HIKVISION DS-PDPG8P-EG2-WE Скачать руководство пользователя страница 5

4

Test

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Detector zones and planes

The zones and plans of the detector are shown below.

PIR Test

The detector will enter the PIR walk test mode (3 minutes) after being enrolled.

Trigger the detector within the detection range.

If the blue LED flashes 2 s, the installation position for PIR detection is properly. If the LED indicator is still off, 

adjust the position of the detector. 

BG (Break Glass) Test

Use a tester to simulate the sound of glass-break at the required place.

If the blue LED flashes 2 s, the installation position for BG detection is properly. If the LED indicator is still off, 

adjust the position of the detector. 

5

85.9°

(a) Detection Range

52 zones
4 planes

10m

12m

1m 2m

4m

6m

8m

10m

12m

1m

2.4m

2m

4m

6m

8m

10m

12m

1m

2m

4m

6m

8m

2 s

2 s

TESTER

TEST

Содержание DS-PDPG8P-EG2-WE

Страница 1: ...button on the control panel page to make the control panel enter the enrollment status 2 Loosen the screw and remove rear panel 3 Power on the peripheral and it will be automatically enrolled to the control panel This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014 3...

Страница 2: ...tamper button and make the device power off and then power on for re enrollment 3 Installation 2 Enroll the Peripheral with QR and serial No 1 In the APP tap the icon and scan the QR code or serial No on the peripheral 2 Loosen the screw and remove rear panel 3 Power on the peripheral and it will be automatically enrolled to the control panel Hangzhou Hikvision Digital Technology CO Ltd No 555 Qian...

Страница 3: ...e shall not be damaged with Screws a Knock out the screw holes on the rear panel 3 Adjust the pick up direction a knock out the sheet on the pick up hole at the required side b Toggle the joystick to adjust the pick up direction Note Please mount the detector with supplied screws or those in the same specification as the supplied one Hangzhou Hikvision Digital Technology CO Ltd No 555 Qianmo Road B...

Страница 4: ...sponge tape Bracket Installation Ceiling Bracket Fitting Non EN compliant Wall Bracket Fitting Hangzhou Hikvision Digital Technology CO Ltd No 555 Qianmo Road Binjiang District Hangzhou 310052 China 4 Note Installing with the Sponge Tape is non EN compliant ...

Страница 5: ...the blue LED flashes 2 s the installation position for PIR detection is properly If the LED indicator is still off adjust the position of the detector BG Break Glass Test Use a tester to simulate the sound of glass break at the required place If the blue LED flashes 2 s the installation position for BG detection is properly If the LED indicator is still off adjust the position of the detector 5 85 9...

Страница 6: ... or equivalent type only Dispose of used batteries according to the instructions provided by the battery manufactur er Do not expose the device to the corrosive gas Otherwise the equipment damage may occur Do not expose the device to the explosive situation Hangzhou Hikvision Digital Technology CO Ltd No 555 Qianmo Road Binjiang District Hangzhou 310052 China 5 Formatting Hold the tamper switch fo...

Отзывы: