background image

 

 

Swing Barrier

  

Quick Start Guide

 

ii 

 

Regulatory Information 
FCC Information 

Please take attention that changes or modification not expressly approved by the party responsible 

for compliance could void the user’s authority to operate the equipment. 

FCC compliance: This equipment has been tested and found to comply with the limits for a Class B 

digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 

reasonable  protection  against  harmful  interference  in  a  residential  installation.  This  equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference to radio communications. However, there is 

no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does 

cause  harmful  interference  to  radio  or television  reception,  which  can be  determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more 

of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the  equipment  into an  outlet  on  a  circuit  different from that  to  which  the  receiver  is 

connected. 

Consult the dealer or an experienced radio/TV technician for help. 

This  equipment  should  be  installed  and  operated  with  a  minimum  distance  20cm  between  the 

radiator and your body. 

FCC Conditions 

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two 

conditions: 

1. This device may not cause harmful interference. 

2.  This  device  must  accept  any  interference  received,  including  interference  that  may  cause 

undesired operation. 

EU Conformity Statement 

This product and - if applicable - the supplied accessories too are marked with "CE" 
and  comply  therefore  with  the  applicable  harmonized  European  standards  listed 

under  the  RE  Directive  2014/53/EU,  the  EMC  Directive  2014/30/EU,  the  RoHS 

Directive 2011/65/EU.   

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed 

of as unsorted municipal waste in the European Union. For proper recycling, return 

this product to your local supplier upon the purchase of equivalent new equipment, 

or  dispose  of  it  at  designated  collection  points.  For  more  information  see: 

www.recyclethis.info 

 

Содержание DS-K3B601-L Series

Страница 1: ...Swing Barrier Quick Start Guide...

Страница 2: ...ners No right of license is given to use such trademarks without express permission Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW HIKVISION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUD...

Страница 3: ...e the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the...

Страница 4: ...der Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio...

Страница 5: ...to clean and care the device by using the stainless steel cleaner It is suggested to clean the device every month Do not drop the device or subject it to physical shock and do not expose it to high e...

Страница 6: ...e of any failure occurred you need to return the device to the factory with the original wrapper Transportation without the original wrapper may result in damage on the device and lead to additional c...

Страница 7: ...8 3 4 4 Main Control Board Serial Port ID Description 11 3 4 5 RS 485 Wiring 12 3 4 6 RS 232 Wiring 13 3 4 7 Wiegand Wiring 14 3 4 8 Barrier Control Wiring 14 3 4 9 Alarm Output Wiring 16 3 5 Wiring L...

Страница 8: ...Swing Barrier Quick Start Guide vii DIP Switch Corresponded Functions 26 Appendix B Table of Audio Index Related Content 28 Appendix C Error Code Description 29...

Страница 9: ...locked or stop working when people are nipped Anti forced accessing The barrier will be locked automatically without open barrier signal It can bear the force of up to 120 Nm Self detection Self diag...

Страница 10: ...ble surfaces If the installation area is too close to the wall make sure the distance between the pedestal and the wall should be no more than 120 mm or you cannot open the pedestal s top panel Steps...

Страница 11: ...d exit marks on the pedestals move the pedestals to the corresponded positions Note Make sure the installation holes on the pedestals and the base are aligned with each other 6 Secure the pedestals wi...

Страница 12: ...the swing barrier to the AC electric supply Note The voltage fluctuation of the electric supply is between 100 VAC and 220 VAC 50 to 60 Hz The picture displayed below describes each component s positi...

Страница 13: ...erconnecting Cable Purpose You should use interconnecting cables to connect the master lane board and the slave lane board for components communication The picture displayed below describes the interc...

Страница 14: ...igh voltage conduit General burying method Bury one network cable and one AC power cord for the right pedestal and bury one network cable and one AC power cord for the central pedestal before installa...

Страница 15: ...antenna motor drive interface brake interface power interface battery interface DIP switch and seven segment display Note For detailed information about the DIP switch see Appendix A DIP Switch Descr...

Страница 16: ...Swing Barrier Quick Start Guide 8 3 4 3 Main Control Board Terminal Description...

Страница 17: ...Control Output Valid Card Output BZ Card Reader Buzzer Control Output W1 Wiegand Head Read Data Input Data1 W0 Wiegand Head Read Data Input Data0 GND Grounding RS 485 Interface GND Grounding RS 485 B...

Страница 18: ...oor relay output The DIP of RS485 card ID is set as 1 and4 by default 1 is for entering and 4 is for exiting Set the DIP as 3 for connecting visitor card reader The Wiegand card reader 1 and 2 respect...

Страница 19: ...are as follows UART2 UART3 Jumper Cap Reserved serial port Use the jumper cap to switch the serial port communication mode You can switch between the RS 485 communication mode and the RS 232 communica...

Страница 20: ...cation mode If wiring other controllers compatible with Hikvision communication protocol use the jumper cap to switch between RS 485 and RS 232 communication mode UART4 The serial port is in the wirin...

Страница 21: ...bout text screen see Configuring Screen Parameters in User Manual of iVMS 4200 Client Software 3 4 6 RS 232 Wiring Note There are three RS 232 interfaces UART4 UART7 and UART8 UART7 and UART8 can conn...

Страница 22: ...der 3 4 8 Barrier Control Wiring Purpose By default the barrier has connected with the main control board The lane control board can control the barrier status If possible the device can connect with...

Страница 23: ...Swing Barrier Quick Start Guide 15 Entering Wiring Exiting Wiring...

Страница 24: ...off The battery interface position is as follows Before you start Ask our technique support and sales and purchase for the lithium battery Steps 1 Install lithium batteries 1 Remove the screws on the...

Страница 25: ...Swing Barrier Quick Start Guide 17...

Страница 26: ...fault the memory mode is enabled When multiple cards are swiped and authenticated it allows multiple persons passing through the lane When it counts the passing people number is equal to the card swip...

Страница 27: ...nds The indicator of the remote control will flash twice if the pairing is completed 5 Set the DIP switch as OFF and reboot the swing barrier to take effect Notes You can also pair the remote control...

Страница 28: ...in RS 232 communication mode 4 5 Switching Relay Output Mode NO NC 4 5 1 Barrier Control Relay Output Mode The pins of the barrier control relay on the main control board is as below The jumper cap s...

Страница 29: ...Swing Barrier Quick Start Guide 21 4 5 2 Alarm Relay Output Mode NO NC Alarm Relay Output Mode NO Alarm Relay Output Mode NC...

Страница 30: ...default user name admin 5 1 Activating via SADP Software SADP software is used for detecting the online device activating the device and resetting the password Get the SADP software from the supplied...

Страница 31: ...ave the password 5 Check the activated device You can change the device IP address to the same network segment with your computer by either modifying the IP address manually or checking the checkbox o...

Страница 32: ...face 6 In the pop up window create a password in the password field and confirm the password STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own choosing using a m...

Страница 33: ...lick the Modify Netinfor button to pop up the Network Parameter Modification interface 9 Change the device IP address to the same network segment with your computer by either modifying the IP address...

Страница 34: ...8 bit DIP switch corresponded functions on the master lane control board are as follows Bit Function Decimal Value Binary Value 1 to 2 Normal Mode 0 00 Study Mode 1 01 Test Mode 2 10 3 Enable Memory...

Страница 35: ...Quick Start Guide 27 The 4 bit DIP switch corresponded functions on the master lane control board are as follows Bit Function Decimal Value Binary Value 1 Normal Mode 0 0 Remote Control Paring Mode 1...

Страница 36: ...Index Content 1 Authenticated 2 Card No does not exist 3 Card No and fingerprint mismatch 4 Climbing over the barrier 5 Reverse passing 6 Passing timeout 7 Intrusion 8 Force accessing 9 Tailgating 10...

Страница 37: ...5 Offline 17 The Second IR Beam on IR Board 2 Triggered 04 IR Board 6 Offline 18 The First IR Beam on IR Board 3 Triggered 05 Light Board Offline Entrance 19 The Second IR Beam on IR Board 3 Triggere...

Страница 38: ...Swing Barrier Quick Start Guide 30 UD08976B B...

Отзывы:

Похожие инструкции для DS-K3B601-L Series