background image

Safe Use Locations

This device should only be operated in an above-ground, open-air situation where there is natural 

ventilation, no stagnant areas, and where gas leakage and/or products of combustion will be promptly 

diffused by wind.

Any enclosure in which you are using this device should comply with one of the following types of safe use 

locations. Do not use this device in any area that does not comply with any of the following safe use locations.

 

• An enclosure with walls on all sides, but no roof/overhead covering.

 

• A partial enclosure that includes a roof/overhead covering but has no more than two (2) walls.

 

• A partial enclosure with a roof/overhead covering, more than two (2) walls, but meets one of the 

             following conditions:

 

• At least 25% of the total wall area is completely open and ventilated.

 

• At least 30% or more of the remaining wall side, back, and front areas are completely open and 

             unrestricted.

 

• If using on a balcony or patio, at least 20% or more of the total wall area must remain open and 

             restricted.

During operation, always make sure that all air inlets and exhaust vents are kept unobstructed and fully open.

Safety Features

High Temperature Sensor: The device will automatically disable the burner once the water temperature from 

the dispenser reaches 125 

°

F (52 

°

C). It will automatically relight the burner once the water temperature 

from the dispenser falls below 113 

°

F (45 

°

C).

Water Flow Sensor: Water must be flowing through the system in order for the burner to ignite. If the water 

supply becomes restricted or ceases entirely (i.e. the Flow Switch is in the “off” position), the burner will 

automatically be extinguished and will not relight until the water flow resumes.

Tilt Switch: If this device is moved during operation or is being operated on an unstable surface, the 

appliance will shut down and must be switched off until placed in a suitable location.

Fuse Protection: Fuses are located in the cigarette lighter and pump power inlet. In the event of an issue 

with the electrical supply, the fuse will blow and protect the electronic system of this device.

PACKAGE CONTENTS

 

•  Portable water heater

 

•  Carrying case

 

•  Gas regulator

 

•  Pump hose and plug

 

•  Shower head attachment

 

•  AC/DC adapter

 

•  12 V DC power adapter

4

Содержание HICPSBT

Страница 1: ...Portable Water Heater USER GUIDE HICPSBT...

Страница 2: ...this device Do not place or store the device near anything flammable such as chemicals or aerosol sprays Do not operate this device if any panels covers or safeguards are missing or are not operating...

Страница 3: ...iance while it is in operation Always extinguish the burner allow the device to cool and disengage the propane tank before moving the device Always use the approved gas regulator that came with the de...

Страница 4: ...ed During operation always make sure that all air inlets and exhaust vents are kept unobstructed and fully open Safety Features High Temperature Sensor The device will automatically disable the burner...

Страница 5: ...Faucet mount Control panel Water outlet Battery charge level Gas regulator Burner indicator Front carry handle Water inlet temperature Power on off Gas temperature control Power input Water outlet te...

Страница 6: ...p power attachment 4 AC DC adapter attachment 5 12V DC power adapter attachment 6 Faucet mount attachment 3 Shower head attachment 6 connection point 1 Gas inlet connection point 4 Main DC power input...

Страница 7: ...solid non combustible surface Straighten out all hoses and remove any kinks or twists 2 Screw the gas regulator attachment 1 in a clockwise direction onto the gas inlet connection point 1 on the back...

Страница 8: ...ad flow switch to the on position USING THE SHOWER 1 Power on the unit 2 Check the Battery Charge Level to see if sufficient power is available If not connect to the AC or DC adaptor attachment 4 3 Po...

Страница 9: ...make sure it is safe to use Once the user has finished using the device slide the Flow Switch to the off position and press the START button to stop the flow of water to the device FAUCET SETUP To run...

Страница 10: ...the device is in operation Charging time will increase by 50 if the device is in operation while charging To charge the 12 V 3 2 A hr battery use the AC DC power adapter attachment 4 The 12 V DC cigar...

Страница 11: ...X Check source water temperature Recycle the water through the device back into the source reservoir and through the appliance again Check gas Temperature Control is set on MIN Check source water temp...

Страница 12: ...ot lit Over temperature shut off Tilt switch activated place on level surface and re start appliance Error Code Code Meaning Dimensions H x L x W 11 8 x 9 65 x 12 2 30 x 24 5 x 31 cm Weight 13 2 lbs 6...

Страница 13: ...fect at no charge using new or refurbished replacement parts 2 exchange the Product with a Product that is new or which has been manufactured from new or serviceable used parts and is at least functio...

Страница 14: ...RE THAN ONE INCIDENT OR CLAIM THE COMPANY DISCLAIMS ALL LIABILITY OF ANY KIND OF ITS LICENSORS AND SUPPLIERS IN NO EVENT WILL THE COMPANY OR ITS LICENSORS MANUFACTURERS AND SUPPLIERS BE LIABLE FOR ANY...

Отзывы: