Screen Label
Description
Type
Typical Range
Units
Min
Max
FREQ IN0
Measured frequency on the
speed / tachometer input 0.
Frequency
0
6000
Hz
FREQ IN1
Measured frequency on the
speed / tachometer input 1.
Frequency
0
6000
Hz
FREQ OUT1
Output frequency of the
programmable tachometer /
speed output.
Frequency
0
6000
Hz
ENG. RPM
Measured engine speed in RPM.
Rotational Speed
0
15000
RPM
TOSS RPM
Measured transmission output
shaft or speedometer cable
speed.
Rotational Speed
0
10000
RPM
SPEED
Vehicle speed in MPH.
Speed
0
200
MPH
TPS
Throttle position in percentage.
Percentage
0
100
%
CLOCK
Running time clock.
Time
0
seconds
LK TPS
Throttle position above which
the torque converter clutch is
always unlocked.
Percentage
0
100
%
ULK TPS
Throttle position below which
the torque converter clutch is
always unlocked. Must be less
than LK TPS.
Percentage
0
100
%
LK SPD
Minimum speed at which the
torque converter clutch may be
locked.
Speed
30
100
MPH
ULK SPD
Speed below which the torque
converter clutch is always
unlocked. Must be less than LK
SPD.
Speed
30
100
MPH
LK DLY
Time, in seconds, after 4th gear
engagement, to allow torque
converter clutch actuation.
Time
0
2.5
seconds
TPS VOLT
Voltage on the throttle position
sensor.
Voltage
0
5
Volts