Hi-Force HEP1 Скачать руководство пользователя страница 8

 

INSTRUCTION MANUAL – Electric Driven Pump Series HEP:  

Model Series: HEP1, HEP103, HEP2, HEP3, HEP5 

 

Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom 

Tel: +44(0) 1327 301000:  Fax: +44(0) 1327 706555: Website: www.hi-force.com 

turn the control knob clockwise. To 
decrease the relief valve setting turn the 
control knob anticlockwise. Leaving the 
pump running for extended periods with 
the relief valve operating will cause the oil 
to overheat. 
 
3. Ensure that the oil level does not fall 
below the minimum level as shown by the 
lower indicator (7) 
 
OPERATION OF PUMPS WITH SOLENOID 
VALVES 
1. Turn switch to ‘on’ position (8) 
2. Depress ‘advance’ button on pendant 
to advance cylinder. (Cylinder remains in 
the load holding position when button 
released). 
 
3. Depress ‘retract’ button to retract 
cylinder. 
 
OPERATION OF PUMPS WITH SOLENOID 
VALVE AND AUTO RETRACT FUNCTION 
1. Turn switch to ‘on’ position (8) 
 
2. Depress ‘advance’ button on pendant 
to advance cylinder. (Cylinder will not 
remain in the load- holding position when 
button is released). 
 
3. Release ‘advance’ button to retract 
cylinder. 
 
MAINTENANCE 
To ensure reliable operation and long life it 
is important to carry out maintenance at 
set intervals. You should always follow 
these simple rules: 
 
•Inspect the pump for damage after each 
use. 
•Change the oil every 500 working hours 
using Hi-Force HFO46 oil. 
•Have the pump serviced regularly by a 
Hi-Force authorised repair centre. 

 

 
Always make sure that: 
• The pump is cleaned before returning to 
storage. 
• Lubricate moving parts. 

• Check that there are no external 
hydraulic oil leaks. 
• Make sure the pump has not suffered 
any external damage, as a result of 
impacts, etc. 
 
 
 
 
 

 

 
 
 

 
 
 
 

 

 

 
 

 

 

Содержание HEP1

Страница 1: ...ing damage is not covered by warranty If shipping damage is found notify the carrier immediately and refrain from putting the product into service The carrier is responsible for repair and replacement costs resulting from damage in transit shipment 2 0 Safety Precautions Read and follow all the instructions and safety warnings carefully prior to use of the equipment Failure to do so could result i...

Страница 2: ...nspect all hoses on a regular basis for damage and wear Do Not use hoses that are frayed abraded or leaking Never lift pull or carry any hydraulic pump or components by the hose or hoses connected to them Do not handle a pressurized hydraulic hose Oil escaping under pressure from a ruptured hose can penetrate the skin and lead to a serious medical emergency and in certain cases death Should this i...

Страница 3: ...essure again Maintenance To ensure reliable operation and long life it is important to carry out maintenance at set intervals You should always follow these simple rules Use only Hi Force HFO32 oil to keep the reservoir topped up Ensure that connected cylinders are fully retracted before checking oil level otherwise reservoir may become pressurised and damaged The Oil should be changed completely ...

Страница 4: ...correct power supply is used for your model of Hi Force pump Either 110V or 220 240V 50 60Hz single phase Check the oil level before use Retract the cylinder fully beforehand to do so Only use Hi Force Hydraulic oil Operation HEP103341 and HEP103342 1 Close release valve lever by turning clockwise 45 See Figure 2 2 Press ON button to advance cylinder Release the button and the cylinder will hold i...

Страница 5: ... handle to the right hand side position 45 max Press ON button to retract the cylinder Flow to port B port A returns flow to the reservoir See Figure 3 Figure 3 Circuit Diagram HEP103441 HEP103442 HEP103441LS HEP103442LS 1 Press ON button to run the motor and to advance the cylinder Flow to port A Port B returns flow to reservoir The motor stops with button ON released 2 Press OFF button to run th...

Страница 6: ...lve 11 Hydraulic service connections one or two ports depending on valve type 12 Remote control pendant fitted to models with solenoid valves only Model No Hydraulic Connection HEP207111 HEP207112 HEP207114 HEP207121 HEP207122 HEP207124 HEP310121 HEP310122 HEP310124 HEP310141 HEP310142 HEP310144 HEP517122 HEP517142 HEP517144 HEP517162 HEP517164 No control valve Pump P and Tank T connections for si...

Страница 7: ...ves are remotely mounted ensure these are adjusted such that pressure will not build up during the starting operation See table on page 1 7 Ensure switch is set to off 8 Connect motor to required power source 8 Check the direction of the motor rotation by turning the starter switch 8 to the ON position then to the off position whilst doing this observe the motor fan The motor should run in a clock...

Страница 8: ...sition when button released 3 Depress retract button to retract cylinder OPERATION OF PUMPS WITH SOLENOID VALVE AND AUTO RETRACT FUNCTION 1 Turn switch to on position 8 2 Depress advance button on pendant to advance cylinder Cylinder will not remain in the load holding position when button is released 3 Release advance button to retract cylinder MAINTENANCE To ensure reliable operation and long li...

Отзывы: