TDS1343
1010
BC63
Press the die release buttons situated on opposite sides of the tool and slide each
die half into place ensuring that a matching pair is used.
FITTING A BATTERY PACK
To fit the battery, Remove the protective cover from the terminals (retain for future
use) push firmly into the housing on the base of the tool handle until it clicks into
place. To remove battery depress battery latch button and pull battery away from the
handle as shown in the diagrams. Charge the battery before use by means of
charger CU110, CU220 or CU1114. Spare battery packs are available from HI-
Force. Order part number BP144.
OPERATION.
Pressing the trigger will advance the piston and close the dies. Pressing the release
button will retract the piston and open the dies.
Correctly position the crimper over the connector to be crimped. Press and hold the
trigger and the dies will close and crimp the connector to the cable.
When the connector is fully crimped to the cable the dies will be fully closed and no
further movement takes place. The pressure relief valve on the tool will then operate
and the motor will be heard to speed up. Release the trigger. Press the release
button and the dies will retract ready for next use. Note, keep the release button
depressed until the dies have fully retracted.
The LED battery indicator gives the status of the battery and shows when it is
necessary to recharge the battery.
Red yellow and green light – battery condition good.
Red and yellow lights – battery running low
Red – Battery exhausted – Recharge required. Or replace with spare battery