DS-K1106 Series Card Reader
User Manual
UD.6L0206D1175A01
Страница 1: ...DS K1106 Series Card Reader User Manual UD 6L0206D1175A01...
Страница 2: ...using and managing the product Pictures charts images and all other information hereinafter are for description and explanation only The information contained in the Manual is subject to change witho...
Страница 3: ...RODUCT SHALL BE WHOLLY AT YOUR OWN RISKS HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION...
Страница 4: ...PTER 2 INTRODUCTION 3 2 1 FRONT VIEW 3 2 2 REAR VIEW 4 CHAPTER 3 INSTALLATION 4 3 1 INSTALLING PSAM CARD 4 3 2 INTRODUCTION FOR DIP SWITCH 5 3 3 DEFINITION OF CABLE 6 3 4 WIRING CABLES 7 3 5 INSTALLIN...
Страница 5: ...range 10 10 DC power supply which is nonswitched and linear To guarantee the communication between the controller and the card reader you must use RVVP cable above 0 5 to connect them If the card rea...
Страница 6: ...unicates with access controller via either RS 485 protocol or Wiegand protocol And a build in tamper proof module helps to protect card reader from malicious damage As to the physical appearance the P...
Страница 7: ...available for CPU card reader 2 DIP Switch 3 Cable Interface of RS 485 Power LED Control etc 4 Serial Port Chapter 3 Installation 3 1 Installing PSAM Card PSAM card slot is only available for CPU card...
Страница 8: ...of DIP switch from left to right is 1 8 Figure 3 2 DIP Switch Module Table 3 1 Description of DIP Switch Icon Description Represent 1 in binary mode Represent 0 in binary mode For example binary valu...
Страница 9: ...f 34 bit 8 Matched Resistance available for RS 485 protocol 1 Enable 0 Disable 3 3 Definition of Cable The description of 10 cables is shown below Table 3 3 Description of Cable Color Description Yell...
Страница 10: ...s to establish the communication between them Steps for RS 485 communication mode 1 Set the DIP switch of No 6 as 0 2 Set the DIP switch of No 1 5 for RS 485 address and reading card mode For details...
Страница 11: ...Communication Mode Steps for Wiegand communication mode 1 Set the DIP switch of No 6 as 1 2 Set the DIP switch of No 5 and 7 for reading card mode and Wiegand protocol For details please refer to 3 2...
Страница 12: ...ader Black Red Green White Purple Orange Brown der Card Reader Green Figure 3 5 Wiring for Wiegand Communication Mode 3 5 Installing Card Reader Before you start Set the DIP switch For details refer t...
Страница 13: ...ten the screw to keep the components together 5 Fix the side cover onto the card reader press the cover to make it tightly fit the reader Chapter 4 Sound Prompt and Indicator After the card reader is...
Страница 14: ...e slow beeps The operation of pressing keys or swiping card is invalid Rapidly continuous beeps Alarm of tamper proof Slowly continuous beeps The card reader is unencrypted Table 4 2 Description of LE...
Страница 15: ...12...