Video Intercom Module Door Station
·
User Manual
2.
Set the sub module address according to the DIP rules, and install the rubber cover
back.
Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7, 8 are reserved.
Valid sub module address range is 1 to 8. The No. should be unique for sub modules
that connected to the same main unit.
The sub module address and corresponding switch status as below.
Sub Module
Address
1
2
3
4
.5
6
7
8
Digit 1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Digit 2
OFF
ON
ON
OFF OFF
ON
ON
OFF
Digit 3
OFF OFF OFF
ON
ON
ON
ON
OFF
Digit 4
OFF OFF OFF OFF OFF OFF OFF
ON
4.2
One-Module Installation
4.2.1
Installation Accessory Description
Figure 4-2
Front and Side View