  If the air supply is turned to the OFF position the hydraulic pressure generated will hold on the pumps 

integral check valves (in small volume systems the hydraulic pressure may fall slightly and then stop 
whilst the check valve balls reseat, this is normal).  

The pump will continuously stroke if the circuit is open (flushing mode). Close the air start/stop valve to stop 
the pump at any point, if required.  

 

7) Once the test is completed to release hydraulic system pressure:  

  Turn the air on/off valve to the off position  

  Turn the air pressure- regulating valve anticlockwise until it fully is wound out.  

 

Slowly

 open the pressure release valve and fluid will return via the drain hose to drain until zero 

pressure is indicated on the pump hydraulic pressure gauge.  

It is possible to pre-set the pump so it stalls automatically at the desired pressure. This can be done by 
plugging  the  pressure  outlet  port  and  operating  the  pump.  Adjust  the  air  pressure  regulator  gradually 
upwards such that the pump stalls at the correct pressure. Release the pressure by opening the pressure 
release  valve.  Close  the  pressure release  valve once  more to  check  the  set  pressure.  Provided that  no 
adjustments are made the pump will repeat this set pressure when connected to a pressure vessel.

 

 

 

9.0 Maintenance and Storage 

Carry  out  basic  maintenance  on  a regular  basis  to  keep  the  system  operating  in  a trouble-free manner. 
Maintenance intervals are determined by the frequency of use of the system and the operating conditions 
on site. 

  Keep the unit clean. Use a damp cloth to avoid any static build up. 

  Silicone  type  grease  is  prone  to  stiffening  when  not  in  use,  at  a  minimum  the  grease  should  be 

changed after a 6 month idle period and every 12 months in a scheduled routine service interval at 
a minimum. 

 

ALWAYS

 keep the unit upright in storage. 

IMPORTANT: 

ALWAYS

 dispose of used fluids in a responsible manner, in accordance with local 

regulations. 

 

 

 

 

 

Содержание ATDP125

Страница 1: ...the Hi Force website Hi Force reserves the right to make changes to this document at any time without notice This Original instructions document assumes that the operator carrying out any operation w...

Страница 2: ...5 4 3 Electrical Safety ATEX Page 5 4 4 General precautions Page 5 4 5 ATDP Specific safety precautions Page 7 5 0 Declaration of conformity Page 7 6 0 General description Page 8 7 0 Component identif...

Страница 3: ...ghted sound pressure level of 75dB was measured for undefined workspaces as per Directive 2006 42 EC Section 1 7 4 2 u Recommended Fluids De ironised De minerelised water Water Glycol Hydraulic oil se...

Страница 4: ...ent costs resulting from damage that occurred in transit 4 0 Safety Precautions 4 1 Introduction Read and follow all the instructions and safety warnings carefully before handling installation or use...

Страница 5: ...at all times All relevant risk assessments should be completed before the use of the equipment Keep hydraulic equipment away from open flames and direct heat NEVER handle a pressurised hydraulic hose...

Страница 6: ...t they are free from sharp bends and kinks Using a sharply bent or kinked hose will result in severe back pressure which can lead to hose failure NEVER use a coupler s to lift carry or position a tool...

Страница 7: ...its delivered condition Your warranty may be invalidated and it could lead to serious personal injury NEVER exceed the maximum rated capacity of any hydraulic system component Keep hands and feet away...

Страница 8: ...otor automatically shifts reversing the pump direction hence delivery flow is relatively smooth with only a small interruption in flow dwell as the pump air pistons change direction The units consist...

Страница 9: ...Instruction Manual OM ATDP 01 From Serial Number All 9 upon the air pressure applied i e Pump ratio 216 1 1psig air drive pressure applied can generate 216psig hydraulic pressure 7 0 Component Identi...

Страница 10: ...essure rated air hose and fittings for this purpose these components must be rated at a higher working pressure than the maximum supply air pressure that can be applied to the power pack 1 2 bore air...

Страница 11: ...sure generated can be viewed on the hydraulic pressure gauge The maximum pressure achievable at various air pressures can be seen in the Hi Force catalogue ATDP page under the heading Max output press...

Страница 12: ...desired pressure This can be done by plugging the pressure outlet port and operating the pump Adjust the air pressure regulator gradually upwards such that the pump stalls at the correct pressure Rele...

Страница 13: ...ized or worn Contact your local Hi Force office distributor 2 Motor stalls before full operating pressure is reached a Insufficient air supply Check supply lines and pressure 3 Pump struggles to build...

Страница 14: ...truction Manual OM ATDP 01 From Serial Number All 14 UK Head Office Hi Force Limited Prospect Way Daventry Northamptonshire NN11 8PL United Kingdom Tel 44 1327 301000 Fax 44 1327 706555 Email daventry...

Страница 15: ...land B V Numansdorp Netherlands Tel 31 85 902 8111 Email holland hi force com Hi Force Saudi Dammam Saudi Arabia Tel 966 13 802 1338 Email saudi hi force com Hi Force Hydraulics Abu Dhabi United Arab...

Отзывы: