background image

Tri-pod Turnstile • User Manual 

 

 

Chapter 1 Product introduction

 

1.1 Brief introduction 

The electronic tripod turnstile, which is an electric control mechanism installed in the building 

structure,  is  used  to  form  an  access  control  system.  The  rotation  unit  consists  of  three  tubular 

arms which are positioned at 120

  intervals so that when the unit is at rest ,one arm will always 

be in the horizontal position(Barrier position).The  movement of the rotation unit can be realized 

by  pushing  arms  lightly. If  arm  rotates  more than  a  settled position,  the  elastic  potential  energy 

will drive the rotation unit to complete the whole process of rotation 

The electronic tripod turnstile, which has integrated the electronic and mechanical rotation, 

is a kind of advanced access controller. After being integrated with RFIC, IC and magnetic card, it 

can  meet  various  requirements  of  customers  and  therefore  can  be  widely  used  in  such  sites  as 

conference room, park and railway station, etc 

1.2 Function Features 

 

Standard  signal  input  port,  can  be  connected  with  most  of  the  access  control  board, 

fingerprint device and scanner other equipment; 

 

The  turnstile  has  automatic  reset  function,  if  people  swipe  the  authorized  card,  but  don’t 

pass through within the settled time, it need to swipe card again for entry; 

 

Card-reading Recording function can be set 

 

Automatic opening after emergency fire signal input 

 

Anti following : prevent illegal passing   

 

High light LED indicator , displaying passing status.   

 

Normal open can be also controlled via external button or manual key unlock   

 

Arm will automatically fall down when power failure 

Содержание DS-K3G4402 Series

Страница 1: ...AA Tripod Turnstile Quick Start Guide...

Страница 2: ...AND ERRORS HIKVISION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY SATISFACTORY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE THE USE OF THE PRODUCT BY YOU IS AT Y...

Страница 3: ...tion method for fingerprint device only fingerprint template will be saved which is impossible to reconstruct a fingerprint image As data controller you are advised to collect store process and transf...

Страница 4: ...must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE...

Страница 5: ...wer Source with 100 to 240 VAC or 12 VDC according to the IEC60950 1 standard Please refer to technical specifications for detailed information Do not connect several devices to one power adapter as a...

Страница 6: ...ct structure 7 1 4 2 Work principle 10 Chapter 2 Equipment Installations 10 2 1 Installation notes 10 2 2 Equipment Installation 10 2 3 Connection 12 2 4 Debugging instruction 12 2 5 Notice of use 13...

Страница 7: ...lectronic and mechanical rotation is a kind of advanced access controller After being integrated with RFIC IC and magnetic card it can meet various requirements of customers and therefore can be widel...

Страница 8: ...Operational voltage DC 24V 5 Voltage of indicator lamp DC12V 5 standard Working environment Indoor Working temperature 30 60 Humidity 5 90 Waterproof IP31 Installation interfaces for card readers 2 C...

Страница 9: ...ing cam The positioning cam is machined a guide way with a special profile In this guide way three points at a minimum distance from the centre are arranged at 120 intervals and correspond to the thre...

Страница 10: ...enoid tamper power supply NO Name Function 1 Access control device IC ID card access control fingerprint face recognition code reader access control device send delay signal to the turnstile board doo...

Страница 11: ...lease cut off the power The product must be earthed and an earth leakage breaker is necessary on the power supply The depth of buried PVC tube should be greater than 60mm and the exposed height above...

Страница 12: ...ng plate on the bottom of each turnstile 5 Drill hole by impact drill fix Expansion screws 6 Fix arm Before delivery we will dismantle two arm bar which can reduce some package cost and volume so befo...

Страница 13: ...lation we have completed connection of the circuit drive in the plate and provide 220 V for turnstile control PCB board connected to thecomputer control PCB board is external equipment of turnstile no...

Страница 14: ...green arrows in the direction Push arm and go through arm turn 120 degree Turn off power the arm will fall down 2 5 Notice of use Please keep the control button or remote control far away from the chi...

Страница 15: ...rd instruction No Port Sign Instructions 1 24V 24V input power supply to PCB board 2 GND 3 12V 12V power Output to Light bar counter and so on 4 GND 5 D1Ex NO USE 6 D2Ex 7 Man1 Entry button for manual...

Страница 16: ...close in place signal input once arm turn 120 degree it will give closing gate signal 28 POS 29 SW1 Entry opening signal input Dry contact signal and Access control PCB board entry opening relay signa...

Страница 17: ...S 0 0 0 1 1 0 3S 0 0 0 1 1 1 3 5S 0 0 1 0 0 0 4S 0 0 1 0 0 1 4 5S 0 0 1 0 1 0 5S 0 0 1 0 1 1 5 5S 0 0 1 1 0 0 6S 0 0 1 1 0 1 6 5S 0 0 1 1 1 0 7S 0 0 1 1 1 1 7 5S 0 1 0 0 0 0 8S 0 1 0 0 0 1 8 5S 0 1 0...

Страница 18: ...sure of the damper Operation should be carried out with the power supply disconnected check whether the damper oil spills check whether the force exerted by the spring is enough The force exerted by t...

Страница 19: ...1 Move the position senor inward Check connect wires to board 2 Adjust square solenoid or replace new one 3 Changing the square electromagnet 4 Replace a new board Q6 Didn t drop arm automatically wh...

Страница 20: ...djust the drop arm device to a suit position Q8 The rotating speed is too slow or fast Reasons Too slow is because the shock absorber over tight and too fast is too loose Solution Adjusting the shock...