25
Ordercode: 200201
TF-300 Fresnel CW
No Response to DMX
Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction.
01)
Check the DMX setting. Make sure that DMX addresses are correct.
02)
Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03)
Determine whether the controller or light effect is at fault. Does the controller operate properly with
other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light
effect to a qualified technician.
Problem
Probable cause(s)
Remedy
One or more
fixtures do not
function at all
No power to the fixture
●
Check if power is switched on and
cables are plugged in
Internal fuse blown
●
Return the Fresnel to your Infinity dealer
Fixtures reset
correctly, but all
respond erratically
or not at all to the
controller
The controller is not connected
●
Connect controller
3-pin/5-pin XLR Out of the
controller does not match XLR Out
of the first fixture on the link (i.e.
signal is reversed)
●
Install a phase reversing cable
between the controller and the first
fixture on the link
Fixtures reset
correctly, but
some respond
erratically or not at
all to the controller
Poor data quality
●
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link
Bad data link connection
●
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables
Data link not terminated with 120
Ohm termination plug
●
Insert termination plug in output jack of
the last fixture on the link
Incorrect addressing of the fixtures
●
Check address setting
One of the fixtures is defective and
disturbs data transmission on the
link
●
Bypass one fixture at a time until
normal operation is regained: unplug
both connectors and connect them
directly together
●
Have the defective fixture serviced by
a qualified technician
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed)
●
Install a phase-reversing cable
between the fixtures or swap pin 2 and
3 in the fixture that behaves erratically
No light or LEDs cut
out intermittently
Fixture is too hot
●
Allow fixture to cool
●
Clean fan
●
Make sure air vents are not blocked
●
Turn up the air conditioning
LEDs damaged
●
Disconnect fixture and return to your
dealer
The power supply settings do not
match local AC voltage and
frequency
●
Disconnect fixture. Check settings and
correct if necessary
Содержание 200201
Страница 3: ...2 Ordercode 200201 TF 300 Fresnel CW Product Specifications 26 Dimensions 27 Notes 28...
Страница 17: ...16 Ordercode 200201 TF 300 Fresnel CW Menu Overview...
Страница 28: ...27 Ordercode 200201 TF 300 Fresnel CW Dimensions...
Страница 29: ...28 Ordercode 200201 TF 300 Fresnel CW Notes...
Страница 30: ...29 Ordercode 200201 TF 300 Fresnel CW...
Страница 31: ...30 Ordercode 200201 TF 300 Fresnel CW...
Страница 32: ...2019 Infinity...