Wire Connections

1

2

3

4

5

6

7

8

9

10

+DC

Ground

Data0/

Data

Data1/

Clock

Shield

 Ground

Green

LED

Red

 LED

Beeper

Hold

Card

 Present

Red

Black

Green

White

Drain

Orange

Brown

Yellow

Blue

---

+DC, Ground, Shield Ground, Data0 and Data1 are required for Wiegand Operation

+DC, Ground, Shield Ground, Data, Clock, and Card Present are required for Clock and Data Operation.
All others (Green LED, Red LED, Beeper and  Hold are optional.

Notes: 1) When using a separate power supply for the ThinLineII, the power supply and Host should have
a common ground (voltage reference). 2) If the Host is controlling the beeper, Hold, or the LEDs are
configured for the dual  LED mode, additional conductors will be required.  The recommended cables are
Alpha 1295C, 1296C, 1297C, 1298C and 1299C that are five, six, seven, eight and nine conductors
respectively. Larger wire gauges are acceptable. The wire is to be stranded with an overall shield, either
foil or braided. 3) The Cable shield should be connected to the Shield Ground on Reader TB1- 5, and left
floating at the Panel or power supply end of the cable. This configuration is the best for shielding the
reader cable from external interference and reducing the likelihood of the Reader causing interference.

Product Configuration/Ordering Options

      539X  B  X   X XX - XXXX Y

Customer Custom Artwork or Firmware Number -  1 through 9, A
through Z

Customer Custom Number

Configuration Options - (00 standard)

Standard Hardware Options - P = Pigtail, T = Terminal strip,
*Other
Color - B = Beige, W = White, K = Black

Current Revision Letter - changes for upgrades

Model Number 5395 = ThinLine II Wiegand,

                                                 5368 = ThinLine II Clock and Data

Ø

 

Standard Wiegand Part Number = 5395WN00 is a ThinLine II, White, Potted and 10
conductor, 15” Pigtail.

Ø

 

Standard Clock and Data Part Number = 5398WN00 is a ThinLine II, White, Potted and 10
conductor, 15” Pigtail.

Product Specifications

Read Distance

Ø

 

Overall Operating Limits (12VDC - minimum)

4.00 inches (10.2 cm)

Ø

 

Non-Metallic Mounting (12VDC - typical)

5.0 inches (12.7 cm)

Ø

 

Mounted on Metal (12VDC - typical)

5.0 inches (12.7 cm)

Ø

 

Overall Operating Limits (5VDC - minimum)

2.5 inches (6.3 cm)

Ø

 

Non-Metallic Mounting (5VDC - typical)

3.0 inches (7.6 cm)

Ø

 

Mounted on Metal (5VDC -  typical)

3.0 inches (7.6 cm)