Panic Alarm Station
User Manual
42
4.
Select the linked siren, alarm lamp, linked trigger and others.
5.
Click
Copy to
to copy all these settings to other zones.
6.
Click
Save
to save the settings.
Four zone types in the Zone Parameters: Instant Zone, Fire Alarm Arming Zone, 24 Hour Non-voiced Zone and Shield
Zone.
Instant Zone
Alarm is sent out without any delay once the detector is triggered.
Fire Alarm Arming Zone
When the 24-hour armed zone is triggered by fire alarm, sirens will send out
resonant and special sound.
24 Hour Non-voiced Zone
When the 24-hour armed zone is triggered, it will send alarm reports to the
surveillance center without any audible warning. The 24 hour silence alarm
zone is not affected by manual or scheduled arming/disarming.
Shield Zone
The alarm will not be triggered.
Panic alarm station has three zones among which two are ordinary zones and one is emergency zone.
Zone Event Settings
4.3.2
Steps:
1.
Click
Control Panel > Event Management > Zone Event
to enter the Zone Event configuration interface.
2.
Select the corresponding zone on the left and then tick necessary items.
3.
(Optional) Click
Copy to
to tick the necessary items.