INSTRUCTION MANUAL – Electric Driven Pump Series HEP:
Model Series: HEP1, HEP103, HEP2, HEP3, HEP5
Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom
Tel: +44(0) 1327 301000: Fax: +44(0) 1327 706555: Website: www.hi-force.com
Instructions for HEP2, HEP3 &HEP3 series two
stage electric Driven Pumps
Motor size and supply options:
HEP2 Series: Motor 1.5kW
Supply: 110/115v single phase 50Hz or 60Hz
220/240v single phase 50Hz or 60 Hz
380/440v three phase 50/60Hz
HEP3 & HEP5 Series: Motor 2.2kW
Supply: 110/115v single phase 50Hz or 60Hz
220/240v single phase 50Hz or 60 Hz
380/440v three phase 50/60Hz
Common models and typical uses are
given below:-
Note: Models with a suffix ‘S’ (e.g.
HEP207414S) have a 3 or 4 way solenoid
operated valve with a remote control
pendant.
Note: Models with a suffix ‘S-AR’ (e.g.
HEP310322S-AR) have a 3 way solenoid
operated valve with an auto retract
function.
IDENTIFICATION OF COMPONENTS
Refer to figure 1 and 2.
1. Hydraulic oil drain plug.
2. Hydraulic directional control valve – if
fitted (type will vary)
3. Roll frame (optional).
4. Motor.
5. Oil filler breather cap.
6. Tank.
7. Hydraulic oil level gauge.
8. On/off switches
9. Electrical control box.
10. Adjustable pressure relief valve.
11. Hydraulic service connections,(one or
two ports, depending on valve type)
12. Remote control pendant (fitted to
models with solenoid valves only).
Model No:
Hydraulic Connection
HEP207111
HEP207112
HEP207114
HEP207121
HEP207122
HEP207124
HEP310121
HEP310122
HEP310124
HEP310141
HEP310142
HEP310144
HEP517122
HEP517142
HEP517144
HEP517162
HEP517164
No control valve, Pump (P)
and Tank (T) connections for
single and double acting
cylinders, controlled by
remote mounted valves.
HEP207211
HEP207212
HEP207214
HEP207221
HEP207222
HEP207224
HEP310221
HEP310222
HEP310224
HEP310241
HEP310242
HEP310244
HEP517242
HEP517244
HEP517262
HEP517264
2 way valve for operating
single acting cylinders and
tools requiring advance and
retract, but no "hold"
function. E.g. Crimpers and
cutters
HEP207311
HEP207312
HEP207314
HEP207321
HEP207322
HEP207324
HEP310321
HEP310322
HEP310324
HEP310341
HEP310342
HEP310344
HEP517342
HEP517344
HEP517362
HEP517364
3 way valve for operating
single acting cylinders
requiring advance, retract
and central load hold
position. E.g. Simple lifting
operations
HEP207411
HEP207412
HEP207414
HEP207421
HEP207422
HEP207424
HEP310421
HEP310422
HEP310424
HEP310441
HEP310442
HEP310444
HEP517442
HEP517444
HEP517462
HEP517464
4 way valve for operating double
acting cylinders, requiring
advance, retract and central load
hold position.E.g. lifting and
positioning where more control
is required.