![HID Vertx CS V100 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/hid/vertx-cs-v100/vertx-cs-v100_quick-installation-manual_2129460006.webp)
VertX V100 (CS) Quick Installation Guide
August 2005
Page 6 of 9
2005 © HID Corporation. All rights reserved.
3.
RS-485 Connections
: Connect the V100 to the V1000 through the RS-485 cable. See the V1000
Quick Install Guide for further information.
CAUTION: The V1000 RS-485 Ports 1 & 2 (P1) are a common bus and therefore cannot have
duplicate Interface Addresses assigned. The same is true of the V1000 RS-485, Ports 3 & 4 (P4).
For example, Interface Address 0 (factory default) cannot be assigned to both Ports 1 & 2 (P1).
4.
Interface Address
– Set the interface address by turning the
Address
dial. Ensure that
the V100 Interface Address is documented in the Hardware Installation Worksheet (found
in the back of the HID VertX V1000 Quick Install guide).
5.
Output Connections –
All Output connections are used for general
purpose controls. The following table shows where the various outputs are
located. Pin numbers shown use the convention “NO/C/NC”.
For example, Output 1, V2000: P3 Pin1 is NO (Normally open) and Pin 2 is
C (Common) and Pin 3 is NC (Normally closed).
Note:
Relay contacts are rated for 2Amps @ 30VDC.
Output
number
V2000
V1000
V100
V200
V300
1
P3 Pins 1/2/3
Strike (lock)
Relay 1
P14 Pins
2/3/4
P3 Pins 1/2/3
Strike (lock)
Relay 1
P3 Pins 2/3/4
P1 Pins 1/2/3
2
P3 Pins 4/5/6
Aux Relay 1
P11 Pins
6/5/4
P3 Pins 4/5/6
Aux Relay 1
P6 Pins 3/2/1
P1 Pins 4/5/6
3
P6 Pins 6/5/4
Strike (lock)
Relay 2
P6 Pins 6/5/4
Strike (lock)
Relay 2
P1 Pins 7/8/9
4
P6 Pins 3/2/1
Aux Relay 2
P6 Pins 3/2/1
Aux Relay 2
P2 Pins 1/2/3