DS-7700NI-
SP/9000/9600 Series HDVR/NVR User’s Manual
156
2.
Select an array and click
to delete the array.
3.
In pop-up attention box, click the Yes button to confirm the array deletion.
Note:
Deleting array will cause to delete all the data in the array.
Migrating and Expanding
When the remaining storage space is lower than the actual needs, you can take array migration
and online expansion to enlarge the capacity of the virtual disk. At least one available physical
disk should exist for the array migration.
To migrating and expanding:
1.
Enter the Physical Disk interface by going to Menu > System Configuration > RAID >
Physical Disk to confirm at least one available physical disk has existed for the array
migration.
2.
Select Array tab to enter the Array interface.
3.
Select the array to be migrated and click
to enter the Migrate Array interface.
Figure 183 Migrate Array Interface
4.
Select the available physical disk and click OK to confirm the settings.
5.
There will pop up an attention box with these words: Do not unplug the physical disk
when it is under rebuilding. Click OK to start rebuilding.
6.
You can enter the Array interface and Virtual Disk interface to check the process of the
migration.
Figure 184 Array Interface
Содержание DS-7700NI-SP Series
Страница 13: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 13 Figure 5 DS 9000HWI ST DS 9000HFI RT ...
Страница 33: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 33 Figure 28 Confirmation Window ...
Страница 42: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 42 Figure 42 Strong Acceptable Strength Password ...
Страница 51: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 51 Figure 52 HDD Information Menu ...
Страница 104: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 104 Figure 111 Main Menu ...
Страница 134: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 134 Figure 152 POS Setting ...
Страница 159: ...DS 7700NI SP 9000 9600 Series HDVR NVR User s Manual 159 Figure 190 Upgrade Interface ...