background image

DS-PK1-LT-WE/WB Series
Wireless LCD Keypad

Diagram References

E N G L I S H

©2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without
notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions.

Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION
BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR
LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL
NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN
THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Appearance

2

Indication

1

+ identifies the positive terminal(s) of equipment which is used with, or generates direct current. - identifies the negative terminal(s) of equipment which is used with, or generates direct current.
No naked flame sources, such as lighted candles, should be placed on the equipment.
The serial port of the equipment is used for debugging only.
Install the equipment according to the instructions in this manual.
To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions.
Keep right direction when using the equipment.
The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation.
After the installation, the equipment, including any associated mounting plate, shall not be damaged.

Fault

Fire Alarm

Panic Alarm

Medical Alarm

Stay Arm

Away Arm
Settings

Output

Disarm

Back

Scroll Up/Delete

Scroll Down

Confirm
Swipe Tag

Query

Lock

Armed/Disarmed

Enrollment/Signal Strength

With Fault

Enrollment

LED Description

Armed

Disarmed

Solid orange

Solid blue

Solid green

Alarm

Find Me Mode

Note: Event Alarm Priority > Tampering Alarm Priority

Tampering Alarm: Solid red
Event Alarm: Flashing red
No Alarm: Off

Flashing red

Off

No Fault

Signal Strength

Power On

Back Light

Alarm

Flashing green: Strong
Flashing orange: Medium
Flashing red: Weak/Disconnect

Flashing orange: Enrolling
Green flashes 7 times: Enrolled

Solid green for 1 s

-The back light is on by default, you can set the On/Off schedule on
the web client/APP of the control panel. Refer to the user manual of
control panel.
-It turns off when there is no key operation for more than 10 s to 30 s
(adjustable).
-If the keypad is not enrolled to the control panel, the back light is

off.

1

Tamper Switch

Power Switch

Touch Key Serial Port

MCU Serial Port

RFM Serial Port

Flashing green

Flashing blue

Entry Delay

Exit Delay

UD27093B

Содержание DS-PK1-LT-WE Series

Страница 1: ...HIRD PARTIES INCLUDING WITHOUT LIMITATION RIGHTS OF PUBLICITY INTELLECTUAL PROPERTY RIGHTS OR DATA PROTECTION AND OTHER PRIVACY RIGHTS YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END USES INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAF...

Страница 2: ...R code or enter the serial No on the peripheral 2 Push the power switch of the peripheral to ON and it will be automatically enrolled to the control panel 1 Remove the screw on the bottom of the keypad 2 Disassemble the keypad and remove the rear panel 3 Power on the security control panel 4 Download and install APP 4 Log in APP and tap the icon Scan the QR code or enter the control panel serial N...

Страница 3: ... fault 1 Password Tag 2 Use to confirm Lock Unlock keypad Relay output Settings One push Arm Backspace Delete all Fire alarm Hold 3 s Hold 3 s Hold 3 s Hold 3 s to lock the keypad for 60 s Hold 3 s again or wait 60 s to unlock Panic alarm Medical alarm Arming Process Enabled Disabled on Control Panel Pre arming Indication The keypad displays Waiting for arming The fault LED turns solid orange Faul...

Страница 4: ... this permission Bypass Restore Bypass Bypass Restore bypass zones WE Series WB Series Wireless technology RF frequency 868 MHz 433 MHz RF modulation RF distance 1200 m open area 800 m open area LED indicatior Buzzer Power switch Tamper proof Serial port Tag reader built in Numeric key System fault display System status display Operation Configuration Power consumption Battery type Battery life sp...

Отзывы: