Страница 1: ...Reader User Guide Technology Solutions UK Ltd Suite A Loughborough Technology Centre Epinal Way Loughborough Leicestershire LE11 3GE United Kingdom Tel 44 0 1509 238248 Fax 44 0 1509 220020 Email enq...

Страница 2: ...oduct names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All software is provided strictly on an as is basis All softwa...

Страница 3: ...d orientation 7 7 Versions of the 1060 8 8 Software 9 8 1 Driver description 9 8 2 Driver installation 9 8 3 Reader Test 10 9 Peripheral compatibility 13 11 Troubleshooting and Maintenance 14 11 1 Mai...

Страница 4: ...host mobile computer The mechanical design of the unit allows it to be quickly and easily removed alternatively two screws can be fitted to make the installation semi permanent The 1060 Smartcard rea...

Страница 5: ...1 Technology Solutions UK Ltd 3 Attaching to an MC70 75 75A Figure 2 Attaching to an MC70 75 75A 1 Align the slots on the side of the Mobile Computer with the guides on the fixing clips of the 1060 Sm...

Страница 6: ...60 Smartcard Reader User Guide V1 0 pdf www tsl com Copyright 2021 Technology Solutions UK Ltd 4 Detaching from an MC70 75 75A Figure 3 Detaching from an MC70 75 75A 1 Remove the latch locking screws...

Страница 7: ...ich indicates the operating status of the 1060 Smartcard reader The LED lights green when the driver is correctly loaded and the Mobile Computer is powered up The LED lights orange whenever there is c...

Страница 8: ...at least 500 000 insertions The updated 1060 is identified by a B in the serial number printed on the back of the reader as shown in Figure 5 Figure 5 Identifying the 1060 version The two versions ar...

Страница 9: ...As a minimum the software listed in the table below should be installed for each of the different Mobile Computers and Smartcard readers Mobile computer Software required for original 1060 Software re...

Страница 10: ...AB 1060B MC75 Driver install for the latest 1060B Smartcard reader name appears as OMNIKEY CardMan 3111 0 1060B Smartcard Driver CAB 1060B MC75A Also requires SPR21116 CAB for OEM OS versions 3 41 000...

Страница 11: ...ting to the file using File Explorer and tapping on it If TestResMan launches and then immediately closes the driver has not deployed successfully Consult the Troubleshooting Section 11 2 Assuming Tes...

Страница 12: ...ations and services at any time without notice Page 12 of 22 1060 Smartcard Reader User Guide V1 0 pdf www tsl com Copyright 2021 Technology Solutions UK Ltd Figure 7 TestResMan ATR Tap Disconnect and...

Страница 13: ...is not available because it is used exclusively by the 1060 ActiveSync connections to the Mobile Computer can be established over USB Power is passed directly through the 1060 to the Mobile Computer a...

Страница 14: ...Remove and re insert the Mobile Computer from the 1060 Smartcard Reader ensuring it is firmly seated The driver is not installed Check that the correct driver and support application has been install...

Страница 15: ...e MC70 from the 1060 Smartcard Reader ensuring it is firmly seated ActiveSync cannot connect to the Mobile Computer ActiveSync is not correctly configured on the PC or the Mobile Computer Detach the S...

Страница 16: ...les Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause...

Страница 17: ...Typically 30mA excluding current drawn by smartcard User indication Green LED On whilst driver is loaded and Mobile Computer is active Orange LED Flashes with communication to a smartcard Connection...

Страница 18: ...Technology Solutions UK Ltd Sealing Internal components conformal coated Electrostatic discharge 15kV air discharge 8kV contact discharge Construction RoHS compliant Regulatory EMC EN 55022 2010 EN 5...

Страница 19: ...ect pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures For vehicle installation and use An air bag inflates with great f...

Страница 20: ...of the same becoming apparent D Product Service Products may be serviced or manufactured with parts components or subassemblies that originate from returned products and that have been tested as meet...

Страница 21: ...CTS SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY The stated express warranties are in lieu of all obligations or liabilities on the part of TSL for damages including but not l...

Страница 22: ...K Ltd Suite A Loughborough Technology Centre Epinal Way Loughborough Leicestershire LE11 3GE United Kingdom Telephone 44 1509 238248 Fax 44 1509 214144 Email enquiries tsl com Website www tsl com Abou...