background image

HHB CDR850 PLUS

This  supplement is intended to provide the user with the additional information  required  to operate  the
CDR850PLUS and  is to be used in  conjunction  with the  standard  Operating Instructions  of the  CDR850.

Thank  you for purchasing the CDR850 PLUS. The PLUS provides the user with the ability to lock the
machine’s master clock to a variety of external 44.1KHz clock sources including wordclock. In addition, a
balanced digital output  is featured,  allowing the greater cable lengths necessary in large installations
without the inherent  signal degradation.

EXTERNAL     

SYNCHRONISATION

In today’s digital studio environment,  it is becoming more and more  important  to be able to
lock/synchronise  all digital equipment to a common sampling frequency or house clock.  The effects  of
‘unlocked’ equipment  are all too noticeable as signal degradation, crackles  and pops as machines  ‘clock’
at different rates.

The CDR850  PLUS can be set (via a 4-way dipswitch on the rear panel) to ‘lock’ to a number of different
clock sources as indicated in the following  table:

Playback Clock Source

X = either ON or OFF

ON = Switch down

Any combination  of  switch position that does not appear in the above table will result in the 850 PLUS
reverting to INTERNAL.

System Example:

CDR850 PLUS

DIGITAL

MIXING DESK

WORD CLOCK @ 44.1KHZ

SW1

SW2

SW3

SW4

Clock Source

ON

X

X

X

INTERNAL

OFF

ON

OFF

OFF

WORD CLOCK

OFF

OFF

OFF

ON

AES/EBU

OFF

OFF

ON

ON

SPDIF COAX

OFF

OFF

OFF

OFF

SPDIF OPT

SPDIF COAX or BALANCED
DIGITAL OUT