Страница 2: ...operations or typographical errors We will update the contents of this manual according to the enhancement or change of product function and will regularly improve and update the hardware and software products described in this manual The updated content will be added to the new version of this manual without notice The contents in this manual only provide reference and guidance for users please r...

Страница 3: ...formation of the text for emphasis and addition Warnings The installation and use of this product must strictly comply with electrical safety regulations of the nation and territory of use Use a power adapter supplied by a regular manufacturer Disconnect the power supply during wiring disassembly and assembly and other operations If the equipment does not work properly please contact the dealer wh...

Страница 4: ... is shocked or subject to shock The equipment may be damaged if ignoring this item Provide a good ventilation environment Do not operate in humid environment Do not operate in explosive environment Keep the product surface clean and dry Avoid contact with exposed circuits Do not touch exposed contacts and components when the product is powered up 3 DS PF E0204 Series Energizer User Manual ...

Страница 5: ...ergizer 10 Chapter 3 Use and Installation 11 3 1 Equipment packaging and visual inspection 11 3 2 Installation methods 11 3 3 Energizer wiring diagram 13 3 4 Installation instructions for external equipment 14 3 4 1 Installation of siren 14 3 4 2 Host Topology 14 Chapter 4 Operating Instructions of the Energizer 15 Chapter 5 Front end Fence Installation 16 Appendix Packing List 30 Appendix Restric...

Страница 6: ...d other perimeter security systems the product has the advantages of low false alarm rate no restriction of terrain and environment high security etc It has been widely used in substation China Mobile Telecom and Unicom base stations factory Residential areas schools villas warehouses airports military bases detention centers prisons and other places Electric Fence is mainly composed of energizer ...

Страница 7: ...h internal wiring enables high voltage and pulse connection more reliable stable and safe Alarm output mode of the Output pulse voltage technology is programmable with the design concept of multi combination of industrial control protocol communications and system integration networking Multi function relay controls the programmable output relay so that the Electric Fence can be perfectly compatib...

Страница 8: ... high voltage pulse but also the core of the system to output high voltage pulse for the front end fence and detect fence alarm status In the cycle of slightly greater than 1s the system usually generates 5000V 10000V pulsed high voltage with the duration of only about 0 0001s on the fence line when invaders touch the adjacent two conductive lines the pulsed high voltage can generally penetrate th...

Страница 9: ...ructure 1 4 1 Description of the equipment panel 8 Run status display Energizer runtime display Zone voltage and current display Zone alarm display Setup Down Up Power button DS PF E0204 Series Energizer User Manual ...

Страница 10: ...to purchase other auxiliary power supply to achieve cost savings Zone interface used to connect sound and light alarm indoor tweeters and other equipment KEY COM GATE The interface is used for connecting infrared and other auxiliary equipment without adding modules which is easy to operate and save costs See Chapter 3 4 for wiring diagrams Battery connector used to connect the battery High voltage...

Страница 11: ...commended line 4 lines 8 lines Indication LCD screen Pulse period 1S Duration 0 1S Flame retardant factor UL94V 0 The current peak 10A The maximum energy 5J Power consumption 24W Weight 3 9kg Operating Humidity 10 90 Power supply AC90 260V Size 380 255 110mm 10 DS PF E0204 Series Energizer User Manual ...

Страница 12: ...uld match the serial number with no damage and stains If you have any questions above please contact your local dealer immediately After opening the box make an inventory of the equipment and whether the model and the number of accessories are correct according to the packing list Check whether all items are in good condition if having any abnormal circumstances please contact the company or local...

Страница 13: ... energizer observe the fixed hole and then hang it on the fixed screw of the energizer s fixed plate as shown in the Figure 3 Installation complete 12 HIKVISION HIKVISION DS PF E0204 Series Energizer User Manual ...

Страница 14: ...re marked with F1 F2 R1 R2 etc which should respectively access to corresponding high conductivity wire of the front end fence as shown in the Figure Bridge high conductivity wire with high voltage insulated conductor at the end of the front end fence then wiring is completed as shown in the Figure Ground Ground Ground 13 R1 R2 R3 R4 F1 F2 F3 F4 4 3 2 1 4 3 2 1 HIKVISION R2 F1 F2 R1 R4 F3 F4 R3 3 ...

Страница 15: ... zone 14 3 4 2Host Topology R1 R2 R3 R4 Ground Ground F1 F2 F3 F4 Ground 4 3 2 1 4 3 2 1 R2 F1 F2 R1 R4 F3 F4 R3 HIKVISION R1 R2 R3 R4 Ground Ground F1 F2 F3 F4 Ground 4 3 2 1 4 3 2 1 R2 F1 F2 R1 R4 F3 F4 R3 HIKVISION R1 R2 R3 R4 Ground Ground F1 F2 F3 F4 Ground 4 3 2 1 4 3 2 1 R2 F1 F2 R1 R4 F3 F4 R3 R1 R2 R3 R4 Ground Ground F1 F2 F3 F4 Ground 4 3 2 1 4 3 2 1 R2 F1 F2 R1 R4 F3 F4 R3 HIKVISION HI...

Страница 16: ... and other information of each zone indicating that the energizer begins to work and runs properly When the defense state is revoked the energizer will not make any sound and the scroll bar above the screen doesn t have any changes 3 Press the setup button and up and down keys on the LCD panel to adjust the voltage of each zone 4 When there is an alarm the energizer will identify the alarm categor...

Страница 17: ...r plants around to avoid the inconvenience during and after the installation And then the installation work could be arranged in accordance with the specific circumstances of the site This installation manual may involve technical inaccuracies unrelated functions or operations of the product or printing errors So our company will update the contents of the manual according to the improvement or ch...

Страница 18: ...crews Joint Clamp Siren Customer self provided Lightning Deliverter Warning Sign Expansion screw Customer self provided Waterproof Box Front fence composition General Post General Post Insulator 17 DS PF E0204 Series Energizer User Manual Earthing Pile General Post Insulator General Post Cap Post Accessories for Security Post Post Accessories for Knighthead Screw Screw ...

Страница 19: ...rimeter to bury two φ2 0 cm PVC pipes galvanized pipe is preferred for signal wire and power wire 2 Spare outlet wire when the pipe arrives at the energizer 3 Signal wire and power wire go through the buried PVC pipes separately by the use of punch to the energizer and then set aside a distance the length from the entrance of the pipe to the energizer to connect the energizer with the terminal bac...

Страница 20: ...Diagram of GCS 19 DS PF E0204 Series Energizer User Manual ...

Страница 21: ...joint clamps Siren waterproof box earthing pile Installation principles It is recommended to install an security post every 50 m a knighthead every 5m but it depends on distance of wall blocks at the site A row of tensioner be installed between every two security posts A joint clamp should be mounted at the ends and joint areas of high conductivity wire A warning sign should be set up every 10 m A...

Страница 22: ...neral Post Base Frame for Security Post 2 General Post Insulator 4 Screw 4 Expansion screw Customer self provided General Post Cap 1 For screws 2 Fix the general post insulator on the general post with a screw Fixed general post and for screws User Man ual aS M edInstallation steps security post exemplified by four wire security post Note Security post are installed at the ends and the places wher...

Страница 23: ... Cap 2 Installation of general post cap and general post insulator 4 Fix the assembled knighthead on the wall with expansion screw 5 Installation completion 3 Install the general post base frame for Knighthead screw to the bottom of the knighthead General Post Expansion screws Fix the general post insulator on the general post with a screw For screws 2 Fixed general post and for screws Knighthead ...

Страница 24: ...int clamp 3 After general post insulators are well connected high conductivity wire go through tensioner hanging knighthead along the perimeter 4 The installation of back end of the end post is the same with that in front Attention to beauty while wounding and pull the front high conductivity wire in order 5 To avoid waste two high conductivity wire can be bonded together to be one when they are n...

Страница 25: ...r Put high conductivity wire into three holes in order to form a straight line It is beautiful to maintain a vertical line or a slash between the upper and lower of strainers Lightning deliverter Fixed on the mounting bracket with its nuts firstly lightning deliverter each zone installs one Grounding principles the ground point is generally at the end of the electric fence but the ground point of ...

Страница 26: ...ding Fix with No 10 concrete anchor Siren Siren is firstly fixed on the bracket with its nuts Siren is generally installed above the waterproof box and each zone should have one that is fixed on the wall with concrete anchors Each light has two power lines leading to the waterproof box by a two core wire to connect with energizer Fix it on the base with screws Fix it on the wall by NO 8 concrete a...

Страница 27: ...nd waterproof box that can be fixes on the wall with concrete anchors as is shown in fig Fix waterproof box with expansion screws at the back 2 Make sure the energizer waterproof box and earthing pile are well connected The grounding of energizer weak voltage grounding connect with the shielding layer of communication wire and high voltage fences should be apart from each other to avoid interferen...

Страница 28: ...y applied in a corner area in the perimeter or on supportive security posts to connect high conductivity wires on both sides It should be connected with insulated cable or high conductivity wires as is shown in fig 3 End across the line it is used in the end of the perimeter to form an effective loop which is connected with high conductivity wire as is shown is fig high conductivity wire high cond...

Страница 29: ...ly or destroy of the host Elimination Check whether the power supply is normal or not If it is normal the host may be destroyed by high voltage power supply or lightning please contact with our company Failure Alarm of the host but other alarm equipment not Identification failure of other alarm equipment or abnormal alarm of the host Elimination test whether the terminals of alarm on off of the ho...

Страница 30: ...nd keep a good insulation Low power supply of the host it is required that the power supply should not be lower than 90V If the methods above fail to solve the problem please contact with our company Failure the host still alarms after an exclusion of four failures above Identification wrong installation of the front end fences by installation personnel resulting in the host is not working properl...

Страница 31: ...astic parts o o o o o o Glass o o o o o o Dashboard o o o o o Power supply o o o o o Accessories o o o o o Explanation Exemption list material does not apply to this table 1 Ο indicates that the content of the restricted substance in all homogeneous materials of the component is below the limit requirement specified in the RoHS 2 0 standard 2 X indicates that the content of the restricted substanc...

Страница 32: ...e warranty Failure to produce valid warranty certificate and valid purchase invoice or receipt Improper use environment or conditions such as incompatible power supply ambient temperature humidity lightning strike and so on lead to product failure P roduct failures are caused by accidents negligence disasters improper or incorrect operation network attacks etc Failure or damage caused by installat...

Страница 33: ...nufacture _______________ Date of purchase __________________ If you have other requirements please fill in the following ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Distributor ________________ Telephone _________________ Address _________________________________...

Страница 34: ......

Отзывы: