19
EN
(6) Cleaning and maintenance
After every use
, please check the unit for:
Damage to housing or supply lines
Damage to connection plug
Damage to security gates
Dirt on ventilation grates
At least once a year,
please check the unit for:
Function of the safety temperature limiter
Cleanliness of the switch cabinet including electric components
General visual inspection
ATTENTION:
Please observe the obligation to carry out the German BGVA3 test for commercial users according to
the professional associations at least once a year.
Cleaning
For cleaning dusty electric components we recommend blow out by compressed air.
Metal components can be cleaned with HEYLO special cleaner Art. No. 1800105.
Plastic components can be cleaned with HEYLO special cleaner Art. No. 1800104.
ATTENTION:
By no means must the electric components have contact to water or chemical cleaners.
(7) Optional accessories
Description
HEYLO Art. No.
Hot air hose - diam. 305 mm (for DE20S)
1250067
Hot air hose incl. transport bag - diam. 305 mm (for DE20S)
1250050
Room ther5 deg. C to +30 deg. C IP 20
1430003
Room ther5 deg. C to +30 deg. C IP 20 with plug and cable
1240075
Room thermostat -10 deg. C to +40 deg. C IP 54
1430033
Room thermostat -10 deg. C to +40 deg. C IP 54 with plug and cable
1240100
Thermostat connection plug
1450914
HEYLO POWER CLEAN plastic cleaner
1800104
HEYLO POWER CLEAN metal cleaner
1800105