Table 1-2

 

Description of LED Indicator 

LED Indicator Status 

Description 

Green  (blink  for  1 
time), and red (blink 
for 3 times) 

The card reader is power on.   

Green and blinking 

For  Card  +  Fingerprint  authentication: 
prompt  for  pressing  the  fingerprint  after 
swiping the card. 
The 

operation 

of 

configuring 

the 

fingerprint.   

Solid green for 2s 

The  operation  of  pressing  keys  or  swiping 
card is valid. 

Solid red 

Card reader is working normally. 

Red  and  blink  for  3 
times 

The  operation  of  pressing  keys  or  swiping 
card is invalid. 

Red and blinking 

For  RS-485  protocol:  Registering  failed  or 
card reader is offline. 

 

Содержание DS-k1106

Страница 1: ...DS K1107 Series Card Reader User Manual UD05519B...

Страница 2: ...using and managing the product Pictures charts images and all other information hereinafter are for description and explanation only The information contained in the Manual is subject to change witho...

Страница 3: ...RODUCT SHALL BE WHOLLY AT YOUR OWN RISKS HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION...

Страница 4: ...range 10 10 DC power supply which is nonswitched and linear To guarantee the communication between the controller and the card reader you must use RVVP cable above 0 5 to connect them If the card rea...

Страница 5: ...oduct with a 32 bit high speed processor It communicates with access controller via either RS 485 protocol AES encrypted or Wiegand protocol And a build in tamper proof module helps to protect card re...

Страница 6: ...2 Indicator and Component Figure 2 2 2 2 Indicator and Component Chapter 3 Installation 3 1 Introduction for DIP Switch The DIP switch module is shown below The No of DIP switch from left to right is...

Страница 7: ...00 Figure 3 2 DIP Switch Module Table 3 2 Description of DIP Switch No Description DIP Switch Status 1 4 Address of RS 485 1 1 0 0 5 Reserved Reserved 6 Wiegand protocol or RS 485 protocol 1 Wiegand p...

Страница 8: ...TAMPER available for Wiegand Protocol Purple Beep Control available for Wiegand Protocol Brown Green LED Control available for Wiegand Protocol 3 3 Wiring Cables Purpose Wire the cables between contro...

Страница 9: ...RS 485 Communication Mode Steps for Wiegand communication mode 1 Set the DIP switch of No 6 as 1 2 Set the DIP switch of No 7 for reading card mode and Wiegand protocol For details please refer to 3...

Страница 10: ...er Black Red Green White Purple Orange Brown Card Reader Green Figure 3 4 Wiring for Wiegand Communication Mode 3 4 Installing Card Reader Before you start Set the DIP switch For details refer to 3 1...

Страница 11: ...in the right direction 3 Slide the card reader from the direction A to B along the plate side until the bottom matches the joint Make sure the card reader is tightly on the wall or other places 4 Dra...

Страница 12: ...ription One beep Swiping card prompt Pressing keys prompt Prompt for too long card No input by pressing keys Time out prompt for pressing keys or swiping card For Card Fingerprint authentication promp...

Страница 13: ...ntication prompt for pressing the fingerprint after swiping the card The operation of configuring the fingerprint Solid green for 2s The operation of pressing keys or swiping card is valid Solid red C...

Страница 14: ...12...

Отзывы: