Chapter 4 Device Settings
After installation and wiring completed, the turnstile will learn the open and closed position
automatically.
After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode,
passing mode and memory mode, pair the keyfob, initialize the hardware, switching between
RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC
diagram by setting the DIP switch on the main control board.
• Normal Mode: The device will work properly.
• Test Mode: Test mode is the same as the normal mode except that the device cannot report the
alarm, the event, or the people counting information to the center.
• Passing Mode: There are 9 passing modes, including controlled bi-direction, controlled entrance
and prohibited exit, controlled entrance and free exit, free bi-direction, free entrance and
controlled exit, free entrance and prohibited exit, prohibited bi-direction, prohibited entrance
and free exit.
• Memory Mode: By default, the memory mode is enabled. When multiple cards are presented
and authenticated, it allows multiple persons passing through the lane. When it counts the
passing people number is equal to the card presented times, or no person passing through the
lane after the last person passing, the barriers will be closed.
Note
You can also set the DIP switch on the main control board to control the entrance and exit
controlling type, keyfob pairing, etc. For details about the DIP switch value, see DIP Switch .
4.1 Pair Keyfob (Optional)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
1. Power off the turnstile.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board according to the figure
below.
3. Power on the turnstile and it will enter the keyfob pairing mode.
4. Hold the Close button for more than 10 seconds.