The flow control features a concentrate flow control valve, a recycle flow control valve, and a 

pressure gauge.

The proper adjustment of these valves is critical to the operation of the RO machine. The 

concentrate  valve  determines  the  amount  of  rejected  water  leaving  the  machine,  and 
creates the operating pressure shown on the pressure gauge. The recycle valve returns 
unused reject flow back into the inlet stream to the RO pump. It is important to balance the 
operating pressure and the respective flows of these valves to ensure that your machine is 
operating correctly. The pump has a fixed amount of flow produced, and the valves are the 
control devices to distribute this fixed amount of flow produced. The pressure gauge is an 
indicator of applied membrane pressure at the flows set by the valves.

4.8

Turn on the machine; allow the machine to operate for one minute to purge the air from the 

machine. As you are operating, be sure to watch the pressure gauge on the flow control 
center. The machine is designed to operate at maximum 225 psi.

NOTE : Do not allow the pressure to exceed 200 psi. If the pressure exceeds 200 psi, open 

the concentrate flow valve until the pressure gauge shows 200 psi or less.

As the machine purges the air and fills with water, the pressure will gradually increase. You 

should see water flowing from the permeate and concentrate outlets. If you do not see flow 
from these points, turn the machine off and return to Section 4.1

 

CAUTION :

NEVER  ALLOW  THE  MACHINE  TO  OPERATE  WITHOUT 

ADEQUATE  FEEDWATER  PRESSURE,  AS  THIS  MAY  CAUSE 
SERIOUS MACHINE DAMAGE.

The concentrate flow control valve has a drilled orifice to ensure a predetermined amount of 

flow and pressure in the closed position. This orifice is sized to operate the machine at 50% 
recovery.

5.0

FLUSHING AND CLEANING

5.1 

Flushing

The  machine  should  be  flushed  weekly  to  remove  sediment  from  the  surface  of  the 

membrane . To flush the unit:

5.1.1

Open the concentrate valve until the pressure gauge reads the pressure designated 
on the nameplate. Normally this will be 50 psig (3.5 bar).

NOTE :

If pressure will not drop to specified pressure during flushing, the valve 
must be cleaned.

5.1.2

Allow the machine to run at its designated pressure for 10 to 20 minutes.

5.1.3

Close the concentrate valve to its previous position and check to be sure a proper 

concentrate flow rate is going to the drain.

5.1.4

The machine is ready to operate.

Содержание RO-300 DLX

Страница 1: ...OPERATION AND MAINTENANCE MANUAL RO 300 DLX HI TECH SWEET WATER TECHNOLOGIES PVT LTD H I T E C H S W E E T W A T E R T E C H N O L O G I E S P V T L T D ...

Страница 2: ...te can be increased by opening the concentrate valve slightly However it is suggested that the customer purchase a replacement valve steam from Hi Tech which will allow the valve to be closed and still give an adequate concentrate flow rate NOTE In order to maintain warranty an operating log must be maintained Copies can be sent to Hi Tech for review Extra log sheets are available upon request 1 2...

Страница 3: ...0 50 1 is supplied and is wired with an4 foot cord A 3 prong plug is provided for use in a standard household outlet receptacle An appropriate plug must be wired to the cord provided for use in a standard household outlet receptacle for 220 50 1 units All field wiring must comply with applicable national and local codes WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK THE INCOMING POWER SUPPLY MUST IN...

Страница 4: ... only 3 0 OPERATION SPECIFICATIONS 3 1 Osmonics Table 1 Membrane Operating Parameters Salt Rejection Membrane Monovalent Ions 96 Polyvalent Ions 98 Suspended Matter Rejection 99 Bacteria Rejection 99 Pyrogen Rejection 99 Organic Rejection 99 1 150 MV pH Range 5 5 10 0 Continuous Free Chlorine Short term exposure to 0 2 mg L 2 Continuous exposure less than 0 1 mg L Slit Density Index 5 Iron Concent...

Страница 5: ...t should be used 4 0 START UP 4 1 Recheck the function and integrity of your pretreatment equipment Ensure that your water softener and activated carbon filters iron filters When applicable have been leak checked backwashed and thoroughly rinsed for service before starting up your RO unit 4 2 Attach feedwater hose to the inlet of the machine 4 3 Check for leaks at all connection points 4 4 Turn on...

Страница 6: ...essure exceeds 200 psi open the concentrate flow valve until the pressure gauge shows 200 psi or less As the machine purges the air and fills with water the pressure will gradually increase You should see water flowing from the permeate and concentrate outlets If you do not see flow from these points turn the machine off and return to Section 4 1 CAUTION NEVER ALLOW THE MACHINE TO OPERATE WITHOUT ...

Страница 7: ...re plumbed The pressure switch is designed to shut the RO machine down in the event of a low pressure condition The pressure switch is designed to shut the machine off when the feedwater pressure is below 40 psi The machine will restart when the pressure exceeds 40 psi 6 3 Permeate and Concentrate Flow Meters The optional flow meters are panel mounted and pre plumbed These flow meters are the rota...

Страница 8: ...e voltage check the fuses and circuit breakers Contact your Hi Tech distributor or Hi Tech for replacement or repair of pump if requires See above Re install the membranes correctly Re install the membrane correctly being careful not to r o l l t h e c o n c e n t ra t e seal membranes with damaged concentrate seals may be returned for repair Clean the membranes Remove and clean the valve steam an...

Страница 9: ...e s replacement Storage tank float switch has cut power to machine Thermal overload of motor Pump motor failure Clean the membrane Replace the O rings and check the sealing surfaces Replace damaged parts Replace the membranes as needed The storage tank may be full The switch control may require adjustment Allow the machine to cool Check the amp draw of the motor Check the fuses or circuit breakers...

Страница 10: ...After obtaining clean water make the coke position to service mode again Follow the above operation twice thrice in a week NOTE ALWAYS OFF INLET FEEDWATER SUPPLY BEFORE CHANGING THE POSITION OF COKE FROM SERVICE MODE TO BACKWASH MODE PROCESS OF ACTIVATED CARBON FILTER ACTIVATED CARBON FILTER ACF To remove color Odor and Smell from the water To remove Oil Grease from the water To control the BOD CO...

Отзывы: