background image

4

Thank you for choosing a wood heater from High Valley Stove.  Safe and e

  cient opera  on of your wood heater depends 

greatly on proper installa  on as outlined in this owner’s manual.  If this wood heater is not properly installed, a house 

fi

 re may result.  To reduce the risk of 

fi

 re follow all instruc  ons, cau  ons, and safety no  ces contained herein.  Installa-

 on must also meet all State and Local Code requirements and/or restric  ons.  Check with your local Building O

  cial, 

Fire O

  cial, or other Authority Having Jurisdic  on (AHJ) regarding the need to obtain a permit prior to installing a wood 

heater; and whether an inspec  on of the installa  on is required upon comple  on.  Understand that code requirements 
and follow-up inspec  on are not put in place to make the installa  on process more di

  cult.  Rather they are designed 

to help ensure your safety.  Don’t take shortcuts, use or allow makeshi   methods, or other compromises in the instal-
la  on.  Safety is paramount and the key to enjoying your new wood heater.  We strongly recommend installa  on by an 
experienced professional installer who has the specialized knowledge, tools, and equipment to complete the installa  on 
safely.  Look for an installer who is cer  

fi

 ed by the The Na  onal Fireplace Ins  tute (NFI) as a Woodstove Specialist or 

Master Hearth Professional (MHP) to have demonstrated their mastery of the knowledge required in all phases of safe 
woodstove installa  on, and of best current industry prac  ces.  Be sure to contact your insurance company to inquire 
whether they have addi  onal requirements.

BURN SOLID WOOD FUEL ONLY. 

 This wood 

heater is designed and approved for the burning of 
cord wood fuel only.  Burning any type of fuel oth-
er than cord wood in this wood heater is against all 
safety tes  ng and will void all warran  es.

DO NOT USE CHEMICALS OR FLUIDS TO 
START THE FIRE.

 

 

Never use gasoline, gasoline-

type lantern fuel, kerosene, charcoal lighter 

fl

 uid, or 

similar liquids to start or “freshen up” a 

fi

 re in this 

wood heater. Keep all such liquids well away from 
the heater at all   mes.  Storing these or other 

fl

 am-

mable liquids near a wood heater could cause a 

fi

 re.

DO NOT BURN GARBAGE OR FLAMMABLE 
FLUIDS SUCH AS GASOLINE, NAPHTHA OR 
ENGINE OIL.

  

Cord wood is the only fuel approved 

for use in this wood heater.

DO NOT CONNECT THIS UNIT TO A CHIMNEY 
FLUE SERVICING ANOTHER APPLIANCE.

DO NOT CONNECT A WOOD HEATER TO, OR 
USE IN CONJUNCTION WITH, ANY AIR DIS
TRIBUTION DUCTWORK UNLESS SPECIFICAL
LY APPROVED FOR SUCH INSTALLATIONS.

DO NOT OPERATE IN AN EXTREME MANNER 
AS TO OVER FIRE THE WOOD HEATER.

  If any 

part of the wood heater, the chimney, or the chim-
ney connector glows, you are over-

fi

 ring.  If over-

fi

 r-

ing occurs, close all combus  on air controls imme-
diately.  Over-

fi

 ring can cause damage to the wood 

heater and may cause a 

fi

 re.

HOT WHILE IN OPERATION.  KEEP CHILDREN, 
CLOTHING, AND FURNITURE WELL AWAY. 

 

CONTACT MAY CAUSE SKIN BURNS.

  

Observe 

all minimum clearances as listed in this manual. 

 

Maintain a 36” area around the wood heater to be 
kept free of combus  ble materials including furni-
ture and window treatments.  

DO NOT

 allow unat-

tended children in the area of an opera  ng  wood 
heater.

BURN DIRECTLY ON FIRE BRICKS.

  

Do not use 

grates, andirons, or other methods to support fuel. 

FUEL STORAGE.

  

Store bulk cord wood covered in 

a well ven  lated area to ensure that the wood fuel is 
dry as possible.  Do not store wood fuel within stove 
clearances or within the space needed for loading 
stove or ash removal. 

ASH DISPOSAL.

  Ashes should be placed in a steel 

container with a   ght-

fi

    ng lid and moved outdoors 

immediately. The closed container of ashes should be 
placed on a non-combus  ble 

fl

 oor or on the ground, 

well away from all combus  ble materials, pending 

fi

 nal disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 
retained in the closed container un  l all cinders have 
thoroughly cooled. Other waste shall not be placed 
in this container.

CREOSOTE FORMATION & REMOVAL:

  Inspect 

chimney connector and chimney twice monthly, and 
clean if necessary.  Creosote accumula  on in the 
connector pipe, chimney, or 

fl

 ue lining  can create an 

extremely hot 

fi

 re if ignited.

S

 P

G

 S

 I

Содержание 1300

Страница 1: ...pera ng this wood heater If you have ques ons please contact your High Valley Dealer for assistance SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Safety No ce If this wood heater is not properly installed a house fire may result For your safety please carefully read and follow the installa on direc ons Contact the local Building or Fire Official or other Authority Having Jurisdic on AHJ about code r...

Страница 2: ... paint thinners or asphalt products Materials containing asbestos Construc on or demoli on debris Railroad es or pressure treated wood Manure or animal remains Salt water dri wood or other previously salt water saturated materials Unseasoned wood or Paper products cardboard plywood or par cleboard The prohibi on against burning these materials does not prohibit the use of fire starters made from p...

Страница 3: ...hroughout this manual you will find important safety no ces and other informa on may be repeated a number of mes The repe on is inten onal in an effort to reinforce safety instruc ons and to place them in context U S EPA E S T I P 2 T C Page 3 G S I S P Page 4 I P P 5 C P P 6 C R G P 7 C C D P 8 M 1300 S C P 9 P I A P 10 W H I P 11 C C P 12 M H I P 12 P O G P 13 M 1300 F C P 13 O G P 14 O A M P 16 ...

Страница 4: ...r Keep all such liquids well away from the heater at all mes Storing these or other flam mable liquids near a wood heater could cause a fire DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Cord wood is the only fuel approved for use in this wood heater DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT A WOOD HEATER TO OR USE IN CON...

Страница 5: ... sized wood heaters throughout the space to be heated rather than a single large wood heater The number would depend on the size and layout of the home We do not recommend installing your wood heater in an uninsulated basement Much of the heat produced will be lost to the uninsulated walls of the basement NEVER cut holes or vents in a ceiling floor in an a empt to get warm air to rise to the rooms...

Страница 6: ...uare considerably larger than the 6 flue recommended Consider that the cross sec onal area of a 6 flue is 28 sq in Area πr2 or A π32 or A 3 14 X 9 where Pi 3 14 enough for this purpose The cross sec onal area of an 8 round flue is 50 sq in the cross sec onal area of an 8 square masonry flue le is 64 sq in In addi on the masonry construc on tends to cool more quickly with cold outside temperatures ...

Страница 7: ... ceiling supports insulation shields fire stops roof support packages roof flashings chimney caps etc must be installed exactly to the manufacturer s in structions Installation specification and clearances may vary from manufacturer to manufacturer and must be carefully adhered to according to the individual manufacturer s instructions If a new masonry chimney is to be constructed we strongly reco...

Страница 8: ...m combus bles by a minimum of 6 inch 152mm of glass fiber insula on Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge 0 024 inch 0 61mm in thickness Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney sec on Fasteners used to secure chimney sec on shall not penetrate chimney flue liner Solid insulated...

Страница 9: ...5mm w x 1092mm d CN F P Use UL 1618 Type 2 Floor Protector R 1 19 or con nuous non combus ble material equivalent to 1 thickness k 0 42 NOTE Clearances to combus ble materials may be reduced using shielding methods as described in the current edi on of NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances Any reduc on of clearances must be approved by the local Authorit...

Страница 10: ...ct your High Valley Dealer for assistance DO NOT proceed with installa on un l the stove has been inspected and replacement parts obtained P I If your Model 1300 was not assembled before delivery the stove body must be fastened to the pedestal base USE EXTREME CAUTION The wood heater is very heavy At least two strong individuals will be needed to li the stove body onto the pedestal base Personal i...

Страница 11: ...heater Remove the cardboard before ligh ng the first fire in the wood heater The wood heater should be centered on the chimney if possible to allow for the shortest and most direct connec on The wood heater does not necessarily need to be centered on the floor protec on as long as the minimum side pro tec on requirement 8 is met An asymmetrical installa on may provide more usable space to one side...

Страница 12: ...eater must be kept closed at all mes except for star ng and refueling the fire H I U S W P Center the wood heater flue collar in line with the wall thimble if possible All Clearances to combus bles must be maintained Confirm that the factory built wall pass through or masonry thimble meets manufacturer instruc ons and or NFPA 211 See Page 8 Limit the 90 bends to one 1 elbow and the 90 bend where t...

Страница 13: ... of air fed to the fire and thereby regulates the burn rate Pull out to open and push in to close using the spring handle A U S B P B This wood heater is designed and approved for the burning of cord wood fuel only Never burn any type of coal in this heater Burning any type of fuel other than cord wood in this wood heater is against all safety tes ng and will void all warran es D Never use gasolin...

Страница 14: ...er in a fully closed posi on If the fire seems uncontrollable consult your dealer A hand damper installed in the connector pipe will allow for manual control under high dra condi ons CAUTION Before ligh ng your wood heater please read and or re read the safety informa on on pages 2 4 13 and elsewhere throughout this manual Ensure that the wood heater has been installed according to the in struc on...

Страница 15: ...curred Contact your High Valley dealer or local chimney sweep if you are uncertain how to inspect the system for any build up I C C F If your wood heater is op erated properly to maintain clean efficient combus on connected to a good chimney burning good dry wood and inspected as needed a chimney fire should be an un likely occurrence A chimney fire can create a loud rushing sound and perhaps bangin...

Страница 16: ... the wood heater and lay it flat on a well padded work surface Remove the retaining screws from the door and wear ing gloves remove any remaining pieces of ceramic Remove a short sec on of paper backing covering the gasket adhesive from the gasket Center gasket mate rial on the edge of the replacement ceramic and firmly press the gasket onto the edge Con nue around all four sides of the ceramic Tr...

Страница 17: ...ake 9 months for so woods and up to 24 months for hard woods to air dry thoroughly C Clean efficient combus on in your wood heater depends on good quality well seasoned fuel Buying seasoned wood during the burning season is most o en very disappoin ng The best advice is to get green wood in spring and air dry it yourself If you don t cut your own wood find a reputable reliable wood seller So wood sp...

Страница 18: ...an dard 1618 the Standard for Wall Protectors Floor Protec tors and Hearth Extensions was adopted as a standard in 2011 UL 1618 categorizes floor and wall protectors as Type 1 or Type 2 protec on A seemingly minor change in UL 1618 calls for the actual thermal proper es of floor protec on to be specified in R value in place of k value In fact that change makes it one step simpler to calculate ther...

Страница 19: ...of corrosive fuel etc Damage caused by unauthorized modifica on use or repair Damage caused by the use of non High Valley spare parts or accessories Damage caused by lack of regular maintenance and cleaning by the owner as outlined in the Opera ng Instruc ons or due to negligence or carelessness Damage caused by misuse accident neglect or willful abuse of the product damage caused by the use of an...

Страница 20: ... 201 Abbeville SC 29620 www highvalleystoves com High Valley Model 1300 Serial Number High Valley Dealer Date of Purchase Installed by Installa on Date Inspected by Date of Inspec on NOTES OWNER RECORD HL1350 Rev 05 2015 ...

Отзывы: