background image

Panic Alarm Station

 User Manual

 

57 

 

Calling Settings 

Steps 

1. Click Two-way Audio Settings → Calling Settings

2. Configure parameters. 

Call Timeout 

Refers to the playing time of the call prompt tone. The range is 40 to 60 seconds. 

Call Extension Time 

When you press the call wait during calling the panic alarm center station, the extension time 
of the prompt tone based on the maximum ringing time is call extension time. The range is 10 
to 60 seconds. 

3. Click Save

Voice Prompt 

Steps 

1. Click Two-way Audio Settings → Voice Prompt

2. Configure Call Waiting ToneReject ToneTwo-way Audio End ToneEmergency Help Tone

3. Enable Mute Schedule

4. Click Mute, move the mouse over the time bar, and long press and drag the left mouse button to 
draw the time period. 

 

Figure 4-4 Mute Schedule Settings 

5. Edit the time period. 

Edit Time Period Length and Start/End Time 

Содержание DS-PEA102R

Страница 1: ...Panic Alarm Station User Manual...

Страница 2: ...N OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY OR OTHERWISE IN CONNECTION WITH THE USE OF THE PRODUCT...

Страница 3: ...outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Conditions This device complies with part 15 of the FCC...

Страница 4: ...Manual iii the battery to your supplier or to a designated collection point For more information see www recyclethis info Industry Canada ICES 003 Compliance This device meets the CAN ICES 3 A NMB 3...

Страница 5: ...ating or fire hazards caused by overload Make sure the plug is properly connected to the power socket If smoke odor or noise arises from the device immediately turn off the power unplug the power cabl...

Страница 6: ...nt The average lifespan varies so periodic checking is recommended Contact your dealer for details Improper use or replacement of the battery may result in explosion hazard Replace with the same or eq...

Страница 7: ...1 3 2 3 Set NAT 21 3 2 4 Set SIP 23 3 2 5 Set Hik Connect 23 3 2 6 Access the Platform 24 3 2 7 Set Alarm Center 25 Alarm Settings 27 3 3 1 Set Zone 27 3 3 2 Set Relay 29 3 3 3 Set Call Waiting 30 3 3...

Страница 8: ...ck Zone Status 47 3 7 2 Check Relay Status 47 Other Settings 47 3 8 1 Set Auxiliary Output 47 Chapter 4 Web Client Settings 48 Live View 48 Configuration 48 4 2 1 System 48 4 2 2 Network 49 4 2 3 Vide...

Страница 9: ...in school hospital metro scenic area prison etc Key Features Network adaptive and video and audio adaptive Built in omnidirectional microphone Supports two way audio communication and configuration S...

Страница 10: ...how to activate a device and modify its IP address For batch activation and IP addresses modification refer to User Manual of SADP for details Steps 1 Run the SADP software and search the online devic...

Страница 11: ...ce status from the online device list and select an inactive device 5 Click Activate 6 Create and confirm the admin password of the device STRONG PASSWORD RECOMMENDED We highly recommend you create a...

Страница 12: ...he device You need to add the device to the client software before configure it See Add Device via Client Software Get the client software from the technical support and install the software according...

Страница 13: ...or the client software The SADP software is taken as an example for explanation Steps 1 Run the SADP software check the activated device and edit the IP Address Subnet Mask Gateway and other parameter...

Страница 14: ...set the network address IPv4 Address Subnet Mask IPv4 Gateway Address IPv4 4 Set the MTU Byte Device Port HTTP port and RTSP port for the device MTU Byte Maximum transmission unit which refers to the...

Страница 15: ...CP is enabled the DNS cannot be set Enable the UPnP function and you don t need to configure the port mapping for each port and the device is connected to the Wide Area Network via the router Steps Un...

Страница 16: ...rily edit the default port number If there is a port conflict and you need to edit the port number please modify the port number as follows HTTP Port By default the value of the HTTP port No is 80 Ser...

Страница 17: ...IP Settings Page Private Protocol SIP Protocol 2 Check Enable box to enbale the Sip server 3 Enter the Sip server parameters The server port No ranges from 1024 to 65535 The device ID ranges from 0 to...

Страница 18: ...r address Note The default server address is litedev hik connect com 4 Select Network Mode 5 Enter a verification code and click Generate QR code There will be a QR code displaying on the page 6 Click...

Страница 19: ...he port number of the platform Panel ID Panel ID is the unique identification of the device Communication Network Select the network mode for communication with platform Registration Status Display th...

Страница 20: ...ter and the default is Net Center 1 Server Mode The address type of the upload center server You can set Server Type as IP4 IP6 or Domain Name IP Address Server Domain Name Enter the server IP address...

Страница 21: ...ne has a default zone type default audio file and the default zone will automatically upload an alarm recovery report These three parameters Zone Type Audio File and Upload Alarm Recovery Report do no...

Страница 22: ...riggered an alarm is generated immediately without delay Fire Zone The fire zone must be set to a 24 hour alarm zone When the fire zone is triggered start the external siren sounder 24 hour Non voiced...

Страница 23: ...triggered the selected alarm output is on Channel After the zone is triggered the selected video channel is linked 6 Optional Click Copy to copy the zone parameter configuration to other zones 7 Click...

Страница 24: ...duration and waiting time Steps 1 Click to enter the Remote Configuration page go to Output Settings Waiting Call Waiting Settings Page 2 Set the call waiting parameters Calling Duration The playback...

Страница 25: ...eriod Modify the time period Click and select the added time period drag to modify the time period position click and select the added time period then moves the cursor to both ends of the time period...

Страница 26: ...Management Relay Relay Check the relays that need to be turned on off Click Enable Locked to change the relay switch status Click Refresh you can refresh the relay switch status Configure the audio i...

Страница 27: ...nd volume spkOut is the device s own audio input output 3 Click Save Upload the custom audio files to SD card and delete the audio file in the SD card Before You Start Insert the SD card into the devi...

Страница 28: ...t the beginning and end The length of the file name should be not more than 31 and the file name cannot contain symbols Each audio file size up to 2MB and up to 16 audio files are uploaded An audio fi...

Страница 29: ...age capacity to configure the video and audio parameters Stream Type The stream type of camera can be set as Main Stream or Sub Stream By default it is Main Stream The main stream is used for HD stora...

Страница 30: ...is the Main Stream the audio encoding type can be set as G711_U AAC or PCM And the audio encoding type of the sub stream is the same as the audio encoding type set in the main stream Video Encoding T...

Страница 31: ...l be updated Editing the display format Date Format Select the display format of the date in the Date Format Drop Down box Time Format Select Time Format as 24 hour or 12 hour OSD Format There are fou...

Страница 32: ...area of the check box in the Text Overlay List and enter display content in the text box Check the text and click Save to display the custom information You can drag the content to modify the location...

Страница 33: ...rop down box And click Save to save the settings System Settings Click to enter the Remote Configuration page go to Device Information Time Time You can set the time zone NTP DST on the Time page You...

Страница 34: ...configuration for remote debugging Click to enter the Remote Configuration page go to System Security Secuirty Check Enable SSH to enable SSH service and click Save By default the SSH service is not...

Страница 35: ...assword attempts and lock duration Max Password Attempts The maximum times that the user attempts to enter the password By default it is 7 the available value is 3 to 10 Lock Time The lock duration of...

Страница 36: ...nd confirm it 3 Click Save User Search and view the alarm logs exception logs operation logs and event logs Click to enter the Remote Configuration page go to System Log Query You can set the search c...

Страница 37: ...Panic Alarm Station User Manual 43 Log Query You can click Backup and download the search result Click to enter the Remote Configuration page go to System Security Audit Log Security Audit Log...

Страница 38: ...tore default settings restore all settings and import export configuration file Reboot Restart the device Restore Default Settings Restore the default settings that is except the IP address and user i...

Страница 39: ...ord for the exported file The password is used for importing verification Remote Upgrade Upgrade the device remotely via the client software Click and select the upgrading file And click Upgrade to up...

Страница 40: ...the week The device performs a check at the set time on this day of the week Manual check Click Verity to start the check and the check results are displayed in the list Table 3 1 Description of Chec...

Страница 41: ...us Relay you can view the relay status Other Settings Enable the auxiliary power output to use the 12 V auxiliary power Steps 1 Click to enter the Remote Configuration page go to Other Auxiliary Power...

Страница 42: ...ion Click System System Settings Basic Information You can change device name in this page And you can see device No Model Serial NO version etc System Settings Time Settings Click System System Setti...

Страница 43: ...en there is a port conflict and you need to change the port number please change the following information accordingly HTTP S HTTP The default HTTP port is 80 To change the port you need to add the ch...

Страница 44: ...can communicate with each other Click Network Device Access SIP Private Protocol Steps 1 Enable SIP Enrollment Status Display the device enrollment status If the device has been enrolled to the SIP se...

Страница 45: ...he verification code 3 Set Server Address You can select default or custom When Custom is checked you need to set the server address manually You can contact the technical support to get the address 4...

Страница 46: ...r The HIK protocol is 7200 by default The NAL2300 protocol should be set as 4001 Protocol The default protocol is HIK Protocol User Name It supports numbers and letters The HIK protocol can set the le...

Страница 47: ...he I frame interval is the smaller the code stream fluctuation is but the image quality is relatively poor On the contrary the larger the code stream fluctuation is the higher the image quality is It...

Страница 48: ...nformation After saving the displayed information will be updated to a new position Change Display Format Date Format You can select the date display format in the date format drop down box Time Forma...

Страница 49: ...Content Select whether to display the name date or week according to your need After selecting the corresponding information will be displayed on the image Channel Name You can change the channel nam...

Страница 50: ...t there is no alarm sound Disabled No event will trigger an alarm Audio File Select the zone audio file Mute can be selected Upload Restored Alarm After enabling when the alarm is recovered the report...

Страница 51: ...extension time of the prompt tone based on the maximum ringing time is call extension time The range is 10 to 60 seconds 3 Click Save Voice Prompt Steps 1 Click Two way Audio Settings Voice Prompt 2...

Страница 52: ...select the file address in the pop up window and import Note Audio file is wav or mp3 format the file name can be composed of English characters numbers and Chinese characters and does not contain sp...

Страница 53: ...ort configuration file which includes device parameters Restore to Default Settings Click Restore device parameters except for IP address will restore to default settings Restore to Factory Settings C...

Страница 54: ...is unable to detect audio output status IP Address Filter Steps 1 Click Maintenance and Security Security IP Address Filter 2 Enable filter click Add to add IP address to the list 3 Click to change I...

Страница 55: ...to 10 Locking Duration The default setting is 600 seconds and the setting range is 10 to 3600 3 Click Save Note If you enter the wrong password more than the set number of times the IP address of the...

Страница 56: ...Panic Alarm Station User Manual 62 Chapter 5 Communication Matrix and Device Command Scan the QR code to get the communication matrix and device command...

Страница 57: ...Panic Alarm Station User Manual 63 UD24372B...

Отзывы: