background image

                                                                                                                                                                       

 

4)

 

Counting Status: It displays the current status of the camera. There are three types optional: 
Counting, Stopped, Pause counting. You can click Refresh button to refresh the status. 

Counting: Count normally. 

Stopped: Disable people counting function. 

Pause counting: The scene is too dark. 

5)

 

Clear Storage Data: To clear stored data on camera, you can click the Clear button. Always do 
the operation with caution. Deleted data cannot be restored. 

6)

 

One-touch Export: Export the device hardware settings, installation settings, people counting 
settings, rule settings and advanced settings. 

7)

 

Maintenance Mode: If the function is enabled, certain camera settings will be changed, such as 
the resolution, frame rate and bit rate. When we need collect the video clip for the issue 
analyse, it is necessary to enable the maintenance mode. 

 

Chapter 3. Application scenario 

The application scenario and the mounting position are very important to the people counting 
accuracy. Usually the camera is mounted above the passageway and the door. Below shows the 
mounting position and configuration for two typical examples:   

 

Mounting position and configuration for supermarket 

Содержание DS-2CD6825G0

Страница 1: ...Installation and Configuration Guide for Dual lens People Counting Camera...

Страница 2: ...f introduction 3 Chapter 2 Installation specification 4 2 1 Focal length and counting width 4 2 2 Accessaries 7 2 3 Installation steps 7 2 4 Counting configuration 12 Configuration for single camera 1...

Страница 3: ...ects within the monitoring scope analyze the trajectory data and achieve high precision people counting It is very suitable for places where people counting is needed such as shopping mall supermarket...

Страница 4: ...height m ft Max counting width m ft Max counting depth m ft 2 0 066 2 1 6 9 1 02 3 3 0 58 1 9 2 2 7 3 1 28 4 2 0 72 2 4 2 3 7 5 1 54 5 1 0 86 2 8 2 4 7 9 1 79 5 9 1 01 3 3 2 5 8 2 2 05 6 7 1 15 3 8 2...

Страница 5: ...6 4 21 3 6 11 8 4 3 14 1 6 66 21 9 3 74 12 3 4 4 14 4 6 91 22 7 3 89 12 8 4 5 14 8 7 17 23 5 4 03 13 2 4 6 15 1 5 5 18 3 08 10 1 4 7 15 4 5 69 18 7 3 19 10 5 4 8 15 7 5 88 19 3 3 3 10 8 4 9 16 1 6 07...

Страница 6: ...Focal length mm ft Installation height m ft Max counting width m ft Max counting depth m ft 5 8 19 7 78 25 5 4 36 14 3 5 9 19 4 7 97 26 1 4 47 14 7 6 19 7 8 16 26 8 4 57 15...

Страница 7: ...Camera Drill Template Screws Quick guide 2 3 Installation steps Please pay great attention to the mounting position Inappropriate mounting position may cause loss of accuracy The recommended mounting...

Страница 8: ...Horizontal sketch map of mounting position Vertical sketch map of mounting position Effect picture after installation Keep HIKVISION logo in the same direction as the Front arrow see picture below...

Страница 9: ...senger flow 90 vertical by the ground see picture below Passenger flow perpendicular to the door For some scenarios where there are multiple cameras mount the cameras according to two rules Rule one I...

Страница 10: ...ween each camera according to the overlap see the yellow area below of the adjacent two cameras counting width The suggested overlapping length is between 0 2 0 5m Sketch map of multiple cameras insta...

Страница 11: ...mount one camera right above 4 The camera should be mounted as close as possible to the passageway without obstacle Remove the obstacle or adjust the camera mounting position if there is obstacle belo...

Страница 12: ...select the VCA source as People Counting Mode Step 2 Rule Configuration 1 Enter VCA People Counting check Enable People Counting 2 Select the calibration mode Manual and Auto are selectable Manual Ca...

Страница 13: ...is the true value in vertical direction between the lens and the ground Auto Calibration Mode It will generate the lens height and a green calibration area automatically The calibration area is used...

Страница 14: ...bration fails switch to Manual and input the measured Height then click Calibration 2 The detection area should be flat avoid uneven area like steps or slope Step 3 NOTE The rule frame should be withi...

Страница 15: ...he yellow line should be within the blue detection region Detection Region Draw A and B region Make sure the two areas don t overlap If the target enters from A region to B region then it is counted a...

Страница 16: ...Step 5 Save it after finishing the configuration Set the Arming schedule and linkage method...

Страница 17: ...jacent lines Some objects could be placed on the image border for reference See picture below Configuration of each detection line Parameter description Reverse Counting Alarm Set reverse counting ala...

Страница 18: ...istics data as required 1 5 10 15 20 30 60 minutes are optional 4 We can send the report via email the data type includes Daily Weekly Monthly Annual report The report format includes excel csv txt xm...

Страница 19: ...set up a daily reset time Or you can reset the OSD counter manually by click Manual Reset 4 Display VCA Info on Stream It will display the ID number and height information of tracking people on strea...

Страница 20: ...rily Algorithm Validity The bigger the numerical value the stricter the object detection requirements are we recommend to use default values It is recommended to use default type depth map mainly and...

Страница 21: ...e hardware settings installation settings people counting settings rule settings and advanced settings 7 Maintenance Mode If the function is enabled certain camera settings will be changed such as the...

Страница 22: ...Mounting position and configuration for subway...

Отзывы: