Hi-Force HTWP Series Скачать руководство пользователя страница 5

Operating Instruction Manual: 

OM-HTWP-ELECTRIC-01 

Serial Numbers: 

From: BP5141  

 

 

 

NEVER

 use a hammer and punch to unseat a coupler check valve that is under pressure. Doing so 

could result in the sudden, uncontrolled release of hydraulic oil at high pressure, which could cause 
significant injury or death. 

 

 

NEVER 

attempt to solve, or clean-up leaks in the system while the system is pressurised.

  

  Immediately replace any worn or damaged parts using genuine Hi-Force parts only. 

 

DO NOT

 use any hydraulic equipment if you are under the influence of alcohol, drugs or medication. 

Lack of attention whilst operating high-pressure hydraulic tools can result in personal injury or death. 

 
 

Failure to observe and obey the following safety precautions could result 
in  property  damage,  equipment  damage  or  minor / moderate  personal 
injury; 

 

NEVER 

lift, carry or move any hydraulic components by the hose or hoses connected to them.

 

 

Avoid  damaging  hydraulic  hoses. 

ALWAYS

  route  hoses  to  ensure  that  they  are  free  from  sharp 

bends and kinks. Using a sharply bent or kinked hose will result in severe back-pressure, which can 
lead to hose failure.

 

 

NEVER 

use a coupler/s to lift, carry or position a tool. 

 

Servicing of hydraulic equipment must only be undertaken by a qualified technician.

 

 

DO NOT 

drop or place heavy objects on a hydraulic hose, as this may cause 

internal  damage,  which  could  result  in  rupture  of  the  pressurised  hose.  A 
ruptured hose could cause significant damage to components and possible 
severe injury to personal operating nearby.

 

 

DO  NOT

  let  familiarity  gained  with  any  hydraulic  tools  allow  you  to  become  complacent. 

Complacency with any tooling can result in a lack of discipline toward working guidelines and safety 
principles. 

 

DO  NOT

  remove  any  labels  from  the  product.  Replace  any  damaged  or  unreadable  labels 

immediately. 

  Avoid loose clothing and jewellery that could get caught in moving parts, tie back long hair. 

 

2.5 Hydraulic Pump Specific Safety Precautions 

Failure to observe and obey the following safety precautions could result 
in property damage, serious personal injury or death; 

 

NEVER

 exceed the maximum rated pressure of any hydraulic equipment. Hi-Force manufactures 

its HTWP Electric hydraulic pumps to operate at a maximum working pressure of 700 bar (10,000 
psi).  

DO NOT

 connect hydraulic torque equipment with a lower pressure capacity rating to any Hi-Force 

pump of this model series.   

Содержание HTWP Series

Страница 1: ...are available on the Hi Force website The right is reserved to make changes at any time without notice This Original instructions document assumes that the operator carrying out any operation with th...

Страница 2: ...corporation Conformity 6 4 0 Specifications 7 4 0 Component Identification 8 5 0 Installation Setup 10 6 0 Operation 16 7 0 Maintenance and Storage 19 9 0 System Components Accessories 19 10 0 Pressur...

Страница 3: ...ct If in doubt on the correct use of any Hi Force equipment contact your nearest Hi Force office or distributor Only qualified personnel should be allowed to operate hydraulic equipment If an operator...

Страница 4: ...ome cases death Should this incident occur seek out medical attention immediately Seek medical attention immediately if a hydraulic injection injury no matter how minor occurs The system operating pre...

Страница 5: ...n lead to hose failure NEVER use a coupler s to lift carry or position a tool Servicing of hydraulic equipment must only be undertaken by a qualified technician DO NOT drop or place heavy objects on a...

Страница 6: ...e the area release the pressure and ensure the hydraulic relief valve on the pump is fully open ALWAYS disconnect the pump from the power supply when carrying out maintenance or adjustments except pre...

Страница 7: ...rade Temperature range Degrees Celsius From To ISO15 23 44 ISO46 2 73 Pump Specification Refer to the identification plate on the pump for model identification HTWP Torque Wrench Pumps Electric Driven...

Страница 8: ...nent Identification 1 Start Stop relay switch 5 Oil level Temperature gauge 2 Electric Motor 6 Drain plug 3 Adjustable pressure relief valve 7 Tool Advance Coupler 700 bar maximum 4 Oil reservoir 8 To...

Страница 9: ...OM HTWP ELECTRIC 01 Serial Numbers From BP5141 9 9 Oil pressure gauge 12 Tool Advance button 10 Oil filler breather cap 13 Motor control box 11 Pendant control 14 Roll frame Figure 4 2 Component Ident...

Страница 10: ...the Reservoir with Oil IMPORTANT The HTWP Electric Range of pumps uses ISO46 Grade Hydraulic Oil IMPORTANT Only add oil to the reservoir when the attached tool is fully retracted Failure to do so may...

Страница 11: ...ectly so that the male high pressure advance coupler 7 is connected to the advance port on the tool Failure to do so may result in leakage tool damage or personal injury 5 3 1 Connections See figure 5...

Страница 12: ...se to the male advance coupler 7 on the pump Connect the male coupler on the black hose to the female retract coupler 8 on the pump Connect the free end of the red hose to the advance port on the torq...

Страница 13: ...air must be removed from the system The following procedure must be carried out with a torque wrench connected to the pump but NOT fitted on a bolt Hi Force uses superior quick connect couplers on its...

Страница 14: ...ssure 700 bar is reached The pressure can be reduced by turning the knob anti clockwise The pressure setting can be locked at the desired value by tightening the wing nut under the adjusting knob cloc...

Страница 15: ...gin to advance Continue until the gauge reads approximately 100 bar With the pressure holding steady around 100 bar perform a visual inspection of the tool s hoses and couplers for any signs of oil le...

Страница 16: ...of the required working pressure s that must be applied to the Torque Wrench s You have read and fully understood the torqueing sequence and procedure You have performed the relevant risk assessment s...

Страница 17: ...re 4 1 3 Press and hold down the advance button 12 on the pendant The tool will advance and stop at its maximum stroke this is correct 4 While holding the pump in advance mode slowly turn the relief v...

Страница 18: ...ue tool operator s the pump MUST ONLY be operated once all torque wrench tool operators have indicated it is safe to do so 1 Prepare the pump for operation as per section 6 1 2 Set the required pressu...

Страница 19: ...isconnect from the power supply remove the oil drain plug 6 on the bottom of the reservoir and drain the used oil into a suitable container Replace the drain plug 6 and refill with high grade ISO46 hy...

Страница 20: ...5 132 6 480 6962 489 5 140 2031 142 8 490 7107 499 7 150 2176 153 0 500 7252 509 9 160 2321 163 2 510 7397 520 1 170 2466 173 4 520 7542 530 3 180 2611 183 5 530 7687 540 5 190 2756 193 7 540 7832 550...

Страница 21: ...ier gauge extension cord ii Turn off excess electrical loads 3 Pump struggles to build pressure or maintain pressure under load a Oil level too low Check unit for visible leaks Add oil as per section...

Страница 22: ...s Contact your local Hi Force office distributor c Oil level too low Check unit for visible leaks Add oil as per section 5 2 d Air in the hydraulic system Bleed air from the system See section 5 7 e T...

Страница 23: ...1 23 UK Head Office Hi Force Limited Prospect Way Daventry Northamptonshire NN11 8PL United Kingdom Tel 44 1327 301000 Fax 44 1327 706555 Email daventry hi force com GLOBAL BRAND LOCAL SERVICE www hi...