3
1.0 Specifications
Max air consumption:
6 m³ (212scfm) at 7 bar.
A
minimum supply pipe bore of ½” diameter is required to allow the pump to operate correctly.
Fluid inlet port:
1” BSP (All models)
Outlet Port:
ATDP63
= ½” NPT
ATDP125 = ½” NPT
ATDP216 = 1.1/8” -12 UNF
Pump operating temperatures:
-20c to +50c
Noise level:
An average A-Weighted sound pressure level of 75dB was measured for undefined workspaces, as per
Directive 2006/42/EC Section 1.7.4.2 (u).
Recommended Fluids:
•
De-ironised / De-minerelised water.
•
Water Glycol
•
Hydraulic oil (see chart below)
Hi-Force tools use 2 grades of hydraulic oil, dependant on the tool.
ISO Hydraulic oil grade
Temperature range Degrees Celcius
From:
To:
ISO15
-23
44
ISO46
-2
73
IMPORTANT:
If in doubt about the suitability of the operating fluid you intend to use, please consult
your nearest Hi-Force office or distributor. Use of unsuitable operating fluids
WILL
void your
warranty.