2.1

Plumbing

A certain amount of water must be used to continuously rinse the RO membranes and carry 
the concentrated, rejected materials away from the membrane. The concentrate outlet is 
located on the outlet side of the concentrate valve. Approximately 6 feet of 3/8 inch nylon 
tubing should be connected to the concentrate outlet and run to an open drain. The tubing 
must be unobstructed. There is no restriction as to the length of the tubing.

The  RO  permeate  outlet  is  located  on  the  end  cap(s)  of  the  membrane  housings.  The 
permeate outlet is ½ inch tube. The permeate should be transported to the point of use 
through  high-quality  nylon  or  stainless  steel  tubing.  PVC  pipe  or  other  FDA-acceptable 
materials.

0

Maximum recommended inlet temperature is 40 C. 

2.3

Electrical

A ¼-HP, ½-HP or ¾-HP 220/50/1 is supplied, and is wired with an4-foot cord. A 3-prong 
plug is provided for use in a standard household outlet receptacle.

An appropriate plug must be wired to the cord provided for use in a standard household 
outlet receptacle for 220/50/1 units. All field wiring must comply with applicable national and 
local codes.

WARNING :

TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK,  THE  INCOMING 

POWER  SUPPLY  MUST  INCLUDE  A  PROTECTIVE  EARTH 
GROUND.

2.4

Pump

The pumps used on this product line are rotary vane pumps. These pumps must be run on 

filtered water only. When the pumps require servicing, simply remove the pump head with a 
screwdriver and return it to Hi-Tech The head will be reconditioned and returned at a nominal 
charge. It is advisable to purchase a new pump to use while the old pump is being evaluated 
for reconditioning. At times, purchasing a new pump is less expensive than reconditioning 
the old pump.

CAUTION :

NEVER LET THE PUMP RUN DRY, AS THIS WILL CAUSE SERIOUS 
DAMAGE TO THE MACHINE.

Содержание RO-300 DLX

Страница 1: ...OPERATION AND MAINTENANCE MANUAL RO 300 DLX HI TECH SWEET WATER TECHNOLOGIES PVT LTD H I T E C H S W E E T W A T E R T E C H N O L O G I E S P V T L T D ...

Страница 2: ...te can be increased by opening the concentrate valve slightly However it is suggested that the customer purchase a replacement valve steam from Hi Tech which will allow the valve to be closed and still give an adequate concentrate flow rate NOTE In order to maintain warranty an operating log must be maintained Copies can be sent to Hi Tech for review Extra log sheets are available upon request 1 2...

Страница 3: ...0 50 1 is supplied and is wired with an4 foot cord A 3 prong plug is provided for use in a standard household outlet receptacle An appropriate plug must be wired to the cord provided for use in a standard household outlet receptacle for 220 50 1 units All field wiring must comply with applicable national and local codes WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK THE INCOMING POWER SUPPLY MUST IN...

Страница 4: ... only 3 0 OPERATION SPECIFICATIONS 3 1 Osmonics Table 1 Membrane Operating Parameters Salt Rejection Membrane Monovalent Ions 96 Polyvalent Ions 98 Suspended Matter Rejection 99 Bacteria Rejection 99 Pyrogen Rejection 99 Organic Rejection 99 1 150 MV pH Range 5 5 10 0 Continuous Free Chlorine Short term exposure to 0 2 mg L 2 Continuous exposure less than 0 1 mg L Slit Density Index 5 Iron Concent...

Страница 5: ...t should be used 4 0 START UP 4 1 Recheck the function and integrity of your pretreatment equipment Ensure that your water softener and activated carbon filters iron filters When applicable have been leak checked backwashed and thoroughly rinsed for service before starting up your RO unit 4 2 Attach feedwater hose to the inlet of the machine 4 3 Check for leaks at all connection points 4 4 Turn on...

Страница 6: ...essure exceeds 200 psi open the concentrate flow valve until the pressure gauge shows 200 psi or less As the machine purges the air and fills with water the pressure will gradually increase You should see water flowing from the permeate and concentrate outlets If you do not see flow from these points turn the machine off and return to Section 4 1 CAUTION NEVER ALLOW THE MACHINE TO OPERATE WITHOUT ...

Страница 7: ...re plumbed The pressure switch is designed to shut the RO machine down in the event of a low pressure condition The pressure switch is designed to shut the machine off when the feedwater pressure is below 40 psi The machine will restart when the pressure exceeds 40 psi 6 3 Permeate and Concentrate Flow Meters The optional flow meters are panel mounted and pre plumbed These flow meters are the rota...

Страница 8: ...e voltage check the fuses and circuit breakers Contact your Hi Tech distributor or Hi Tech for replacement or repair of pump if requires See above Re install the membranes correctly Re install the membrane correctly being careful not to r o l l t h e c o n c e n t ra t e seal membranes with damaged concentrate seals may be returned for repair Clean the membranes Remove and clean the valve steam an...

Страница 9: ...e s replacement Storage tank float switch has cut power to machine Thermal overload of motor Pump motor failure Clean the membrane Replace the O rings and check the sealing surfaces Replace damaged parts Replace the membranes as needed The storage tank may be full The switch control may require adjustment Allow the machine to cool Check the amp draw of the motor Check the fuses or circuit breakers...

Страница 10: ...After obtaining clean water make the coke position to service mode again Follow the above operation twice thrice in a week NOTE ALWAYS OFF INLET FEEDWATER SUPPLY BEFORE CHANGING THE POSITION OF COKE FROM SERVICE MODE TO BACKWASH MODE PROCESS OF ACTIVATED CARBON FILTER ACTIVATED CARBON FILTER ACF To remove color Odor and Smell from the water To remove Oil Grease from the water To control the BOD CO...

Отзывы: