Hibon NX 12 Скачать руководство пользователя страница 9

80446693 Rev. B 

EN-9

EN

2. TECHNICAL DATA

2.5 Lubrication data

On standard applications, you can use an oil which complies 
with the ‘standard use’ specification given in Table 6. You must 
use an oil which complies with the ‘special use’ specification in 
Table 6:

If you use the blower with an acoustic enclosure.

If you use the blower in ambient temperatures of 0 ° C  
(32 ° F) or below.

If you use the blower with a power input that exceeds 2 / 3 
of the maximum power input (see Table 3).

Parameter

Standard use

Special use

Density (at 15 °C, 
59 °F) 

0.89

0.86

Mean pour point 

21 °C (70 °F) 

45 °C (113 °F) 

Mean flash point 

224 °C (435 °F) 

260 °C (500 °F) 

Viscosity: at 20 °C  
(68 °F) 

8.09 x 10¯4 m2 s¯1  
(809 cSt) 

6.04 x 10¯4 m2 s¯1  
(640 cSt) 

at 40 °C (104 °F) 

2.2 x 10¯4 m2 s¯1  
(220 cSt) 

2.18 x 10¯4 m2 s¯1  
(218 cSt) 

at 100 °C (212 °F) 

1.8 x 10¯5 m2 s¯1  
(18 cSt) 

2.7 x 10¯5 m2 s¯1  
(27 cSt) 

Mean viscosity 
index 

93

149

Recommended oil  Hibon Lub

Contact factory

Table 6 – Lubricating oil specifications

Drive end cover 

NX 2 

NX 3

NX 5

NX 8

NX 12

NX 18

NX 26

0,83 litres

0,83 litres

0,83 litres

1,50 litres

1,50 litres

2,41 litres

2,41 litres

0,22 US gal

0,22 US gal

0,22 US gal

0,40 US gal

0,40 US gal

0,64 US gal

0,64 US gal

Non-drive end cover

1,12 litres

1,12 litres

1,12 litres

2,10 litres

2,10 litres

3,84 litres

3,84 litres

0.30 US gal 

0.30 US gal

0.30 US gal

0.55 US gal

0.55 US gal

1.01 US gal

1.01 US gal

Table 7 – Left and Right Hand blower oil capacities

Drive end cover 

NX 2 

NX 3

NX 5

NX 8

NX 12

NX 18

NX 26

0,5 litres

0,5 litres

0,5 litres

0,9 litres

0,9 litres

1,45 litres

1,45 litres

0,13 US gal

0,13 US gal

0,13 US gal

0,24 US gal

0,24 US gal

0,38 US gal

0,38 US gal

Non-drive end cover

0,75 litres

0,75 litres

0,75 litres

1,30 litres

1,30 litres

2,3 litres

2,3 litres

0,20 US gal

0,20 US gal

0,20 US gal

0,34 US gal

0,34 US gal

0,61 US gal

0,61 US gal

Table 8 – Top and Bottom Shaft blower oil capacities

2.6 Materials of construction

Head Plates and End 
Covers

EN GJL 200 grey cast iron

Casings

EN GJL 200 grey cast iron 
(NX 2, NX 3, NX 5, NX 8, NX 12)

EN GJL 250 grey cast iron  
(NX 18, NX 26)

Rotors

EN GJS 400-15 spheroidal graphite 
cast iron

Bearings

100Cr6 steel

Piston rings

Cast iron

Piston rings holder

C 45E Steel

Gaskets

Klingerit® C4430

O-rings

Nitrile

Table 9 – Construction materials data

www.fraserwoods.ca

Содержание NX 12

Страница 1: ...EN Instalaci n operaci n y mantenimiento ES Installation fonctionnement et entretien FR Installation Betrieb und Wartung DE Installazione funzionamento e manutenzione IT Authorized Hibon Distributor...

Страница 2: ...chinery must not be put in service until the final machinery into which is to be incorporated has been declared in conformity with the provisions of this directive Cette presque machine ne doit pas tr...

Страница 3: ...ported by mounting feet 17 3 5 Fill the blower with oil 17 3 6 Fit the drive transmission 17 3 7 Check the direction of rotation 18 3 8 Commissioning the blower 18 4 OPERATION 19 4 1 General operation...

Страница 4: ...ed in the correct phase relation by timing gears The timing gears and the bearings on the rotors and drive shaft are lubricated by oil in the drive end cover 4 and non drive end cover 12 The blowers a...

Страница 5: ...10 Nondrive end oil drain plug behind blower 11 Oil level sight glass non drive head plate 12 Nondrive end cover 13a Identification and rating plate vertical position 13b Identification and rating pl...

Страница 6: ...differential pressures across the blower that is the differential pressures between the blower inlet and outlet The r p m r min 1 rotation speeds specified in Tables 4 and 5 are provided for informati...

Страница 7: ...18 17 1 595 20 8 574 24 5 568 25 7 500 576 12 2 4900 870 9 7 824 15 786 21 761 25 5 739 30 500 759 15 3 NX 5 1570 m3 h 2000 493 6 447 9 5 409 13 4 384 16 2 400 416 7 6 3000 797 8 9 743 14 3 699 20 671...

Страница 8: ...48 25 7 4800 790 19 2 752 30 7 720 43 0 699 52 1 14 9 715 31 9 NX 8 1149 CFM 1500 326 9 8 293 15 266 21 1 11 8 274 11 7 2300 561 15 1 528 23 1 500 32 3 480 40 469 44 6 14 9 470 22 3 3100 796 20 3 762...

Страница 9: ...litres 1 50 litres 2 41 litres 2 41 litres 0 22 US gal 0 22 US gal 0 22 US gal 0 40 US gal 0 40 US gal 0 64 US gal 0 64 US gal Non drive end cover 1 12 litres 1 12 litres 1 12 litres 2 10 litres 2 10...

Страница 10: ...T O R I O N T A T O R I O N T A T O R I O N T A T O R I O N T A T O R I O N T A T O R Inlet gas stream Note Refer to Table 10 for the item numbers of blowers with the configurations shown in the figur...

Страница 11: ...01250 F0151001111 47001268 B Top Anticlockwise F015100120 47001276 F0151001201 47001284 C Top Clockwise F015100121 47001292 F0151001211 47001300 D Left Anticlockwise F015150100 47001318 F0151501001 47...

Страница 12: ...51 13 0 51 13 0 51 15 0 59 15 0 59 h 152 5 6 00 152 5 6 00 152 5 6 00 185 7 28 185 7 28 225 8 86 225 8 86 L 485 19 09 555 21 85 650 25 59 671 26 42 791 31 14 848 33 39 993 2 39 10 L1 245 9 65 305 12...

Страница 13: ...80446693 Rev B EN 13 EN 2 TECHNICAL DATA r B D EA GC Y X T Z H E h R S A a L1 L F 4 x P V W DN G F Detail F n number of holes Figure 4 Top and Bottom Shaft blower dimensions www fraserwoods ca...

Страница 14: ...224 5 8 84 224 5 8 84 L 485 19 09 555 21 85 650 25 59 671 26 42 791 31 14 848 33 39 993 2 39 10 L1 245 9 65 305 12 01 356 14 02 385 15 16 454 17 87 441 17 36 559 22 01 T 45 1 77 45 1 77 45 1 77 51 5 2...

Страница 15: ...more than 200 mg m3 1 37 x 10 5 lb ft3 of dust Incorporate suitable filters to prevent the ingress of solids into the blower The temperature of the gases which enter the blower must not exceed the te...

Страница 16: ...alled directly in your system You must ensure that your system pipelines can support the blower Prepare locate and connect blower as described in Section 3 4 2 Supported by mounting feet prepare locat...

Страница 17: ...end cover 4 with oil refer to Section 5 5 1 3 Fill the non drive end cover 12 with oil refer to Section 5 5 2 3 6 Fit the drive transmission WARNING You must fit suitable guards to protect people fro...

Страница 18: ...ate Perform the direction of rotation check from Step 2 again to ensure that the blower now rotates in the correct direction 6 If you have removed the guard over the drive coupling or belt as in Step...

Страница 19: ...ed to the inlet when the blower is operating Prevent accidental contact with the hot blower and do not place flammable materials on the blower During operation the temperature of external parts of the...

Страница 20: ...you maintain the blower use Ingersoll Rand spares refer to Section 7 3 Operation Frequency Refer to Section Check the oil levels Inspect the system installation Change the oil Overhaul the blower Week...

Страница 21: ...ls in the blower are correct If you do not the blower will probably be damaged during operation or its performance may be affected WARNING You must take care about the oil temperature Please wait at l...

Страница 22: ...e the rotors unbalanced Clean the rotors and rotor housing then check the rotor clearances and adjust as necessary The blower overheats Is the inlet filter blocked Clean or replace the filter Is the d...

Страница 23: ...cation If necessary redesign your system to comply with the capabilities of the blower or fit a different blower which provides the necessary performance Is the inlet filter blocked Clean or replace t...

Страница 24: ...suitable protective oil see Table 16 use the method in Section 5 3 3 Turn the blower drive shaft by hand through three or four revolutions to turn the blower and prevent seizure 4 Spray a suitable pro...

Страница 25: ...Rand engineers to support on site maintenance service or repair of your equipment For more information about service options contact your nearest Service Centre or other Ingersoll Rand company 7 3 Spa...

Отзывы: