Thermal Network Camera User Manual
47
Steps
1. Go to picture overlay setting page: Configuration → Image → Picture Overlay.
2. Click Browse to select a picture, and click Upload.
The picture with a red rectangle will appear in live view after successfully uploading.
3. Check Enable Picture Overlay.
4. Drag the picture to adjust its position.
5. Click Save.
9.6 Set Manual DPC (Defective Pixel Correction)
If the amount of defective pixels in the image is comparatively small and accurate correction is
needed, you can correct these pixels manually.
Steps
1. Go to Configuration → Image → DPC.
2. Select manual mode.
3. Click the defective pixel on the image, then a cursor shows on the live view.
4. Click Up, Down, Left, Right to adjust the cursor position to the defective pixel position.
5. Click
, then click
to correct defective pixel.
Note
If multiple defective pixels need to be corrected, click
after locating a defective pixel. Then
after locating other pixels, click
to correct them simultaneously.
6. Optional: Click
to cancel defective pixel correction.