background image

5

Front/Rear high pass, using a 2 channel amplifier for mono sub bass

Channels 1/2:

The  combination  of  a  2  and  a  4  channel  amplifier,  utilizing  their  built  in 

- HI PASS: 100 Hz

crossovers, makes it a snap to put together a full system with front and rear 
highs, with mono sub bass.

LOW PASS: N/A

Interconnect cable checklist:

Channels 3/4:

- Using good quality RCA cables, feed the front and rear outputs of a head unit to 

- HI PASS: 

100 Hz

the inputs of the 4 channel amplifier as shown. 

- LOW PASS: 

N/A

- Also connect the 

LINE OUT

 of the 4 channel amplifier to the 

LINE INPUT

 of the 

2 channel amplifier as shown.

2 channel bass amplifier:
- HI PASS (Subsonic filter): 10 Hz to 40 Hz

Mono bass woofer wiring:

- LOW PASS: 80 Hz

Connect the mono speaker positive terminal to the LEFT +, and its negative 
terminal to RIGHT -.

Please  note  that  these  frequency  points  are  suggestions  only.  Refer  to  the 
loudspeaker manufacturer specifications and the section

 “Setting up systems 

Switch setting checklist:

after installation for best performance”

4 channel highs amplifier:
- 1/2CH X-OVER:

 

 HPF

Level control checklist:

- 3/4CH X-OVER:

  

HPF

- Refer to the section 

“Setting up systems after installation for best performance”

2 channel bass amplifier:

Minimum final loudspeaker impedances:

- X-OVER switch:  LPF

- 2 ohm per channel in stereo mode.
- 4 ohm mono bridged.

Crossover frequency control checklist:
- 4 channel highs amplifier:

STEREO

INTERCONNECT

RCA CABLE

ZRX600.4 / ZRX1000.4 / ZRX2000.4 4-CHANNEL AMPLIFIER APPLICATIONS 

POWER INPUT

GND      REM   BA

TT+12V

CH 1/2    SPEAKER OUTPUT    CH 3/4

RIGHT                      LEFT

RIGHT                      LEFT

-          +          -          +           -          +          -          +

BRIDGED

BRIDGED

FUSE

ZEUS

POWER

LEVEL

          BASS EQ    X-OVER          HPF                LPF

CH 3 / 4

CH 1 / 2

LEVEL

          BASS EQ    X-OVER          HPF                LPF               MODE

PROTECT

CH 1 / 2

CH 3 / 4

R

L

LINE OUT

R

L

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FULL

FU
LL

2       3       4

HPF

HPF

LPF

LPF

ZEUS

PO

WER

LEVEL

          BASS EQ    X-OVER          HPF                LPF             MODE

PROTECT

OUTPUT

INPUT

L

R

L

R

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FULL

MONO

HPF

STEREO

LPF

POWER INPUT

GND      REM   BA

TT+12V

SPEAKER OUTPUT

RIGHT                      LEFT

-          +          -          +

BRIDGED

FUSE

REMOTE TURN-ON

CHASSIS GROUND

TO B12v
       VIA FUSE

MONO SPEAKER

or SUBWOOFER

Содержание Zeus ZRX1000.4

Страница 1: ...ZRX500 2 ZRX1200 2 ZRX600 4 ZRX1000 4 ZRX2000 4 ZRX1200 1D ZRX1800 1D ZRX2400 1D ZRX3200 1D...

Страница 2: ...with out the written consent of MAXXSONICS USA Inc ZEUS HIGH PERFORMANCE AMPLIFIERS The Zeus ZRX Series products have been designed to a very high level of performance with features unavailable in any...

Страница 3: ...learance hole in the chassis the same size as the lug hole and use a bolt spring washer and nut to securely fasten the ground lug Use petroleum jelly to coat the bolt lug connection to prevent oxidiza...

Страница 4: ...multipleamplifiersfromonesignal Note that the LOW PASS signal is MONO In the LPF position the HIGH PASS filter acts as a subsonic filter When the LPF mode is selected a 0 to 12dB at 45Hz BASS EQ is al...

Страница 5: ...ver whether stand alone or built into a head Minimumfinalloudspeakerimpedance unit or equalizer Important Do not be tempted to connect the hot or positive outputs from any source together to obtain a...

Страница 6: ...standalone or built into a head unit or equalizer If you only have 1 set of RCA outputs from your headunit you can simply connect those to the inputs for ch TIP If you are using the mono sub bass out...

Страница 7: ...klist afterinstallationforbestperformance 4channelhighsamplifier 1 2CHX OVER HPF Levelcontrolchecklist 3 4CHX OVER HPF Refertothesection Settingupsystemsafterinstallationforbestperformance 2channelbas...

Страница 8: ...Theseampsaremono 1channel amplifiers Minimumfinalloudspeakerimpedance 1 Ohm which have multiple positive and negative connections for ease of wiring The 2 positives arethesameinternallyandthe2negativ...

Страница 9: ...7...

Страница 10: ...ss to 100Hz the amplifier will not play frequencies below 100Hz but will play frequencies from 100Hz to the highest frequency the amplifier is capable of reproducing When in Low Pass Bandpass operatio...

Страница 11: ...undandremoteleadsconnected theamplifiermaybefaulty Systemdoesnotturnon 1 Checkallfuses 2 Checkallconnections 3 Measure the 12 volt and remote turn on voltages at the amplifier terminals If these are n...

Страница 12: ...in the name and address of the authorized reseller Any damage to the product as a result of misuse abuse accident incorrect wiring improper installation alteration of date code or bar code labels revo...

Страница 13: ...11 Biggest POWER systems Moderate POWER systems Smaller POWER systems V3 Products Level 10 Performance 1 Year Warranty V1 Products Level 5 Performance V2 Products Level 7 Performance 6 Month Warranty...

Страница 14: ...PART A113...

Отзывы: