____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690
Web page, E-mail - www.prox.com MIFARE
Wiegand Reader Installation Manual 6074-901 REV 2 2 of 5
Product Specifications
Read Distance
¾
Overall Operating Limits (10VDC - minimum)
1.0-1.5 inches (2.5-3.8 cm)
¾
Non-Metallic Mounting (12VDC - typical)
1.0-1.5 inches (2.5-3.8 cm)
¾
Mounted on Metal (12VDC - typical)
1.0-2.5 inches (2.5-3.8 cm)
Environmental Characteristics
¾
Operating Temperature Range
-30
o
C to 65
o
C (-22
o
F to 150
o
F)
¾
Storage Temperature Range
-40
o
C to 85
o
C (-40
o
F to 185
o
F)
¾
Operating Humidity Range
5% to 95% non-condensing
¾
Operating Vibration Limit
.04 g
2
/Hz 20-2000Hz
¾
Operating Shock Limit
30g, 11mS, Half Sine
¾
Potting Material
UL Recognized Filled Polyurethane
¾
Enclosure Material
UL Recognized Lexan Polycarbonate
¾
Potted Weight
8.2oz (228grms)
Power Requirements
¾
Power supply
Linear type recommended
¾
Operating Voltage Range (+DC)
10.0VDC -14.0VDC
¾
Absolute Maximum (+DC non-operating)
14.0VDC
¾
Maximum Average Current at 12V
60mA
¾
Transient Protection (all terminals)
8,000 volts
¾
Reverse Voltage Protection
-15V on all I/O and -35 for power lines
¾
Input Voltage (maximum data-0/1 lines)
15.0VDC
¾
Input Voltage (maximum interface lines)
15.0VDC
Operating Parameters
¾
Excitation Frequency
13.56MHz
¾
Read and Report Speed (26 bit Wiegand Card)
200mS (1K card) + output data
¾
Maximum Cable Distance to Host
500 feet (152 meters)
¾
LED Type Bi-colored Red/Green
¾
LED Operation (host control of red/green)
<
.5V on LED control line
¾
Beeper Operation (host control)
<
.5V on beeper line
¾
Beeper Control (default)
Beeper enabled
FCC Compliance Statement:
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
NOTE: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES. ALL LOCAL, STATE
AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.