5

Pin

Symbol

Name

Function

1

OUT

Target status

output

Human presence detected: output high level

No human presence: output low level

2

UART_Tx

Serial port Tx

Serial port Tx pin

3

UART_Rx

Serial port Rx

Serial port Rx pin

4

GND

Power ground

Power ground

5

VCC

Power input

Power input

5V (acceptable 5V ~ 12V voltage power supply)

Table 1 Pin Definition Table

5.Usage and Configuration

5.1 Typical Application Circuit

The LD2410 module directly outputs the detected target state through an IO pin (high level

when there is someone, low level when there is no one), and can also output the detection result data

through the serial port according to the specified protocol. It includes target status and distance

auxiliary information, etc., which can be used flexibly by users according to specific application

scenarios.

The module IO level is 3.3V. The default baud rate of the serial port is 256000, 1 stop bit, no

parity bit.

5.2 The Role of Configuration Parameters

The user can modify the configuration parameters of the module through the serial port of the

LD2410 to adapt to different application requirements, and the configuration content will not be lost

when the power is turned off.

The configurable parameters include the following:

Farthest detection distance

If the farthest detectable distance has been set, only human objects that appear within the

farthest distance will be detected and the result will be output.

If set in units of distance gates, each distance gate is 0.75m.

Including the farthest door for motion detection and the farthest door for static detection, the setting

range is 1- 8m. If the farthest door is set to 2, only if there is a human body within 1.5m will it be

effectively detected and output the result.

Sensitivity

Only when the detected target energy value (range: 0~100) is greater than the sensitivity value

will it be determined that the target exists, otherwise it will be ignored.

The sensitivity value can be set from 0 to 100. The sensitivity of each range gate can be

independently set, so that the detection in different distance ranges can be precisely adjusted, local

accurate detection or filtering of interference sources in specific areas.

In addition, if the sensitivity of a certain distance gate is set to 100, the effect of not recognizing

Содержание HLK-LD2410

Страница 1: ...Shenzhen Hi Link Electronic co Ltd HLK LD2410 Human Presence Sensing Module User Manual Version V1 02 Date 2022 6 8 Copyright Shenzhen Hi Link Electronics Co Ltd...

Страница 2: ...esign Principles 11 7 3 Common materials 12 8 Revision History 12 9 Technical Support and Contact 13 Chart Index Table 1 Pin Definition Table 5 Table 2 Performance and Electrical Parameters Table 10 T...

Страница 3: ...ry information such as the distance of the target can be calculated This product is mainly used in indoor scenes to sense whether there is a moving or micro moving human body in the area and output th...

Страница 4: ...LD2410 human body sensing module adopts 24GHz millimeter wave radar sensor technology Compared with other solutions it has obvious advantages in human body sensing applications 1 In addition to being...

Страница 5: ...hting equipment in public places various sensor lights bulb lights etc Human sensitive wake up of advertising screen and other equipment Automatically turn on when people come and automatically hibern...

Страница 6: ...Description 4 1 Dimension Figure 4 Physical Map of the Module Figure 5 Module Dimensions Size 7mmx35mm 5 pin holes are reserved in the hardware the factory default does not match the pins The pin hole...

Страница 7: ...the module through the serial port of the LD2410 to adapt to different application requirements and the configuration content will not be lost when the power is turned off The configurable parameters...

Страница 8: ...a PC configuration tool is provided The user can use this tool software to connect the serial port of the module read and configure the parameters of the module and also receive the detection result...

Страница 9: ...Shenzhen Hi Link ELectronics Co Ltd User Manual HLK LD2410 7 5 4 Mounting Method and Sensing Range Figure 7 Schematic Diagram of Ceiling mounted Installation...

Страница 10: ...410 8 Distance unit meters Angle unit degrees Figure 8 Schematic Diagram of the Detection Range the ceiling height is 3 meters Radar Wall 6 Height 1 5 2 meters Distance unit meters Angle unit degrees...

Страница 11: ...a and the strong reflectors will cause interference to the radar antenna When installing on the wall external interference factors such as air conditioners and electric fans on the top of the room nee...

Страница 12: ...ication standards Operating Voltage 5V Can accept 5V 12V voltage power supply Average operating current 80 mA Modulation FMCW Interface A GPIO IO level 3 3V A UART Target application Human presence se...

Страница 13: ...e Design Principles Structural shape of the radome The surface is smooth and flat and the thickness is uniform Such as plane or spherical surface can not be uneven If there is a surface coating it mus...

Страница 14: ...e wavelength For example 12 4 or 18 6mm is recommended for 24 125GHz Error control 1 2mm Radome thickness D Recommended half wavelength error control 20 If the thickness requirement of half wavelength...

Страница 15: ...2410 13 9 Technical Support and Contact Shenzhen Hi Link Electronic Co Ltd Add 301 Building 1 1970 Science and Technology Park Minzhi Community Minzhi Street Longhua District Shenzhen Tel 0755 2315265...

Отзывы: