Description: 
Hi-Force HEP series pumps are designed to 
operate high pressure hydraulic cylinders 
and tools with a maximum working 
pressure of 700 bar. These instructions 
cover all HEP series models. Refer to 
nameplate on pump for the full model 
identification. 
     

Please read this instruction booklet 
carefully before operating the product 
and keep in a safe place for future 
reference.  
It is the responsibility of the purchaser to 
ensure that operators are properly trained 
in the safe use of this equipment and have 
access to HI-Force Operating and Safety 
Instructions
.  
No modification and/or additions may be 
made to this equipment without the 
written permission of the manufacturer.  
It is expected that the product is used by 
competent technical personnel who have 
been properly trained to use hydraulic 
lifting equipment 
 
NOTE: Spare parts sheets for these 
products are available from the Hi-Force 
website at: 

www.hi-force.com

 

or from your local regional Hi-Force Sales 
office or authorized local Hi-Force 
distributor

 

1.0

 

Inspection of the product upon receipt: 

On receipt of the product, visually inspect 
the item for any evidence of shipping 

damage. Please note shipping damage is 
not covered by warranty. If shipping 
damage is found notify the carrier 
immediately and refrain from putting the 
product into service. The carrier is 
responsible for repair and replacement 
costs resulting from damage in transit 
shipment. 
 
2.0

 

Safety Precautions: 

 

Read  and  follow  all  the  instructions  and 
safety warnings carefully prior to use of the 
equipment. Failure to do so could result in 
equipment  damage  or  failure  of  the 
equipment  or  personal  injury.  Hi-Force  will 
not be held responsible for any damage to 
the  equipment  or  personal  injury  resulting 
from  unsafe  use  of  the  product,  lack  of 
maintenance  or  incorrect  operation.  If  in 
doubt on the correct usage of any Hi-Force 
equipment, contact your nearest Hi-Force 
office or distributor. If the operator has not 
been  trained  on  high  pressure  hydraulic 
equipment  and  its  safe  use  consult  your 
local  Hi-Force  sales  office  who  can  offer 
you training courses for operators. 

 

 

All  operators  should  ensure  that  all 
necessary  personal  protective  equipment 
as specified by their employer is worn when 
operating any hydraulic equipment. Safety 
shoes,  safety  glasses/  visor  and  protective 
gloves  should  be  worn  at  all  times.  All 
relevant  risk  assessments  should  be 
completed prior to use of the equipment. 

 

Warning: All ancillary equipment to 
be used with these ranges of 

hydraulic manual pumps MUST be rated 
for use at the same operating pressure as 
the pump model to be used:- 
HEP12 series – 700bar (10,000psi) 
HEP103 series – 700 bar (10,000psi) 
HEP2, HEP3 &HEP5 series–700 bar(10,000psi) 

 

Sufficient time should be allocated to 
planning your hydraulic system. 

Содержание HEP1

Страница 1: ...ing damage is not covered by warranty If shipping damage is found notify the carrier immediately and refrain from putting the product into service The carrier is responsible for repair and replacement costs resulting from damage in transit shipment 2 0 Safety Precautions Read and follow all the instructions and safety warnings carefully prior to use of the equipment Failure to do so could result i...

Страница 2: ...nspect all hoses on a regular basis for damage and wear Do Not use hoses that are frayed abraded or leaking Never lift pull or carry any hydraulic pump or components by the hose or hoses connected to them Do not handle a pressurized hydraulic hose Oil escaping under pressure from a ruptured hose can penetrate the skin and lead to a serious medical emergency and in certain cases death Should this i...

Страница 3: ...essure again Maintenance To ensure reliable operation and long life it is important to carry out maintenance at set intervals You should always follow these simple rules Use only Hi Force HFO32 oil to keep the reservoir topped up Ensure that connected cylinders are fully retracted before checking oil level otherwise reservoir may become pressurised and damaged The Oil should be changed completely ...

Страница 4: ...correct power supply is used for your model of Hi Force pump Either 110V or 220 240V 50 60Hz single phase Check the oil level before use Retract the cylinder fully beforehand to do so Only use Hi Force Hydraulic oil Operation HEP103341 and HEP103342 1 Close release valve lever by turning clockwise 45 See Figure 2 2 Press ON button to advance cylinder Release the button and the cylinder will hold i...

Страница 5: ... handle to the right hand side position 45 max Press ON button to retract the cylinder Flow to port B port A returns flow to the reservoir See Figure 3 Figure 3 Circuit Diagram HEP103441 HEP103442 HEP103441LS HEP103442LS 1 Press ON button to run the motor and to advance the cylinder Flow to port A Port B returns flow to reservoir The motor stops with button ON released 2 Press OFF button to run th...

Страница 6: ...lve 11 Hydraulic service connections one or two ports depending on valve type 12 Remote control pendant fitted to models with solenoid valves only Model No Hydraulic Connection HEP207111 HEP207112 HEP207114 HEP207121 HEP207122 HEP207124 HEP310121 HEP310122 HEP310124 HEP310141 HEP310142 HEP310144 HEP517122 HEP517142 HEP517144 HEP517162 HEP517164 No control valve Pump P and Tank T connections for si...

Страница 7: ...ves are remotely mounted ensure these are adjusted such that pressure will not build up during the starting operation See table on page 1 7 Ensure switch is set to off 8 Connect motor to required power source 8 Check the direction of the motor rotation by turning the starter switch 8 to the ON position then to the off position whilst doing this observe the motor fan The motor should run in a clock...

Страница 8: ...sition when button released 3 Depress retract button to retract cylinder OPERATION OF PUMPS WITH SOLENOID VALVE AND AUTO RETRACT FUNCTION 1 Turn switch to on position 8 2 Depress advance button on pendant to advance cylinder Cylinder will not remain in the load holding position when button is released 3 Release advance button to retract cylinder MAINTENANCE To ensure reliable operation and long li...