background image

4

Regulatory Information

This product and - if applicable - the supplied 

accessories too are marked with "CE" and 

comply therefore with the applicable 

harmonized European standards listed under 

the RE Directive 2014/53/EU, the EMC 

Directive 2014/30/EU, the RoHS Directive 

2011/65/EU. 

2012/19/EU (WEEE directive): Products marked 

with this symbol cannot be disposed of as 

unsorted municipal waste in the European 

Union. For proper recycling, return this product 

to your local supplier upon the purchase of 

equivalent new equipment, or dispose of it at 

designated collection points. For more 

information see: 

www.recyclethis.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as 

unsorted municipal waste in the European Union. See the product documentation for specific 

battery information. The battery is marked with this symbol, which may include lettering to 

indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to 

your supplier or to a designated collection point. For more information see: 

www.recyclethis.info

Industry Canada ICES-003 Compliance

This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. 

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 

(1) this device may not cause interference, and

(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux 

conditions suivantes :

(1) l'appareil ne doit pas produire de brouillage, et

(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the 

transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent 

isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut

fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les 

risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope 

rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.

This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.

Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps.

FCC Conditions

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired operation.

EU Conformity Statement

Configuration

Device Wiring 

Attendance Configuration

3

2

Access Control System Configuration

User Management

1

Note: 

The external power supply and the access control terminal should use the same GND cable.

Manage User: 

In the New (New User) interface, enter 

the new user ID No., the user name, the card No. Register 

the fingerprint, set the password, select the department, 

set the user permission, select schedule template, set the 

authentication mode and set the duress card. Save the 

parameters to confirm adding.

ACS System Configuration: 

In the ACS Parameters Setting interface, configure the terminal authentication mode, the sub reader authenti

-

cation mode, the door magnetic status, the lock action time, the door-open timeout alarm, the maximum 

times for authentication and the anti-passback.

Holiday Group Configuration: 

In New (New Holiday Group) interface, enter a new holiday group name. Select New ACS Holiday and enter 

the holiday No., the holiday name, the holiday start time and the holiday end time. Save the parameters to 

confirm adding.

Week Plan Configuration: 

In the Week Plan menu, select New (New Week Plan) to configure the week plan parameters, including the 

No., the name, the week plan time and the corresponding periods. Save the parameters to confirm adding.

Schedule Template Configuration: 

In the Schedule Template menu, select New (New Schedule Template) to configure the schedule template 

parameters, including the template No., the template name, the week plan and the holiday group. Save the 

parameters to confirm adding.

Configure the shift via the device. You are able to 
schedule shift by department or by individual depending 
on the user property. The working flows are as follows:

Scheduling Shift by Department:

 

Add User (See 

Step 1) - Edit Department - Configure Shift - Add Holiday - 
Configure Shift Schedule (by Department).

Edit Department: 

Select a department to edit in the department list. Select “Edit”and edit the department name, shift type and shift name. Save the parameters 

Configure Shift

Normal Shift: In the Normal Shift interface, configure the attendance rule, the normal shift attendance. Save the parameters to confirm setting.

Man-Hour Shift: In the Man-Hour Shift interface, configure the man-hour shift parameters. Save the parameters to confirm setting.

Add Holiday

 

In the New (New Holiday) interface, enter the holiday No, the holiday name, the holiday start time and the holiday end time. Save the parameters to confirm adding.

Configure Shift Schedule 

Schedule Shift by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shift, the start date, the end date and 

the holiday. Save the parameters to confirm configuration.

Schedule Shift by Individual: Select New Individual Shift in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shift 

interface. Configure the shift, the schedule start date and the end date. Save the parameters to confirm editing.

User Management

ACS Configuration

Attendance 

Configuration

External Device Wiring Overview (Without Secure Door Control Unit)

External Device Wiring Overview (With Secure Door Control Unit)

Door Status 

Input

Power Input

SENSOR

BUTTON

B1

B2

B3

B4

Green/Brown

Black

Green/Black

Black

Lock Output

NC

C1

C2

C3

COM

NC

White/Purple

White/Black
White/Red

Red
Black

Door Magnetic

Exit Button

NO

Power

Electric Dropbolt/

Magnetic Lock

Electric Strike

Secure Door Control Unit

Wiring Terminal

Note: 

The external power supply and the secure door control terminal should use the same GND cable.

Attendance Report

Plug the USB disk in the device. In Report interface of Attendance interface, select a table type to export. Press the OK key to export the attendance report to the USB disk.
The device will automatically check the USB disk memory. If there is no enough space for exporting, a prompt will be displayed. You are able to configure the record over 
threshold prompt and record delete function in the System interface.

Record over Threshold Pop up Prompt (%):

 

If the attendance record memory reaches the configured value, the system will pop up a prompt to remind you. If 

configure the threshold to 99%, the system will pop up a prompt to remind you to delete the attendance data when the capacity reaches the threshold. The available 
value: 1 to 99.

Record Delete:

 

When the function is enabled, the terminal will delete the first 3000 attendance records when the memory is full, in order to save the new attendance 

records. By default, the function is enabled. See Section 5.2 Attendance Record Delete Rule in the User Manual of Fingerprint Time Attendance Terminal. 

5

FCC Information

Please take attention that changes or modification not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

FCC compliance: 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, uses and 

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

—Consult the dealer or an experienced radio/TV technician for help.

This equipment should be installed and operated with a minimum distance 20cm between the radiator 

and your body.

Scheduling Shift by Individual:

 

Add User (See Step 1) - Configure Shift - Add Holiday - Configure Shift Schedule (by Individual).

User Management, Access Control System Configuration 

and Attendance Configuration are three main parts of the 

Access Control Terminal.