24
SolaFrame 3000
Frost Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if the Frost movement is not located in the default position after the reset
Gobo Rot 1
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if Gobo Rotating Wheel 1 is not located in the default position after the reset
Gobo Wheel 1
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if Gobo Wheel 1 is not located in the default position after the reset
Gobo Wheel 2
This message displays after the reset of the fixture if any of the following conditions exist:
Pan movement
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the yoke’s magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if the Pan movement is not located in the default position after the reset
Prism Wheel movement
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if the Prism movement is not located in the default position after the reset
Prism_Rot Wheel movement
This message displays after the reset of the fixture if any of the following conditions exist:
•
if the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
•
if the stepper motor is defective or the related IC driver on the main PCB has failed
•
if the Prism_Rot movement is not located in the default position after the reset