Powering On the Fixture
To power on the TechnoArc fixture, simply connect it to a 100V-240V AC power source.
Once the TechnoArc fixture is connected to a power source, it automatically begins a homing
procedure to verify that fixture components are functioning.
Shutting Down the Fixture
A DMX controller can shut down the fixture remotely with the Shutdown option in the Control
Channel or you can simply disconnect from power. The TechnoArc fixture automatically shuts
down in the event of DMX data loss longer than five minutes.
Placing Fixture in Road Case
Before shipping a TechnoArc fixture, lock the pan and tilt position so the fixture does not move
during transit.
To lock the fixture:
1. Orient the fixture head for packing in the road case and secure both the pan lock located on
the base and the tilt lock on the yoke arm.
Note: This is the only pan position that locks.
2. Gently move the fixture head and yoke to verify that both pan and tilt positions are locked in
place.
3. Place the TechnoArc fixture in the road case for shipping.
WARNING:
This equipment is designed for connection to a branch circuit having
a maximum overload protection of 20 A.
CAUTION:
Do not power on the fixture until
verifying
that the line cord cap is
suitable for the power source in your location. For more information,
see
Installing a Power Cord Cap
on page 8.
Disengage Pan and Tilt locks before operating the fixture. For more
information, see
Pan and Tilt Locking
on page 7.
Do not unplug motor harnesses while unit is powered.