6.3. Pump Operation
Hi-force recommends that operation of the pump/wrench combination be a minimum 2
person job, one to operate the pump and one to operate the wrench. An additional
operator will be required for each addition wrench connected to the pump.
To reduce the likelihood of a finger / hand trapping accident, at least one of the
operators
MUST
be trained in the safe usage of the equipment and a clear system of
communication
MUST
be established.
To ensure the safety of the torque tool operator/s, the pump
MUST ONLY
be operated
once all torque wrench / tool operators have indicated it is safe to do so.
1. Prepare the pump for operation as per section 6.1.
2. Set the required pressure (torque) as per section 6.2.
3. Press the green start button (1) to start the pump.
4. Press
and hold the ‘Advance’ (12) button to advance the tool. (See torque wrench operating
instructions for more details about the wrench operation)
5.
When the wrench stops advancing, release the ‘Advance’ button. The tool will automatically retract
ready for the next operation.
6. Turn the pump off by pressing the red
‘Stop’ button on the motor control box (
13
).
Good Practice:
Set the relief valve (3) to the fully open position (wound anti-clockwise) after use.
7. Disconnect from the power supply.