background image

POWER INPUT

GND      REM   BA

TT+12V

CH 1/2    SPEAKER OUTPUT    CH 3/4

RIGHT                      LEFT

RIGHT                      LEFT

-          +          -          +           -          +          -          +

BRIDGED

BRIDGED

FUSE

ZRX600.4 / ZRX1000.4 / ZRX2000.4 4-CHANNEL AMPLIFIER APPLICATIONS 

4 CHANNEL FULL RANGE SYSTEM

2 or 3 CHANNEL SYSTEM

- HI PASS: N/A

Here we show how to use the 4 channel amplifiers as straightforward discrete 4 

- LOW PASS: N/A

channel full range units.

Interconnect cable checklist:

Channels 3/4:

- Connect the four inputs of the amplifier to a Radio/CD with quality RCA cables.

- HI PASS: N/A
- LOW PASS: N/A

Switch setting checklist:
- 1/2CH X-OVER:

  FULL

Level control checklist:

- 3/4CH X-OVER:

  FULL

- Refer to the section 

“Setting up systems after installation for best performance”

Minimum final loudspeaker impedances:

Crossover frequency control checklist:

- 2 ohm per channel.

Channels 1/2:

Switch setting checklist:

Here we show how to use the 4 channel amplifiers as a 3 channel unit by taking 

- 1/2CH X-OVER:

  FULL

advantage of the mono bridging capability of all Hifonics amplifiers.

- 3/4CH X-OVER:

  LPF

The  following  example  shows  how  to  create  a  3  channel  system  by  mono 
bridging channel pair 3 / 4. In order to create a 2 channel system, simply follow 

Crossover frequency control checklist:

the example to also mono bridge channel pair 1 / 2.

Channels 1/2:
- HI PASS: N/A

Interconnect cable checklist:

- LOW PASS: N/A

- Connect the inputs of channel pair 1/2 to a suitable stereo source, e.g. a head 
unit with good quality RCA cables.

Channels 3/4:

- A MONO signal source is required to bridge channel pair 3/4, such as would be 

- HI PASS: N/A

available  from  the  mono  sub  bass  output  of  an  active  crossover,  whether 

- LPF: 11 o’clock

standalone, or built into a head unit or equalizer. If you only have 1 set of RCA 
outputs from your headunit, you can simply connect those to the inputs for ch 

TIP:

 If you are using the mono sub bass output of an active crossover, there is 

1/2 and switch the 

MODE

 to 2ch. The amplifier will auto sum the signal and 

nothing  wrong  with  switching  in  the  low  pass  filter  in  these  amplifiers  for  a 

provide mono output for bridged channels 3/4 once the X-OVER is switched to 

steeper low pass rolloff.

LP/BP. 

Important:

 Do not be tempted to connect the hot, or positive outputs, from any 

Level control checklist:

source together to obtain a mono signal, as this could very well damage the 

- Refer to the section 

“Setting up systems after installation for best performance”

output stage of that source.
- It is necessary to feed the SAME signal to both left and right inputs via a Y-

Minimum final loudspeaker impedances:

adapter RCA cable.

- 2 ohm per channel in stereo mode.

- Connect the mono speaker positive terminal to the LEFT +, and its negative 

- 4 ohm mono bridged.

terminal to RIGHT - as shown.

4

ZEUS

POWER

LEVEL

          BASS EQ    X-OVER     

     HPF                

LPF

CH 3 / 4

CH 1 / 2

LEVEL

          BASS EQ    X-OVER          HPF         

       LPF               MODE

PROTECT

CH 1 / 2

CH 3 / 4

R

L

LINE OUT

R

L

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FULL

FULL

2       3       4

HPF

HPF

LPF

LPF

POWER INPUT

GND      REM   BA

TT+12V

CH 1/2    SPEAKER OUTPUT    CH 3/4

RIGHT                      LEFT

RIGHT                      LEFT

-          +          -          +           -          +          -          +

BRIDGED

BRIDGED

FUSE

ZEUS

POWER

LEVEL

          BASS EQ    X-OVER          HPF                LPF

CH 3 / 4

CH 1 / 2

LEVEL

          BASS EQ    X-OVER          HPF                LPF               MODE

PROTECT

CH 1 / 2

CH 3 / 4

R

L

LINE OUT

R

L

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FU
LL

FU
LL

2       3       4

HPF

HPF

LPF

LPF

STEREO LINE INPUT

MONO LINE INPUT

(Unless using procedure
listed above for 3ch)

Содержание Zeus ZRX1000.4

Страница 1: ...ZRX500 2 ZRX1200 2 ZRX600 4 ZRX1000 4 ZRX2000 4 ZRX1200 1D ZRX1800 1D ZRX2400 1D ZRX3200 1D...

Страница 2: ...with out the written consent of MAXXSONICS USA Inc ZEUS HIGH PERFORMANCE AMPLIFIERS The Zeus ZRX Series products have been designed to a very high level of performance with features unavailable in any...

Страница 3: ...learance hole in the chassis the same size as the lug hole and use a bolt spring washer and nut to securely fasten the ground lug Use petroleum jelly to coat the bolt lug connection to prevent oxidiza...

Страница 4: ...multipleamplifiersfromonesignal Note that the LOW PASS signal is MONO In the LPF position the HIGH PASS filter acts as a subsonic filter When the LPF mode is selected a 0 to 12dB at 45Hz BASS EQ is al...

Страница 5: ...ver whether stand alone or built into a head Minimumfinalloudspeakerimpedance unit or equalizer Important Do not be tempted to connect the hot or positive outputs from any source together to obtain a...

Страница 6: ...standalone or built into a head unit or equalizer If you only have 1 set of RCA outputs from your headunit you can simply connect those to the inputs for ch TIP If you are using the mono sub bass out...

Страница 7: ...klist afterinstallationforbestperformance 4channelhighsamplifier 1 2CHX OVER HPF Levelcontrolchecklist 3 4CHX OVER HPF Refertothesection Settingupsystemsafterinstallationforbestperformance 2channelbas...

Страница 8: ...Theseampsaremono 1channel amplifiers Minimumfinalloudspeakerimpedance 1 Ohm which have multiple positive and negative connections for ease of wiring The 2 positives arethesameinternallyandthe2negativ...

Страница 9: ...7...

Страница 10: ...ss to 100Hz the amplifier will not play frequencies below 100Hz but will play frequencies from 100Hz to the highest frequency the amplifier is capable of reproducing When in Low Pass Bandpass operatio...

Страница 11: ...undandremoteleadsconnected theamplifiermaybefaulty Systemdoesnotturnon 1 Checkallfuses 2 Checkallconnections 3 Measure the 12 volt and remote turn on voltages at the amplifier terminals If these are n...

Страница 12: ...in the name and address of the authorized reseller Any damage to the product as a result of misuse abuse accident incorrect wiring improper installation alteration of date code or bar code labels revo...

Страница 13: ...11 Biggest POWER systems Moderate POWER systems Smaller POWER systems V3 Products Level 10 Performance 1 Year Warranty V1 Products Level 5 Performance V2 Products Level 7 Performance 6 Month Warranty...

Страница 14: ...PART A113...

Отзывы: