background image

Tri-pod Turnstile • User Manual 

 

15 

10 

GND 

11 

A+ 

485 communication 

12 

B - 

13 

NO 

Entry relay normally open and normally close interface which also 
can connect entry counter 

14 

COM 

15 

NC 

16 

NO 

Exit relay normally open and normally close interface which also 
can connect exit counter 

17 

COM 

18 

NC 

19 

+12V 

+12 V power supply for arm drop down circular solenoid   

20 

GND 

21 

D1 

Entry LED indicator signal input   

22 

D2 

Exit LED indicator signal input 

23 

+12V 

+12 V power supply for indicator 

24 

GND 

25 

Down 

Testing for drop down function 

26 

Test 

27 

+12V 

Position sensor full close in place signal input,once arm turn 120 
degree , it will give closing gate signal   

28 

POS 

29 

SW1 

Entry opening signal input, Dry contact signal and Access control 
PCB  board  entry  opening  relay  signal  (NO  connect  SW1,  COM 
connect GND, and the relay time of access control board    should 
be set “0” or “1”

 

30 

GND 

31 

SW2 

Exit  opening  signal  input,  Dry  contact  signal  and  Access  control 
PCB  board  exit  opening  relay  signal  (NO  connect  SW2,  COM 
connect GND, and the relay time of access control board    should 
be set “0” or “1”

))

 

32 

GND 

33 

+24V 

Output  for  entry  square  solenoid,  normally  0v  t,  when  board 
recieve open singal,This port will be 24v output   

34 

GND 

35 

+24V 

Output  for  exit  square  solenoid,  normally  0v  t,  when  board 
recieve open singal,This port will be 24v output   

36 

GND 

 

 

Содержание DS-K3G4402 Series

Страница 1: ...AA Tripod Turnstile Quick Start Guide...

Страница 2: ...AND ERRORS HIKVISION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY SATISFACTORY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE THE USE OF THE PRODUCT BY YOU IS AT Y...

Страница 3: ...tion method for fingerprint device only fingerprint template will be saved which is impossible to reconstruct a fingerprint image As data controller you are advised to collect store process and transf...

Страница 4: ...must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE...

Страница 5: ...wer Source with 100 to 240 VAC or 12 VDC according to the IEC60950 1 standard Please refer to technical specifications for detailed information Do not connect several devices to one power adapter as a...

Страница 6: ...ct structure 7 1 4 2 Work principle 10 Chapter 2 Equipment Installations 10 2 1 Installation notes 10 2 2 Equipment Installation 10 2 3 Connection 12 2 4 Debugging instruction 12 2 5 Notice of use 13...

Страница 7: ...lectronic and mechanical rotation is a kind of advanced access controller After being integrated with RFIC IC and magnetic card it can meet various requirements of customers and therefore can be widel...

Страница 8: ...Operational voltage DC 24V 5 Voltage of indicator lamp DC12V 5 standard Working environment Indoor Working temperature 30 60 Humidity 5 90 Waterproof IP31 Installation interfaces for card readers 2 C...

Страница 9: ...ing cam The positioning cam is machined a guide way with a special profile In this guide way three points at a minimum distance from the centre are arranged at 120 intervals and correspond to the thre...

Страница 10: ...enoid tamper power supply NO Name Function 1 Access control device IC ID card access control fingerprint face recognition code reader access control device send delay signal to the turnstile board doo...

Страница 11: ...lease cut off the power The product must be earthed and an earth leakage breaker is necessary on the power supply The depth of buried PVC tube should be greater than 60mm and the exposed height above...

Страница 12: ...ng plate on the bottom of each turnstile 5 Drill hole by impact drill fix Expansion screws 6 Fix arm Before delivery we will dismantle two arm bar which can reduce some package cost and volume so befo...

Страница 13: ...lation we have completed connection of the circuit drive in the plate and provide 220 V for turnstile control PCB board connected to thecomputer control PCB board is external equipment of turnstile no...

Страница 14: ...green arrows in the direction Push arm and go through arm turn 120 degree Turn off power the arm will fall down 2 5 Notice of use Please keep the control button or remote control far away from the chi...

Страница 15: ...rd instruction No Port Sign Instructions 1 24V 24V input power supply to PCB board 2 GND 3 12V 12V power Output to Light bar counter and so on 4 GND 5 D1Ex NO USE 6 D2Ex 7 Man1 Entry button for manual...

Страница 16: ...close in place signal input once arm turn 120 degree it will give closing gate signal 28 POS 29 SW1 Entry opening signal input Dry contact signal and Access control PCB board entry opening relay signa...

Страница 17: ...S 0 0 0 1 1 0 3S 0 0 0 1 1 1 3 5S 0 0 1 0 0 0 4S 0 0 1 0 0 1 4 5S 0 0 1 0 1 0 5S 0 0 1 0 1 1 5 5S 0 0 1 1 0 0 6S 0 0 1 1 0 1 6 5S 0 0 1 1 1 0 7S 0 0 1 1 1 1 7 5S 0 1 0 0 0 0 8S 0 1 0 0 0 1 8 5S 0 1 0...

Страница 18: ...sure of the damper Operation should be carried out with the power supply disconnected check whether the damper oil spills check whether the force exerted by the spring is enough The force exerted by t...

Страница 19: ...1 Move the position senor inward Check connect wires to board 2 Adjust square solenoid or replace new one 3 Changing the square electromagnet 4 Replace a new board Q6 Didn t drop arm automatically wh...

Страница 20: ...djust the drop arm device to a suit position Q8 The rotating speed is too slow or fast Reasons Too slow is because the shock absorber over tight and too fast is too loose Solution Adjusting the shock...

Страница 21: ......

Отзывы: