4        Installation Guide 

- DS-8100-S Series DVR

 

Note:

 

The RS-485 PTZ control should be connected with 

the T+ and T- pin on the RS-485 terminal block. 

 

Controller Connection 

 

To connect a controller to the DVR: 

1. 

Disconnect 

pluggable block 

from the KB terminal block. 

2. 

Unfasten stop screws from the KB D+, D- 

pluggable 

block

, insert signal cables into slots and fasten stop 

screws. Ensure signal cables are in tight. 

3. 

Connect Ta on controller to D+ on terminal block and Tb 

on controller to D- on terminal block. Fasten stop screws. 

4. 

Connect 

pluggable block 

back into terminal block. 

Note: 

Make sure both the controller and DVR are grounded. 

 

HDD Storage Calculation 

Chart 

 

The following chart shows an estimation of storage space 

used based on recording at one channel for an hour at a fixed 

bit rate. 

 

Bit Rate

 

Storage Used

 

96K

 

42M

 

128K

 

56M

 

160K

 

70M

 

192K

 

83M

 

224K

 

98M

 

256K

 

112M

 

320K

 

140M

 

384K

 

168M

 

448K

 

196M

 

512K

 

225M

 

640K

 

281M

 

768K

 

337M

 

896K

 

393M

 

1024K

 

450M

 

1280K

 

562M

 

1536K

 

675M

 

1792K

 

787M

 

2048K

 

900M

 

 

Note: 

Please note that supplied values for storage space 

used is just for reference. Storage space used is estimated by 

formulas and may have some deviation from actual value. 

Содержание DS-8100-S Series

Страница 1: ...es 3 When installing cables ensure that the bend radius of the cables are no less than five times than it s diameter 4 Connect both the alarm and RS 485 cable 5 Allow at least 2cm 0 75in of space between racks mounted devices 6 Ensure the DVR is grounded 7 Environmental temperature should be within the range of 10º C 55º C 14º F 131º F 8 Environmental humidity should be within the range of 10 90 H...

Страница 2: ...ed with VIDEO OUT 4 LINE IN BNC connector for audio input 5 VGA VGA output Display local video output and menu 6 RS232 DB9 connector for RS232 7 LAN Interface Connector for LAN Local Area Network 8 USB Interface Connector for USB devices 9 Termination Switch RS 485 termination switch Up position is not terminated Down is 120Ω termination 10 RS 485 Interface Connectors for RS 485 devices T T pin co...

Страница 3: ...with one alarm output By default jumpers are connected To connect an AC load jumpers should be removed Note An external relay is needed to prevent electric shock when connecting to an AC load Alarm Connection To connect alarm devices to the DVR 1 Disconnect pluggable block from the ALAM IN ALARM OUT terminal block 2 Unfasten stop screws from the pluggable block insert signal cables into slots and ...

Страница 4: ...on terminal block Fasten stop screws 4 Connect pluggable block back into terminal block Note Make sure both the controller and DVR are grounded HDD Storage Calculation Chart The following chart shows an estimation of storage space used based on recording at one channel for an hour at a fixed bit rate Bit Rate Storage Used 96K 42M 128K 56M 160K 70M 192K 83M 224K 98M 256K 112M 320K 140M 384K 168M 44...

Отзывы: