Replacing the Chamber Block

HP-

150

/

200

REPLACING THE CHAMBER BLOCK

CAUTION

! 

Be sure to unplug the pump unit.

 

Replace the diaphragms and the valves with new ones at least once a year to one and 
a half year regularly in order to maintain their initial performance.

 

For  chamber  block  replacement,  be  sure  to  change  both  chamber  blocks  at  the  same 
time.

 

The  rod  employs  powerful  permanent  magnets.  Therefore,  be  sure  to  remove  your 
watch and any other precision machines before operation as they may be affected by 
the strong magnetic force.

 

Do not put the actuating rod close to a magnetic card, magnetic disk or other magnetic 
media as the data may be destroyed.

STEP

1

STEP

1

REMOVAL OF THE CHAMBER BLOCKS

To remove the upper housing. 

(Refer to 

REMOVING UPPER HOUSING

Remove the sound absorber.

STEP

2

STEP

2

Pull out the L-tube from the casing block.

STEP

3

STEP

3

Remove  the  4  screws  holding  the  chamber  block 

and the casing block. 

(4 screws on each side)

Содержание hp-150

Страница 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Страница 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Страница 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Страница 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Страница 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Страница 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...

Страница 7: ...the hexagonal nuts by the nut driver 8mm wrench Loosen the screw holding the frame stay and remove it Pull out the electromagnet from the pump body CAUTION Be sure to unplug the pump unit When perform...

Страница 8: ...he wires to the terminals Solder the wires to the terminals The wire requires a soldered connection Mount new electromagnet in the unit Fix frame stay temporarily Do not tighten screw of frame stay an...

Отзывы: