. Please recycle where facilities exist. Check 

with your local Authority or retailer for recycling 

advice in your country.

+

-

>5s

+

-

REGISTRATION

+

-

<24kg

>24kg

5s

+

-

LED ON

LED OFF

LOW

HIGH 

+

+

+

+

+

+

+

+

CR123A

LITHIUM

-

HIGH 

LOW

TAMPER

=

=

REGISTRATION

BRACKET TAMPER

SEE SECTION4

A

B

E

C

D

WALLBRACKET

Add Locally

1. Make the security control panel enter the registration mode.
2.Add the detector: Hold the registration key until the three LEDs flash 
alternately.The green LED will flash 8 times if the registration is finished.
3. Communication Test: Release the TAMPER spring to trigger the alarm.

Note:

 

The di

stance between the security control panel and the detector 

should be less than 50 cm.

Initialize the Detector

1.Remove the battery to power the detector off.
2. 5s later,hold the registration key and reinstall the battery to power the
detector on at the same time to make the three LEDs start flashing alternately.
Release the registration key while the three LEDs flash once together.

REAR TAMPER

BREAK-OUT

1

3

4

2

1

3

4

Diagnostics

(Check Signal Strength 

Before

 

Mounting)

Bracket Wiring

Wireless device control

Please register the detector within 90 seconds after it being powered on.

3

4

1

2

Registration

E N G L I S H

Diagram References

E N G L I S H

23

24

25

26

Tear off 

Cable Pipe

Cable Pipe

Cable Pipe

Cable Pipe

2

2

2

7

Detec

ti

on Range

10m

Detec

ti

on Angle

85°

Detec

ti

on Zones

56 zones and 6 

p

lanes

Detec

ti

on S

p

eed

0.3–3.0 m

/

s

M

oun

ti

ng Height

1.8-2.4m

Animal Immunity

24kg

Blue Wave Technology

Su

pp

orted

Digital Tem

p

erature

Com

p

ensa

ti

on

Su

pp

orted

Tam

p

er Protec

ti

on

Front, rear, and bracket tam

p

er

signal in

p

ut

Signal Strength Indicators (SSI) Su

pp

orted

Frequency

433/

868

M

Hz

M

odula

ti

on

2GFSK

Range in o

p

en s

p

ace

800m

3V lithium ba

tt

ery included

1

x

 CR123A

General ba

tt

ery li

f

e (years)

2

O

p

era

ti

ng | storage

-10°C  to +40°C (Cer

tifi

ed)

Weight

125g

Dimensions(H 

x

 W 

x

 D)

117 

x

 69 

x

 50mm

Ceiling 

M

ounted Bracket

Su

pp

orted

Wall 

M

ounted Bracket

Su

pp

orted

Lens characteris

ti

cs

Key features

Other details

Accessories

Electrical speci

ca

ti

ons

Wireless

Make sure the LED keeps green at the installation position when the detector is in 
the signal strength mode before mounting.

2

21

2

1

2

2

2

3

2

4

2

5

2

6

2

7

2

8

2

9

2

10

2

11

2

12

22

Appearance

Installation

Set up via APP

Log Into the Web Client

Set Up

1

2

3

Set up via Web Client

AC Power

Power On

System Fault
No Fault
Panel is added to 

Hik-connect account

Panel is not added to 

Hik-connect account

Armed

Disarmed

Alarm Occurred

Device Tampered

No Alarm

Power Off

Fault

Link

Arm

/Disarm

Alarm

Note: Remove the rear cover, and some of the components and interfaces are on the rear panel. 

2

1

2

2

2

3

2

5

2

4

1. Loosen the screw on the rear cover. Slide down the rear cover and remove it from the 

control panel.

2. Insert a SIM card into the SIM card slot.  

3. Connect the battery to the control panel.

4. Connect the power adapter to the control panel and a power outlet. The power indicator 

turns green about 30s later, which means that the device is powered on. 

Note: The condition of no SIM card, no battery, AC power off, or network disconnected, will cause Control Panel Fault.

5. Connect the Ethernet cable to an internet outlet. While the device is added to a Hik-Connect 

account, the link indicator turns green. 

6. Secure the rear cover in the installation position with the supplied screws. Attach the 

control panel on the rear cover, and tighten the rear cover screw to complete the installation.

        Side Opening

If you need to route the cable though the botton of the panel, remove the sheet of the side 

opening.

1. 

Log into the App Store or Google Play and input Hik-Connect to search and install the 

mobile client. 

2. Log into the APP with Hi-Connect account.

3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).

4. Tap Connect to a Network.  Select Wireless Connection (AP) as the connection mode.

5. Push the AP/STA mode switch to the AP position, tab Confirm.

6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi ,  and 

click Next.

7. Create a password to activate the device.

8. Push the AP/STA mode switch to the STA position.

Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before 

activation if you add the device by entering the device serial No.(SN).

SIM Card Slot

Battery  Connector

Network Interface

Power Interface

Reset Button

AP&STA Switch

Tamper Spring

2

12

2

11

2

10

2

9

2

8

2

7

2

6

Note: The function of GPRS or 3/4G(implemented with build-in SIM card slot) depends on the model of the device.

TAMPER Screw

It is compulsory to secure the TAMPER screw.

Specification

Alarm In

p

ut

32

Alarm Out

p

ut

32

Siren

2

Key

f

ob

8

Par

titi

on

1

Interac

ti

on

Audio Out

p

ut

1, 1.5W

RF Frequency

433

/

868

M

Hz

RF 

M

odula

ti

on

2GFSK

RF Distance

800m

O

p

en Area

Wired Network

Ethernet

10

M/

100

M

 Sel

f

-ada

pti

ve

Cellular Network

GPRS, 3

/

4G

Su

pp

orts re

p

ort 

p

ush-no

tifi

ca

ti

on to ARC & Cloud, te

x

no

tifi

ca

ti

on via S

M

S, and  audio no

tifi

ca

ti

on via 

p

hone call

Standard

802.11b

/

g

/

n

Encry

pti

on

Su

pp

orted

Channel

2.4G

A

pp

lica

ti

on

iV

M

S-4200,  and mobile APP

Protocol

SIA - Contact ID

IC Card

12

U

ser

13 (1 Installer, 1 Administrator, and 11 General 

U

ser)

Power

5 VDC

10W

Consum

pti

on (without HDD) <5.6W

O

p

era

ti

on Tem

p

erature

–10

 to 55

O

p

era

ti

on Humidity

10% to 90%

Shell 

M

aterial

PC+ABS

Dimension(W

x

H

x

D)

155 

x

155

x

35mm

Wireless Device 

Connec

ti

on

Applica

ti

on & 

Protocol

User

RF

Others

Wi-Fi

Add Peripheral Device 

While the control panel is not in the configuration mode, press the function button on the 

side of the control panel once and trigger a peripheral device.

Check RF Signal 

While the control panel is not in the configuration mode, double press the function button, 

and you can check the RF signal strength on the peripheral device .

Set up via 4200 Client

Add a Camera for the Zone

Configure Video-Push

1. Download and install the iVMS-4200 client.

Note: Get the client software from the official website:www.hikvision.com.

2. Enter Device Management page, select the device in the Online Device List, click Edit 

Network Settings,  change the port as 80, and click Add to Client.

Note: You should activate the device for the first usage. 

1. Click System-Network Camera, and you can add two cameras for the control panel.

2. Click Wireless Device-Zone, select a zone, click the Settings icon, and select a camera to link 

with the zone.

You can also link a camera with the zone via APP, refer to the Wireless Security Control Panel 

User Manual for details.

Function Button Operation

Input the device IP address in the address bar of the web browser.  Create a password to 

activate the device and log into the web client. 

Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device  must be in the AP mode. 

Default IP Address when connectiing the network cable with computer directly :192.0.0.64

Note: Keyfobs cannot be added by function button operation.

You can view the alarm video via APP and email. 

For detailed settings, refer to Security 

Control Panel User Manual.

4

       For multi-language switch , refer to Security Control Panel User Manual (scan the QR code) for details.

Note: Add card or keyfob via the web client before adding peripheral device for clearing tampering alarm

.

This product and - if applicable - the supplied accessories too 

are marked with "CE" and comply therefore with the 

applicable harmonized European standards listed under the RE 

Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD 

Directive 2014/35/EU,  the RoHS Directive 2011/65/EU

2012/19/EU (WEEE directive): Products marked with this 

symbol cannot be disposed of as unsorted municipal waste in 

the European Union. For proper recycling, return this product 

to your local supplier upon the purchase of equivalent new 

equipment, or dispose of it at designated collection points. For 

more information see: www.recyclethis.info

2006/66/EC (battery directive): This product contains a 

battery that cannot be disposed of as unsorted municipal 

waste in the European Union. See the product documentation 

for specific battery information. The battery is marked with 

this symbol, which may include lettering to indicate cadmium 

(Cd), lead (Pb), or mercury (Hg). For proper recycling, return 

the battery to your supplier or to a designated collection 

point. For more information see:www.recyclethis.info

CAUTION

RISK OF EXPLOSION IF BATTERY IS 

REPLACED BY AN INCORRECT TYPE

DISPOSE OF USED BATTERIES 

ACCORDING TO THE INSTRUCTIONS

Recommended Power Adaper 

Manufactory: Shenzhen HONOR Electronic Co., Ltd

Model: ADS-12B-06 05010E

Input rating: 100-240V~50/60Hz Max. 0.3A

Output rating: 5V  2.0A  

UD13152B-A

Отзывы: